Fluke Ti95 9Hz Infrared Thermal Imager
$889.00
Availability:
In stock
SKU
Ti76
Condition: Refurbished / Calibrated
Warranty: 1 Year Warranty
Shipping: USA Only
- Fluke Ti95 Infrared Thermal Imager (BC# 30926-L/T*)
- Fluke Wireless 8GB SD Card
- AC Adapter/Charger w/ (3) Adapters
- USB PC Interface Cable
- User Manual On Cd-ROM
- Carrying Case (G)
Request a Quote for
Due to strict commerce control regulations, AAATesters does not ship or export Thermal Imagers to any countries outside of the United States. |
International customers, please note that we cannot complete any order that includes a Thermal Imager product. AAATesters cannot complete any sale where the intent may be that a Thermal Imager product may be exported internationally by the end user. |
All customers that are purchasing Thermal Imager products from AAATesters will be required to complete a BIS-711 end use agreement form to ensure that the Thermal Imager product will not be exported internationally. |
Fluke Ti95 Thermal imager
Fluke Infrared Cameras Experience. Performance. Confidence.
The Fluke Performance Series Infrared Cameras can save you time and money by finding potential problems before they become costly failures.
- Fluke Connect™ ShareLive™ video call lets you collaborate with others, so they see what you see. Get approvals without leaving the field1
- Precisely blended visual and infrared images with crucial details to assist in identifying potential problems – IR-Fusion® technology with AutoBlend™ mode
- Easily see potential problems with the large 3.5 inch LCD, a full 32% larger than many competitive models
- Automatically focus from 1.2 m (4 ft) and beyond with IR-OptiFlex™ Focus System and as close as 15 cm (6 in) in manual mode
- Building diagnostic models – get 20% better thermal sensitivity (80 mK) with a lower temperature range with TiR models (TiR125, TiR110, TiR105) compared to standard Ti125, Ti110 and Ti105 models
IR-Fusion® Technology with AutoBlend™ Mode
Precisely blended visual and infrared images with crucial details to assist in identifying potential problems.
Specifications:
IFOV (spatial resolution) | 5.6 mRad |
Detector resolution | 80x80 (6,400 pixels) |
Field of view | 26 °H x 26 °V |
Wireless connectivity | Yes |
Fluke Connect™ app compatible | Yes, with included wireless SD card (where available) |
CNX™ Wireless System | No |
IR-Fusion® technology | |
AutoBlend™ mode | No |
Picture-In-Picture (PIP) | Max IR PIP |
Focus system | Fixed focus Minimum focus distance, 46 cm (18 in) |
Ruggedized display | 3.5 inch diagonal (portrait format) |
Rugged, ergonomic design for one-handed use | Yes |
Thermal sensitivity (NETD) | ≤ 0.10 °C at 30 °C target temp (100 mK) |
Temperature measurement range (not calibrated below -10 °C) | -20 °C to +250 °C (-4 °F to +482 °F) |
Level and span | Smooth auto and manual scaling |
Fast auto toggle between manual and auto modes | Yes |
Fast auto-rescale in manual mode | Yes |
Minimum span (in manual mode) | 2.5 °C |
Minimum span (in auto mode) | 5 °C |
Built-in digital camera (visible light) | 2 megapixel industrial performance |
Frame rate | 9 Hz only |
Data storage and image capture | |
Extensive SD memory system | Removable SD memory card and wireless SD card (where available); direct download via USB-to-PC connection |
Image capture, review, save mechanism | One-handed image capture, review, and save capability |
File formats image | Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); No analysis software required for non-radiometric (.bmp, .jpg) files |
Memory review | Thumbnail view navigation and review selection |
Software | SmartView® software, Fluke Connect™ (where available), and SmartView® Mobile App—full analysis and reporting software |
Export file formats with SmartView® software | BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF |
Battery | |
Battery charge time | 2.5 hours to full charge |
Battery charging system | In-imager charging. Optional two-bay battery charger or optional 12 V automotive charging adapter |
AC operation | AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) |
Power saving | User selectable sleep and power off modes |
Temperature measurement | |
Accuracy | ± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
On-screen emissivity correction | Yes (both value and table) |
On-screen reflected background temperature compensation | Yes |
Color palettes | |
Standard palettes | 6: Ironbow, BlueRed, High-Contrast, Amber, Hot Metal, Grayscale |
General specifications | |
Infrared spectral band | 9 µm to 15 µm (long wave) |
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to +50 °C (-4 °F to 122 °F) |
Relative humidity | 10 % to 95 %, non-condensing |
Center-point temperature measurement | Yes |
Spot temperature | Hot and cold spot markers |
Center box | Fixed-size measurement box with MIN-MAX-AVG temp |
Safety standards | CSA: C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01 |
Electromagnetic compatibility | EN 61326-1:2006 IEC 61326-1:2005 |
C Tick | IEC/EN 61326-1 |
US FCC | EN61326-1; FCC Part 5 |
Vibration | 2G, IEC 68-2-6 |
Shock | 25G, IEC 68-2-29 |
Drop | Engineered to withstand 2 meter (6.5 feet) drop |
Size (H x W x L) | 28.4 cm x 8.6 cm x 13.5 cm (11.2 in x 3.4 in x 5.3 in) |
Weight (battery included) | 0.73 kg (1.6 lb) |
Enclosure rating | IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
For full Fluke Ti95 product specifications, please click here: Fluke Ti95