Fluke Networks MFTK1200 MM MPO Fiber Loss Test Kit

$3,495.00
Availability: In stock
SKU
4H137

Condition: Refurbished

Warranty: 1 YEAR WARRANTY

Fluke Networks MultiFiber Pro
MultiFiber Pro takes the complexity out of testing MPO trunks for loss and polarity. With an on-board MPO connector, it is the first tester to automate the MPO fibertrunk testing process without using a fan-out cord. The power meter/light source boasts industry-first functions such as automatic scanning of all twelve fibers and display of test results in an easy-to-read bar graph. These innovative features allow MultiFiber Pro kits to eliminate the complexity of testing MPO trunks, making it 90 percent faster than the traditional simplex test methods.

First MPO tester to support both Singlemode and Multimode MPO fiber testing
Data centers are growing, fueled by the proliferation of media, virtualization and the need for more security and storage. This creates a high demand for 40 Gbps+ fiber links. Whether it is using 10 Gbps pre-terminated fiber trunks or planning for next-generation 40/100 Gbps performance, data centers are standardizing on Multi-fiber Push-on (MPO) connector solutions.

Pre-terminated fiber cables are manufactured and tested to comply with ANSI/TIA and international standards. When these cables are installed many factors can potentially impact performance. Field testing is the only way to ensure that pre-terminated fiber is installed to meet the application performance requirements. With single and duplex testers this verification testing is a timeconsuming, manual and imprecise process. To ensure installation is done to standards, test with the MultiFiber Pro.

MultiFiber Pro Power Meter and Light Source feature the following:

  • Automatic scanning and testing of all fibers in MPO connectors with “Scan All”
  • Support for both Multimode and Singlemode MPO trunks
  • Eliminates the need for fan-out cords when testing fiber trunks
  • Easy to interpret test results with minimal navigation
  • User interface displays all 12 fibers
  • Automate 8, 10 and 12 fiber measurements
  • Troubleshoot MPO links and drill down to single fiber test results
MultiFiber Pro Unique Capabilities

“SCAN ALL” Function
Scan All function in the MultiFiber Pro Power Meter automatically scans and tests all 12 fibers in MPO connectors – taking just 6 seconds to complete all loss or power measurements. This feature automates the testing of MPO terminated fibers and eliminates the time consuming and manual process of moving the tester from fiber to fiber while using fan-out cords.

Built-in Polarity Verification
The simple purpose of any polarity scheme is to provide a continuous connection from the link's transmitter to the link's receiver. For array connectors, TIA-568-C.0 defines three methods to accomplish this. Deployment mistakes are common because these methods require a combination of patch cords with different polarity types. The polarity measurement of MultiFiber Pro allows the user to test individual patch cords, permanent links, and channels for correct polarity.

Polarity Agnostic Referencing
MPO deployments have many possible polarities: A, B, C, and Universal. MultiFiber Pro utilizes the concept of polarity agnostic referencing to simplify the referencing step. This powerful feature allows the user to reference with any polarity of patch cord. Then, using those same patch cords, the user can test any polarity link. Prior knowledge of the link's polarity is not required.

On-board MPO connector
The MPO connector on both the Optical Power Meter and Light Source eliminates the use of costly and complicated fan-out cords to test MPO fiber trunks.

Simple User Interface
The MultiFiber Pro simplifies the task of simultaneously presenting polarity, power, and loss results for 12 fibers. The power meter enables the users to easily comprehend the measurement results of 12 fibers simultaneously. The light source identifies each fiber within the MPO connector being tested. Any individual measurements that fail the test limit is identified to allow root-cause analysis. This powerful yet straightforward test set enables everyone to become a fiber testing expert increasing efficiency in testing data center projects.

Select an Individual Fiber
Drilling down to a single fiber during testing and troubleshooting is always a challenge in data centers. MuliFiber Pro can troubleshoot a single fiber within an MPO trunk to provide a single fiber test result. This increases MPO connector verification and troubleshooting flexibility with more precise, per-fiber data and reporting.

Easy Reporting
The MultiFiber Pro Power Meter stores up to 3,000 test results internally which can be uploaded to a PC using the LinkWare™ Cable Test Management Software. LinkWare allows you to manage test results, edit cable ID's, print professional reports and even export the data into spreadsheet formats.

