Fluke 1730 kit with accessories

Fluke 1730 Three Phase Energy Logger

Fluke 1732 Three Phase Electrical Energy Power Logger Analyzer

Fluke 1732 Three Phase Electrical Energy Power Logger Analyzer

Fluke i430 FLEXI-TF-II 6000 A Flexible AC Current Probe

$345.00
Availability: Out of stock
SKU
11H70

Condition: Refurbished

Warranty: 90 Day Exchange

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

Fluke Networks i430-Flexi-TF-II AC Current Probe

The i430-Flexi-TF-II (the Probe or Product) is a flexible AC current probe for use with the Fluke 430 series I and II Power Quality Analyzers and other dedicated test tools. The i430-Flexi-TF-II is optimized for current measurement on thick and hard to reach conductors. Check the user documentation of your test tool for compatibility before you use this current sensor.

 

Compatibility

The i430-Flexi-TF-II series is used with the Fluke 430-series and Fluke 430-II series Power Quality Analyzers specifically or with other test tools that explicitly state compatibility.

 

Specifications:

Measuring range 0.5 A ac to 6000 A ac
Maximum non-destructive current 100 kA (50/60 Hz)
Output signal 86.6 mV at 1000 A/50 Hz (on 1 MΩ)
85.0 mV at 1000 A/50 Hz (on 50 kΩ)
Basic accuracy ±1 % of reading at 25 °C, 50 Hz with conductor placed at the center of the probe
Linearity ±0.2 % of reading at 10 % to 100 % of range
Noise <1 mV rms at 10 Hz to 10 kHz
Additional errors:
temperature coefficient over operating temperature range
with position of conductor in the probe window:


0.5 to 30 A
24 inch model: 0.02 % of reading / °C (0.011 % / °F)
48 inch model: 0.035 % of reading / °C (0.02 % / °F)
Zone A: ±0.5 % of reading
Zone B: ±1.0 % of reading
Zone C: ±2.0 % of reading
±1 count or 0.1 A (whichever is greater)
External magnetic field rejection in reference to external current 40 dB (with cable >100 mm from the head coupling and r-coil)
Phase shift (fundamental frequency) <±1°
Bandwidth (-3 dB) 10 Hz to 10 kHz
Frequency derating I x f ≤385 kA Hz
General Specifications
Transducer length 61 cm (24 in)
Weight 153 g
Transducer diameter 7.5 mm (0.3 in)
Minimum bending radius 38 mm (1.5 in)
Cable length from transducer to BNC 2.5 m (98.4 in)
Temperature, operating -20 °C to +70 °C (-4 °F to +158 °F) Temperature of conductor under test shall not exceed 80 °C (176 °F)
Temperature, non-operating -40°C to + 80 °C (-40 °F to +176 °F)
Relative Humidity, operating 15 % to 85 %, noncondensing
Altitude, operating 2 000 m (6 500 ft); for use up to 4000 m derate to 300 V CAT IV, 600 V CAT III, 1000 V CAT II.
Altitude, storage 12 km (40 000 ft)
Ingress protection IP40
For full Fluke i430 FLEX-TF-II AC Current Probe product specifications, please click here: Fluke i430 FLEX-TF-II

Fluke i430-FLEXI-TF-II AC Current Probe

Used with the Fluke 430-series and Fluke 430-II series Power Quality Analyzers specifically or with other test tools that explicitly state compatibility

BC# 37859-L/T*