Fluke i430 FLEXI-TF-II 6000 A Flexible AC Current Probe
Condition: Refurbished
Warranty: 90 Day Exchange
Fluke Networks i430-Flexi-TF-II AC Current Probe
The i430-Flexi-TF-II (the Probe or Product) is a flexible AC current probe for use with the Fluke 430 series I and II Power Quality Analyzers and other dedicated test tools. The i430-Flexi-TF-II is optimized for current measurement on thick and hard to reach conductors. Check the user documentation of your test tool for compatibility before you use this current sensor.
Compatibility
The i430-Flexi-TF-II series is used with the Fluke 430-series and Fluke 430-II series Power Quality Analyzers specifically or with other test tools that explicitly state compatibility.
Specifications:
Measuring range | 0.5 A ac to 6000 A ac |
Maximum non-destructive current | 100 kA (50/60 Hz) |
Output signal | 86.6 mV at 1000 A/50 Hz (on 1 MΩ) 85.0 mV at 1000 A/50 Hz (on 50 kΩ) |
Basic accuracy | ±1 % of reading at 25 °C, 50 Hz with conductor placed at the center of the probe |
Linearity | ±0.2 % of reading at 10 % to 100 % of range |
Noise | <1 mV rms at 10 Hz to 10 kHz |
Additional errors: temperature coefficient over operating temperature range with position of conductor in the probe window: 0.5 to 30 A |
24 inch model: 0.02 % of reading / °C (0.011 % / °F) 48 inch model: 0.035 % of reading / °C (0.02 % / °F) Zone A: ±0.5 % of reading Zone B: ±1.0 % of reading Zone C: ±2.0 % of reading ±1 count or 0.1 A (whichever is greater) |
External magnetic field rejection in reference to external current | 40 dB (with cable >100 mm from the head coupling and r-coil) |
Phase shift (fundamental frequency) | <±1° |
Bandwidth (-3 dB) | 10 Hz to 10 kHz |
Frequency derating | I x f ≤385 kA Hz |
General Specifications | |
Transducer length | 61 cm (24 in) |
Weight | 153 g |
Transducer diameter | 7.5 mm (0.3 in) |
Minimum bending radius | 38 mm (1.5 in) |
Cable length from transducer to BNC | 2.5 m (98.4 in) |
Temperature, operating | -20 °C to +70 °C (-4 °F to +158 °F) Temperature of conductor under test shall not exceed 80 °C (176 °F) |
Temperature, non-operating | -40°C to + 80 °C (-40 °F to +176 °F) |
Relative Humidity, operating | 15 % to 85 %, noncondensing |
Altitude, operating | 2 000 m (6 500 ft); for use up to 4000 m derate to 300 V CAT IV, 600 V CAT III, 1000 V CAT II. |
Altitude, storage | 12 km (40 000 ft) |
Ingress protection | IP40 |
Fluke i430-FLEXI-TF-II AC Current Probe