Fluke 97 ScopeMeter 2 Channel ScopeMeter, 50 MHz
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- Fluke 97 ScopeMeter 50MHz Oscilloscope (BC# 35842-L/T*)
- (2) Fluke Flexible Test Leads
- (2) Fluke Test Pins
- (2) Fluke Alligator Clips
- Optical Interface Cable
- (2) 10:1 250Mhz Voltage Probe Sets
- AC Adapter/Charger
- User manual On CD-ROM
- Carrying Case (G)
Fluke 97 Scopemeter
NEW FUNCTIONS WITH VERSION 4 SOFTWARE
Your ScopeMeter now includes with the latest software release V4. You will find several new functions that are not described. The following list gives the most important changes:
IMPROVED USER INTERFACE
Improved accessibility of the alert function. Switching between METER mode and SCOPE mode no longer influences the original display. Pressing the METER key a second time results in the main meter display.
30Ω RANGE, 0.01Ω RESOLUTION
The 30-Ω range is accessible only in manual Range Mode. Maximum reading: 99.99Ω, Accuracy: ±2.5% ±25 counts.
INVERT WAVEFORM IN BOTH CHANNELS
Channel A can now be inverted just like Channel B.
MORE FREQUENCY COUNTER RESOLUTION
Increased frequency counter resolution to four full digits.
RECORD MODE MIN MAX TIME STAMP (MODELS 95 & 97)
Recording of MINIMUM, MAXIMUM and AVERAGE values are displayed with the time they occurred. This time stamp is related to the start of the recording and is displayed beside the actual measurement value.
Specifications:
MULTIMETER | |
DC Volt | Ranges: 300 mV, 3V, 30V, and 300V Accuracy: ±0.5% ±5 counts |
AC Volt | Ranges: 300 mV, 3V, 30V and 250V Accuracy: ±1% ±10 counts, 50 Hz to 60 Hz ±2% ±15 counts, 20 Hz to 20 kHz ±3% ±20 counts, 5 Hz to 1 MHz Additional error ±1% >1 kHz Accuracy valid from 5% to 100% of range For <10 Hz with 10:1 probe or <100 Hz direct (1:1 probe), use function Vrms AC + V DC |
mV DC | Ranges: 300 mV and 3V Accuracy: ±0.5% ±5 counts This range has a low=pass filter with a bandwidth of 5 kHz |
Ω | Ranges: 300Ω, 3 kΩ, 30 kΩ, 300 kΩ, 3 MΩ and 30 MΩ Accuracy: ±0.5% ±5 counts Range: 30Ω Accuracy: ±2.5% ±25 counts |
Diode | Measuring Current: 0.5 mA Maximum Voltage: 4V |
Display Modes | |
Frequency | The frequency can be displayed within the following parameters: Range: 1 Hz ... 5MHz Accuracy: ±0.5% Resolution: 4 digits |
Trace Display | The display trace can be switched off |
Duty%+, Duty%- | Relative on-to-off time of a varying input can be displayed as a percentage Range: from <2.0% to >98.% for signal amplitudes >10% of the input voltage range. Resolution: 0.1% Accuracy ( Logic or pulse waveforms): Within ±0.5% Accuracy (Sine or triangle waveforms): Within ±1% + ((Voltage Range/RMS Input Voltage) x 1%) |
%DELTA | Displays the difference after 0% or % Δ is pressed |
SCALING | 0% and 100% can be set as scale reference, and x is the measured value referred to 0%. |
VOLT MATH | Results can be displayed in DBV, dBm, dBW, or Audio Watt. The assumed load resistance can be chosen from: 1, 2, 4, 8, 16, 50, 760, 75, 93, 110, 125, 135, 150, 200, 250, 300, 500, 600, 800, 900, 1000, or 1200Ω , depending on the display mode. |
Record | In meter Mode, the actual value is displayed simultaneously with the maximum, average, and minimum values. |
Touch Hold Feature | Can be activated by pressing HOLD |
OSCILLOSCOPE | |
Vertical System | |
DEFLECTION FACTOR | 1 mV to 100V per division (5 mV to 100V per division for Model 94) in 102-5 Sequnecy, for time base 60s/ Division to 1ms/dvision. This can be expanded by a factor of 10 with the 10:1 probe. |
Vertical Resolution | 8 bits, 25 levels per division |
DC ACCURACY | ± (2% ± 1 digit) |
Rise Time | Vertical Amplifier response limits the rise time to 7 ns. For time base settings slower than 200 ns the rise time is smaller than the sample resistance, so the measured rise time is unreliable if it is smaller than (2 x s/Div)25 |
BANDIWTH | With 10:1 probe only: > 50 MHz (-3 dB |
NONLINEARITY | Including Analog To Digital Converter, which will have no missing codes and is monotonic ±(2% ± digit) |
MOVE CONTROL RANGE | From +4 Divisions to -4 Divisions |
DC BALANCE | Base line is automatically readjusted after switching the attenuator o rac/dc/ground. |
MIN/MAX | Acquisition mode at 1 µs per division or slower on Channel A only. Pusle width for 100% probability of detections is 40 ns. |
AVERAGE | The running average can be set to 256 maximum. In Roll Mode, the average is fixed at 10. |
ZOOM | Expand or contract view centered around the 4th division, within the limits of the time base and the maximum delay. |
HORZONTAL SYSTEM | |
RANGE | 5 ns to 10 ns per division with triggered start. The Roll Mode is active from 60s to 10s per division. Single Shots are possible from 5s to 100 ns per division. For time base settings faster thana 1ms, and automatic interpolation takes place. The useful bandwidth is about 6 MHz |
GENERAL | |
Impedance: 1 M Ω // 25 pF | Maximum Voltage: 300V up to 1 MHz (Maximum allowed voltage decreases 6 dB per octave at higher frequencies) The maximum input voltage between any terminal and earth ground is 600V |
Input protection: | The inputs are protected for line voltages of 600V and surge voltages of 4 kV |
Display | |
LCD Type: | Super Twisted Nematic |
Active Area: | 240x240 pixels, diagonal of 4.7 inches (12 cm) |
Trace area: | 200x240 pixels |
INTERNAL BATTERY POWER | |
Operating Time: | Ni-Cd Pack: 4 Hours (Typical) Alkaline C-Cell: 4 Hours (KR27/50 or R-14 size can be used. ) |
Charging Time: | 16 hours (typical) While not operating |
Charging Current: | 100 mA with ScopeMeter ON 200 mA with ScopeMeter OFF |
Maximum Temperature During Charging: | 45°C |
Temperature And Humidity | |
Operating Temperature: | 0°C to 50°C |
Storage Temperature: | -20°C to 70°C |
Relative Humidity: | 90% from 20°C to 30°C 70% From 30°C to 50°C |
Shock & Vibration | |
Per MIL-T-28800 for a Class 3 instrument | |
SIZE (HxWxL) | |
ScopeMeter Only: | 60 mm x 129 mm x 262 mm (2.4 Inch x 5.1 inch x 10.3 inch) |
With Holster: | 62 mm x 140 mm x 281 mm (2.5 Inch x 5.5 inch x 11.1 inch) |
Weight: | ScopeMeter Only: 1.5 kG (3.3 lbs) With Holster: 1.8 kg (4.0 lbs) |
Safety | |
Designed to protection Class II per IEC 348 and UL1244 for 600V | |
Sealing | |
Dust and splash proof |