Fluke Ti45FT-20 FlexCam IR Thermal Imager Ti45
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA Only
- Fluke Ti45FT-20 Infrared Thermal Imager (BC# 40420-L/T*)
- 20mm F/0.8 8-14 µm Lens
- AC Adapter & Power Cord
- USB PC Interface Cable
- User Manual On CD-ROM
- Carrying Case (G)
Due to strict commerce control regulations, AAATesters does not ship or export Thermal Imagers to any countries outside of the United States. |
International customers, please note that we cannot complete any order that includes a Thermal Imager product. AAATesters cannot complete any sale where the intent may be that a Thermal Imager product may be exported internationally by the end user. |
All customers that are purchasing Thermal Imager products from AAATesters will be required to complete a BIS-711 end use agreement form to ensure that the Thermal Imager product will not be exported internationally. |
Fluke Ti45FT Infrared Thermal Fusion IR Imager
Highlights
- High resolution, low noise VOx detector for high quality images - 160 x 120
- Temperature range -20 °C to +600 °C (-4 °F to 1112 °F)
- Thermal Field of view - 20 mm lens 23 ° x 17 ° FOV
- The Fluke Ti45FT models feature everything needed for virtually any thermography task
- All Fluke FlexCam Thermal Imagers come standard with the patent-pending Fluke IR-Fusion® Technology fusing visual (visible light) images with infrared images
- Choose Fluke FlexCam Thermal Imagers when you need industry leading thermal sensitivity for high resolution, ultra high-quality images
- Troubleshooting ラ Pinpointing the location of specific problems in equipment and systems
- Preventive/predictive maintenance ラ Identify electrical and mechanical problems before they cause failure
- Industrial maintenanceラCheck whether repairs have been performed correctly
- Process monitoringラReal-time observation to ensure efficient and safe operations
- Quality controlラExamine prototypes and refine thermal management designs
Typical applications:
- Predictive maintenance ヨ Identify electrical and mechanical problems before they cause failure
- Industrial maintenance ヨ Check whether repairs have been performed successfully
- Quality control ヨ Examine prototypes and refine thermal management designs
- Process monitoring ヨ Real-time observation to ensure efficient and safe operation
The Fluke Ti45FT models feature everything needed for virtually any thermography task. The Ti45FT offer many options that the Ti45 does not have, such as:
- Built-in visible light camera
- IR-Fusion blending thermal and visible light images to easily pinpoint suspect components
- IR/Visible Alarm Function
- Laser pointer for easy targeting
- Flash and torch light for high quality images in dark environments
All Fluke FlexCam Thermal Imagers come standard with the patent-pending Fluke IR-Fusion® Technology fusing visual (visible light) images with infrared images. SmartViewル IR analysis and reporting software is included with each purchase along with free software upgrades for the life of your product.
The Ti45FT models feature 160 x 120 detectors and temperature sensitivity (NETD) down to 0.08 °C (80 mK) in the higher end model.
Choose Fluke FlexCam Thermal Imagers when you need industry leading thermal sensitivity for high resolution, ultra high-quality images.
Imaging performance | |
Field of view (FOV) | 23チヒ horizontal x 17チヒ vertical |
Spatial resolution (IFOV) | 2.60 mrad |
Min focus distance | 0.15 m (5.9 in) |
Thermal sensitivity (NETD) | = 0.08 °C at 30 °C (80mK) |
Detector data acquisition/ image frequency | 7.5Hz/7.5Hz |
Focus | SmartFocus; one finger continuous focus (manual) |
IR digital zoom | 2x |
Detector type | 160 x 120 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer |
Spectral band | 8 µm to 14 µm |
Digital image enhancement | Automatic full time enhanced |
On camera operating modes | Full thermal, full visual light or merged thermal-visual images. Picture-in-Picture |
Visible light camera | 1280 x 1024 pixels, full color |
Visible light digital zoom | 2x |
Temperature measurement | |
Calibrated temperature range | -20 °C to 600 °C (-4 °F to 1112 °F) in three ranges Range one = -20 °C to 100 °C (-4 °F to 212 °F) Range two = -20 °C to 350 °C (32 °F to 662 °F) Range three = 250 °C to 600 °C (482 °F to 1112 °F) |
Optional.High temperature | Up to 1200 °C (2192 °F) Range 4 = 500 °C to 1200 °C (932 °F to 2192 °F) |
Accuracy | チ± 2 °C or 2 % (whichever is greater) |
Measurement modes | Centerpoint, center box (area min/max, average), moveable spots/boxes, user defined field/text annotations, automatic hot and cold point detection, visible color alarm above and below |
Emissivity correction | 0.1 to 1.0 (0.01 increments) |
Image presentation | |
Digital display | 13 cm (5 in) diagonal large high-resolution digital display |
LCD backlight | Sunlight readable color LCD |
Video output | RS170 EIA/NTSC or CCIR/PAL composite video |
Palettes | Grayscale, grayscale inverted, blue red, high contrast, hot metal, ironbow, amber, amber inverted |
Optical lenses | |
54 mm telephoto lens | High precision Germanium lens Field of view (FOV): 9° horizontal x 6° vertical |
Spatial resolution (IFOV): 0.94 mrad | |
Min focus distance: 0.6 m (1.97 ft) |
For full Fluke Ti45FT specifications, please click here: Fluke Ti45FT