Kits for Every Need
MultiFiber Pro is available in several convenient kit configurations to meet all your cleaning, inspection and verification testing needs. Some kits include:

FI-7000 FiberInspector Pro with MPO tip and cleaning supplies
The FI-7000 is the ultimate inspection tool. It enables you to quickly inspect and certify fiber endfaces inside ports or patch cords. It’s 2-second automated PASS/FAIL eliminates human subjectivity and enables anyone to become a fiber inspection expert.
  • Automated Pass/Fail acceptance testing of fiber end-faces
  • Large touchscreen for pinch and zoom
  • Graphical indication of problem areas due to contamination, pits, chips, and scratches
  • Certify to industry standards – IEC 61300-3-35
  • Eliminate human subjectivity from end-face measurements
  • Includes MPO tip for inspection probe and MPO cleaner
Fiber Cleaning – Quick Clean™ Cleaners
Cleaning is critical. Fluke Networks' Quick Clean Cleaners instantly clean fiber optic bulkhead connectors and end-faces. Just push the tool tip to engage cleaning action and pull back on the wheel – it’s that simple. The MPO Quick Clean Cleaner is bundled with the MultiFiber Pro kits to ensure that you have the best cleaning tool from the beginning.

Specifications:
Environmental
Operating temperature -10° C to +50° C
Storage temperature -20° C to +50° C
Operating humidity 95% (10° C to +35° C) non-condensing
75% (35° C to +45° C) non-condensing
Uncontrolled < 10° C
Operating altitude 12,000 m
Storage altitude 12,000 m
Vibration Random 2 G, 5 Hz to 500 Hz
Optical Power Meter (Specifications apply at 23° C (73° F), unless otherwise noted.)
Detector type InGaAs
Calibrated wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm
Measurement Range 0 dBm to -50 dBm
Test time 6 seconds
Power measurement linearity ±0.1 dB
Power measurement uncertainty ±0.35 dB
Power measurement repeatability < 0.10 dB
Display resolution, dB or dBm 0.01
Power display units dBm, mW, µW
User-selectable limit for loss 0.05 dB to 50.0 dB, in increments of 0.05 dB up to 10.0 dB and 0.1 dB up to 50.0dB
Auto wavelength detection Yes
Polarity detection Detects A, B, C, and Corning Plug & Play™ Universal Systems polarities
2 kHz detection Yes
Record storage 3000 records, one fiber per record (250 12-fiber cables)
External interface USB 2.0, full speed
Optical connector MPO interface for 12-fiber, unpinned plugs. Compatible with 62.5 µm, 50 µm, and singlemode fibers. Connector has a self-closing, protective cover
Power requirement 2 AA alkaline batteries
Battery life 30 hours (typical)
Automatic power-off 10, 20, 30, or 60 minutes (can be disabled by the user)
Low battery warning Low battery icon blinks
Size 5.8 in x 3.2 in x 1.6 in (14.7 cm x 8.0 cm x 4.0 cm)
Weight 10.9 oz (309 g)
850 nm Source
Emitter type LED
Wavelength ±30 nm
Spectral width (FWHM) 50 nm (typical)
Minimum output power ≥ -24 dBm
Power output stability ≤±0.1 dB over 8 hours 4
Laser safety IEC 60825-1:Class 1
Encircled flux Meets TIA 455-526-14B, ISO/IEC 14763-3, and IEC 61280-4-1 for 50/125 µm at the source’s optical connector.
Optical connector MTP/MPO interface for 12-fiber, unpinned plugs. Compatible with 62.5 µm and 50 µm fibers, nonAPC only. Connector has a selfclosing, protective cover.
Modes 2 kHz modulated, auto wavelength/td>
Power requirement 2 AA alkaline batteries
Battery life6 >30 hours (typical)
Automatic power-of 10, 20, 30, or 60 minutes (can be disabled by the user)
Low battery warning Low battery icon blinks
Size 5.8 in x 3.2 in x 1.6 in (14.7 cm x 8.0 cm x 4.0 cm)
Weight 11.4 oz (323 g)




For full Fluke Networks MFTK1200 product specifications, please click here: Fluke Networks MFTK1200

Fluke Networks MFTK1200 MM 850nm MPO Fiber Loss Test Set
Fluke Networks MultiFiber Pro MM 850nm Fiber Source w/
Fluke Networks MultiFiber Pro SM MM Fiber Power Meter

Power Meter:
- 850nm
- 1300nm
- 1310nm
- 1550nm

Includes Carrying Case & Accessories As Listed 

MFTK-1200 MFTK 1200

Fluke Networks MFTK1200 MFTK-1200 MultiFiber Pro MPO Test Set Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 34486 33718

  • Fluke Networks MultiFiber Pro MM Fiber Source (BC# 34486-L/T*)
    • MM Source:
      • 850nm
  • Fluke Networks MultiFiber Pro Power Meter (BC# 33718-L/T*)
    • Power Meter:
      • 850nm
      • 1300nm
      • 1310nm
      • 1550nm
  • (2) Fluke Networks 4163829 Cables
  • Fluke Networks 4163852 Cable
  • Fluke Networks 4163865 Cable
  • (2) Fluke Networks 4176337 Adapters
  • MultiFiber Pro Getting Started Guide
  • MultiFiber Pro Product Information Guide
  • USB PC Interface Cable
  • Carrying Case w/ Strap