Fluke Ti9 9Hz 160 x 120 Infrared Thermal Imager
$899.00
Availability:
In stock
SKU
Ti103
Condition: Refurbished / Calibrated
Warranty: 1 Year Warranty
Shipping: USA Only
- Fluke Ti9 Infrared Thermal Imaging Camera (BC# -L/T*)
- Battery Pack
- User Manual On CD-ROM
- Carrying Case
Request a Quote for
Due to strict commerce control regulations, AAATesters does not ship or export Thermal Imagers to any countries outside of the United States. |
International customers, please note that we cannot complete any order that includes a Thermal Imager product. AAATesters cannot complete any sale where the intent may be that a Thermal Imager product may be exported internationally by the end user. |
All customers that are purchasing Thermal Imager products from AAATesters will be required to complete a BIS-711 end use agreement form to ensure that the Thermal Imager product will not be exported internationally. |
Fluke Ti9 Infrared Thermal Imaging Camera
The Fluke Ti9 Thermal Imager is an entry-level thermal imager that offers a superior image quality, unmatched ruggedness, and unique ease-of-use at a breakthrough price point for the facilities maintenance professional, commercial or residential electrician, and HVAC/R professional.
- Optimized for field use in harsh work environments
- Engineered and tested to withstand a 2 m (6.5 ft) drop
- Withstands dust and water—tested to an IP54 rating.
- Delivers the clear, crisp images needed to find problems fast.
- Identify even small temperature differences that could indicate
problems with excellent thermal sensitivity (NETD).
- Intuitive, three-button menu is easy to use
- simply navigate with the push of a thumb.
Specifications:
Temperature | |
Temperature measurement range (not calibrated below -10 °C) | -20 °C to +250 °C (-4 °F to +482 °F) |
Temperature measurement accuracy | ± 5 °C or 5 % (at 25 °C nominal, whichever is greater) |
On-screen emissivity correction | In software only |
On-screen reflected background temperature compensation | In software only |
Imaging performance | |
Image capture frequency | 9 Hz refresh rate |
Detector type | 160 X 120 Focal Plane Array, uncooled microbolometer |
Thermal sensitivity (NETD) | ≤ 0.20 °C at 30 °C target temp. (200 mK) |
Visual (visible light) camera | No visible camera |
Infrared field of view | 23 ° x 17 ° |
Spatial resolution (IFOV) | 2.5 mRad |
Minimum infrared focus distance | 15 cm (approx. 6 in) |
Focus mechanism | Manual, one-handed Smart Focus capability |
Image capture and data storage | |
Image capture, review, save mechanism | One-handed image capture, review, and save capability |
Storage medium | SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations (when available), or 3000 basic bitmap (.bmp) images transferrable to PC via included multi-format USB card reader |
File formats | Non-radiometric (.bmp) or
fully-radiometric (.is2)
No analysis software required for non-radiometic bitmap (.bmp) files |
Export file formats w/SmartView® software | BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF |
Memory review | Sequential image navigation and review |
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to +50 °C (-4 °F to 122 °F) without batteries |
Relative humidity | 10 % to 95 % non-condensing |
Display | 9.1 cm (3.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight and clear protective cover |
Controls and adjustments | User selectable temperature
scale (°C/°F)
Language selection Time/Date set Emissivity selection (Ti25 only) Reflected background temperature compensation (Ti25 only) User selectable hot spot and cold spot, and center point on the image (Ti25 only) (other custom markers and shapes in SmartView® software) User selectable backlight: “Full Bright” or “Auto” |
Software | SmartView® full analysis and reporting software included |
Batteries | Internal rechargeable battery pack (included) |
Battery life |
Three to four hours continuous use (assumes 50 % brightness of LCD) |
Battery charge time |
2.5 hours to full charge |
AC battery charging |
AC adapter/charger (110 V ac to 220 V ac, 50/60 Hz) (included), charges battery while imager is operating or turned off, ac mains adapters included |
AC operation |
AC operation with included power supply (110 V ac to 220 V ac, 50/60 Hz). AC mains adapters included. |
Power saving |
Sleep mode activated after five minutes of inactivity, automatic power off after 30 minutes of inactivity |
Safety standards |
CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01 |
Electromagnetic compatibility |
Meets all applicable requirements in EN61326-1:2006 |
C Tick |
IEC/EN 61326-1 |
US FCC |
CFR 47, Part 15 Class B |
Vibration |
0.03 g2/Hz (3.8 grms), IEC 68-2-6 |
Shock |
25 g, IEC 68-2-29 |
Drop |
2 meter (6.5 feet) |
Size (H x W x L) |
26.7 cm x 12.7 cm x 15.2 cm (10.5 in x 5.0 in x 6.0 in) |
Weight (battery included) |
1.2 kg (2.6 lb) |
Enclosure rating |
IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Recommended calibration cycle |
Two-years (assumes normal operation and normal wear) |
Supported languages |
Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
For full Fluke Ti9 Thermal Imager product specifications, please click here: Ti9