  • Fluke Ti27 Infrared Thermal Imager (BC# 27781-L/T*) 
  • Fluke TiSBC3 Battery Charger w/ AC Adapter
  • Fluke Delkin Hi Speed Render
  • 2GB SD Card
  • Fluke SmartView Software
  • (2) Battery Packs
  • DC Car Charger
  • Hard Copy User Manual
  • User Manual On CD-ROM
  • Hard Carrying Case
  • Carrying Case
Request a Quote for

Have questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

We are commited to win your business!

 
Due to strict commerce control regulations, AAATesters does not ship or export Thermal Imagers to any countries outside of the United States.
International customers, please note that we cannot complete any order that includes a Thermal Imager product. AAATesters cannot complete any sale where the intent may be that a Thermal Imager product may be exported internationally by the end user.
All customers that are purchasing Thermal Imager products from AAATesters will be required to complete a BIS-711 end use agreement form to ensure that the Thermal Imager product will not be exported internationally.


 

Fluke Ti27 Industrial Thermal Imager
Designed for industrial and commercial environments, the Fluke Ti27 delivers superior image quality, versatility, and affordability without compromise. The Fluke Ti27 boasts 240x180 infrared resolution, industry leading spatial resolution, and a high definition display creating the sharpest images in its price class. Finding a potential problem before it becomes a costly disaster shows you just how much a Fluke thermal imager can save you in time, money and even lives.

The greatest technological advancement in thermography may be how Fluke has made it so simple to capture images and analyze data right out of the box. With just a push of your thumb, go from one handed manual smart focus to adding picture-in-picture and even add comments in your own voice.

The Fluke Ti27 also offers the only on-camera blended infrared with patented Fluke IR-Fusion® technology precisely aligning visible and IR images to better diagnose issues.

Features:

  • Superior image quality
    • Delivers the clear, crisp images needed to find problems fast with its 240x180 infrared resolution.
    • Identify even the smallest temperature differences that could indicate problems with industry-leading thermal sensitivity (NETD).
    • Automatic alignment (parallax correction) of visual and infrared images with Fluke patented IR-Fusion®
    • Optional telephoto and wide angle lenses available for added versatility and special applications. (easily installable in the field)
  • Easy To Use
    • Field replaceable batteries give you maximum flexibility no matter where your work takes you.
    • Intuitive, three-button menu is easy to useラsimply navigate with the push of a thumb.
    • No need to carry pen and paperラrecord findings by speaking into the imager. Voice annotations can be recorded with every image you take. Voice comments are saved along with individual images for future reference.
    • One-handed focus capability, emissivity correction, reflected background temperature compensation, and transmission correction increase the accuracy of measurements in most situations.
    • Adjustable hand strap for left-or right-handed use.
  • Rugged
    • Optimized for field use in challenging work environments.
    • Engineered and tested to withstand a 2 m drop for the ultimate peace of mind - When was the last time you dropped a tool or piece of equipment?
    • Withstands dust and waterラtested to an IP54 rating.


Specifications:

 
Temperature
Temperature measurement range (not calibrated below -10 °C) -20 °C to +600 °C (-4 °F to +1112 °F)
Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
On-screen emissivity correction Yes
On-screen reflected background temperature compensation Yes
On-screen transmission correction Yes
Imaging performance
Image capture frequency 9 Hz refresh rate or 60 Hz refresh rate depending upon model variation
Detector type Focal Plane Array, uncooled microbolometer, 240 x 180 pixels
Total pixels 43,200
Thermal sensitivity (NETD) = 0.05 °C at 30 °C target temp. (50 mK)
Infrared spectral band 7.5 µm to 14 µm (long wave)
Visual (visible light) camera Industrial performance 2.0 megapixel
Minimum focus distance 46 cm (approx. 18 in)
Standard infrared lens type
  • Field of view : 23 ° x 17 °
  • Spatial resolution (IFOV) : 1.67 mRad
  • Minimum focus distance : 15 cm (approx. 6 in)
Optional telephoto infrared lens type
  • Field of view : 11.5 ° x 8.7 °
  • Spatial resolution (IFOV) : 0.84 mRad
  • Minimum focus distance : 45 cm (approx. 3 in)
Optional wide-angle infrared lens type
  • Field of view : 46 ° x 34
  • Spatial resolution (IFOV) : 3.34 mRad
  • Minimum focus distance : 7.5 cm (approx. 3 in)
Focus mechanism Manual, one-handed Smart Focus capability
Image presentation
Palettes
  • Standard: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
  • Ultra Contrast, Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber  Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grascale Inverted Ultra
Level and span Smooth auto-scaling and manual scaling of level and span
Fast auto toggle between manual and auto modes Yes
Fast auto-rescale in manual mode Yes
Minimum span (in manual mode) 2.5 °C (4.5 °F)
Minimum span (in auto mode) 5 °C (9 °F)
IR-Fusion® information
Automatically aligned (parallax corrected) visual and IR blending Yes
Picture-In-Picture (PIP) Three levels of on-screen IR blending displayed in center of LCD
Full screen infrared Three levels of on-screen IR blending displayed in center of LCD
Color alarms (temperature alarms)    High-temperature color alarm (user-selectable)
Image capture and data storage
Image capture, review, save mechanism The Ti27 allows user to adjust palette, blending, level, span, IR-Fusion® mode, emissivity, and reflected background temperature compensation, and transmission correction on a captured image before it is stored.
Voice annotation 60 seconds maximum recording time per image; reviewable playback on imager
Storage medium One-handed image capture, review, and save capability
File formats SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations, or 3000 basic bitmap (.bmp) images, or 3000 jpeg (.jpeg) images; transferrable to PC via included multi-format USB card reader
Export file formats w/SmartView® software
  • Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2)
  • No analysis software required for non-radiometric (.bmp and .jpeg files)
General specifications
Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature -20 °C to +50 °C (-4 °F to 122 °F) without batteries
Relative humidity 10 % to 95 % non-condensing
Display 9.1 cm (3.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight and clear protective cover
Controls and adjustments
  • User selectable temperature scale (°C/°F)
  • Language selection
  • Time/Date set
  • Emissivity selection
  • Reflected background temperature compensation
  • Transmission correction
  • User selectable hot spot and cold spot, and center point on the image (other custom markers and shapes in SmartView® software)
  • High temperature color alarm
  • User selectable backlight: モFull Bright or モAuto
  • Information display preference
Software SmartView® full analysis and reporting software included
Batteries Two lithium ion rechargeable smart battery packs with five-segment LED display to show charge level
Battery life Four+ hours continuous use per battery pack (assumes 50 % brightness of LCD)
Battery charge time 2.5 hours to full charge
AC battery charging Two-bay ac battery charger (110 V ac to 220 V ac, 50/60 Hz) (included), or in-imager charging. AC mains adapters included. Optional 12 V automotive charging adapter.
AC operation AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz). AC mains adapters included.
Power saving Sleep mode activated after five minutes of inactivity, automatic power off after 30 minutes of inactivity
Safety standards IEC 61010-1: Cat None, Pollution degree 2
Electromagnetic compatibility Meets all applicable requirements in EN61326-1:2006
C Tick IEC/EN 61326-1
US FCC CFR 47, Part 15 Class B
Vibration 0.03 g2/Hz (3.8 grms), IEC 68-2-6
Shock 25 g, IEC 68-2-29
Drop 2 meter (6.5 feet) with standard lens
Dimensions (H x W x L) 27.7 cm x 12.2 cm x 17.0 cm (10.9 in x 4.8 in x 6.7 in)
Weight (battery included) 1.05 kg (2.3 lb)
Enclosure rating IP54 (protected against dust, limited ingress; protection against water spray from all directions)