Fluke TiS60+ Plus Infrared Thermal Imager Camera
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA Only
- Fluke TiS60+ Plus Infrared Thermal Imager Camera (BC# -L/T*)
- AC Adapter/Charger
- Power Cord
- Carrying Case
Fluke TiS60+ Plus Infrared Thermal Imager Camera 30hz 320x240
Boost your team’s performance with 320 x 240 resolution. Infrared images taken with the TiS60+ capture smaller temperature differences from further away. If you are new to thermal imaging or if your camera is being used by a team with varying levels of thermal imaging experience, the TiS60+ offers easy-to-use fixed focus.
IR-Fusion technology, patented by the Fluke Corporation, automatically captures a digital visible light image at the same time as an infrared image. The camera blends the two images together, pixel for pixel, in a single display. You can then view the image in full infrared, full visible light or at several degrees of blending in between.
The location of an infrared target can be precisely identified even if the infrared contrast is low and there is very little structure in the infrared image.
See the problem and the location in one image with IR-Fusion technology
- 320 x 240 resolution for the clarity and image detail you need
- 3.5 inch LCD screen so you can recognize issues in the field
- Easy to use fixed focus, just point and shoot
- Measure up to 400 °C to handle all your applications
- One-handed image capture, review and save capability
Specifications:
| IFOV (spatial resolution) | 1.86 mRad, D:S 532:1 |
| Field of view | 34.1 °H x 25.6 °V |
| Minimum focus distance | 46 cm (18 in) |
| Ruggedized display | 3.5 inch (8.9 cm landscape) 320 x 240 LCD |
| Built-in digital camera (visible light) | 5MP |
| Temperature range (not calibrated below -10 °C) | -20 °C to 400 °C (-4 °F to 752 °F) |
| Accuracy | ± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
| On-screen emissivity correction | Yes (both value and table) |
| Infrared spectral band | 7.5 μm to 14 μm |
| Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
| Storage temperature | -20 °C to +50 °C (-4 °F to 122 °F) without batteries |
| Relative humidity | 10 % to 95 %, non-condensing |
| Safety standards | IEC 61010-1: Overvoltage category II, Pollution Degree 2 |
| Electromagnetic combability | IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A |
| Enclosure rating | IP54 (protected against dust, limited ingress; protection against water spray from all directions) |