Fluke TiX560 60Hz Infrared Thermal Imager
$8,049.00
Availability:
In stock
SKU
Ti80
Condition: Refurbished / Calibrated
Warranty: 1 Year Warranty
Shipping: USA Only
- Fluke TiX560 Infrared Thermal Imager (BC# -L/T*)
- USB PC Interface Cable
- AC Adapter/Charger
- Battery Pack
- User Manual On CD-ROM
- Carrying Case (G)
Request a Quote for
Fluke TiX560 Thermal Imager
Your view of infrared technology is about to change 180°
- Easily navigate over, under and around objects with the 180° articulating lens and see the image before you capture it
- Premium in-field viewing experience with the only 5.7 inch responsive touchscreen LCD in its class¹— 150 % more viewing area
- Enhanced image quality and temperature measurement accuracy – turn your 320 x 240 images into 640 x 480 images, that’s 4x’s the resolution and pixels with SuperResolution
- Get an in-focus image with the touch of a button. LaserSharp® Auto Focus, exclusive to Fluke, uses a built-in laser distance meter that calculates and displays the distance to your designated target with pinpoint accuracy
- See, save and share from the field and connect to the largest selection of wireless test and measurement tools with Fluke Connect
Features:
- SPATIAL RESOLUTION
- TiX560 1.31 mRad
- RESOLUTION
- 320 x 240 (76,800 pixels) and 640x480 (307,200 pixels) with SuperResolution Mode
- FILTER MODE (NETD IMPROVEMENT)
- ≤ 0.03 °C at 30 °C target temp (30 mK)
- TEMPERATURE RANGE
- -20 °C to +1200 °C (-4 °F to +2192 °F)
- IMAGE SHARPENING
- Image sharpening improves image clarity and quality
Specifications:
| IFOV with standard lens (spatial resolution) | 1.31 mRad |
| Detector resolution | 320 x 240 (76,800 pixels) |
| Field of view | 24 °H x 17 °V |
| Minimum focus distance | 15 cm (approx. 6 in) |
| IFOV with optional telephoto lens | 0.65 mRad |
| Field of view | 12 °H x 9 °V |
| Minimum focus distance | 45 cm (approx. 18 in) |
| IFOV with optional wide-angle lens | 2.62 mRad |
| Field of view | 46 °H x 34 °V |
| Minimum focus distance | 15 cm (approx. 6 in) |
| SuperResolution | On camera and in software |
| Image sharpening | Yes |
| LaserSharp® Auto Focus | Yes, for consistently in-focus images. Every. Single. Time. |
| Laser distance meter | Yes, calculates distance to the target for precisely focused images and displays distance on screen |
| Advanced manual focus | Yes |
| Streaming video (remote display) | Via USB or WiFi |
| Touchscreen display (capacitive) | 14.4 cm (5.7 in) diagonal landscape color VGA (640 x 480) LCD with backlight |
| Wireless connectivity | Yes |
| Wireless compatibility | Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi to LAN (where available) |
| Fluke Connect™ app compatible | Yes (where available) |
| Fluke Connect™ tool compatible | Yes (where available). Connects wireless to select Fluke Connect™ enabled tools. Five simultaneous connections supported |
| IR-Fusion® technology | Yes |
| AutoBlend™ mode | Yes |
| Picture-In-Picture (PIP) | Yes |
| Continuous AutoBlend™ | Set AutoBlend™ level across continuum |
| Rugged, ergonomic design | Rotatable (articulating lens) >180 degrees |
| Thermal sensitivity (NETD) | ≤ 0.045 °C at 30 °C target temp (45 mK) |
| Filter Mode (NETD improvement) | ≤ 0.03 °C at 30 °C target temp (30 mK) |
| Level and span | Smooth auto and manual scaling |
| Touchscreen adjustable level / span | Yes. Span and level can be easy and quickly set by simply touching the screen |
| Fast auto toggle between manual and auto modes | Yes |
| Fast auto-rescale in manual mode | Yes |
| Minimum span (in manual mode) | 2.0 °C (3.6 °F) |
| Minimum span (in auto mode) | 3.0 °C (5.4 °F) |
| Built-in digital camera (visible light) | 5 megapixel industrial performance |
| Frame rate | 60 Hz |
| Laser pointer | Yes |
| LED light (torch) | Yes |
| Digital Zoom | 2x, 4x, 8x |
| Data storage and image capture | |
| Extensive memory options | Removable micro SD memory card, on-board flash memory, save-to-USB capability, direct download via USB-to-PC connection |
| Image capture, review, save mechanism | One-handed image capture, review, and save capability |
| Post-capture Image Editing (on camera) | Yes. Conduct on camera analysis for in-field results |
| Advanced text Annotation | Yes. Including standard shortcuts as well as user programmable options |
| File formats | Non-radiometric (.bmp) or (.jpeg) or fully radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files |
| Memory review | Thumbnail view navigation and review selection |
| Software | SmartView® software, Fluke Connect™ (where available), and SmartView® Mobile App—full analysis and reporting software |
| Export file formats with SmartView® software | BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF |
| Voice annotation | 60 seconds maximum recording time per image; reviewable playback on camera; Bluetooth headset provided* |
| IR-PhotoNotes™ | Yes |
| Text annotation | Yes |
| File formats video | Standard and radiometric |
| Remote control and operation (for special and advanced applications) | Non-radiometric (MPEG - encoded .AVI) and fully radiometric (.IS3) |
| Auto capture (temperature and interval) | Yes |
| Battery | |
| Batteries (field-replaceable, rechargeable) | Two lithium ion smart battery packs with five-segment LED display to show charge level |
| Battery life | Three hours continuous use per battery pack |
| Battery charge time | 2.5 hours to full charge |
| Battery charging system | Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter |
| AC operation | AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) |
| Power saving | User selectable sleep and power off modes |
| Temperature measurement | |
| Temperature measurement range (not calibrated below -10 °C) | -20 °C to +1200 °C (-4 °F to +2192 °F) |
| Accuracy | ± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
| On-screen emissivity correction | Yes (both value and table) |
| On-screen reflected background temperature compensation | Yes |
| On-screen transmission correction | Yes |
| Color palettes | |
| Standard palettes | 8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
| Ultra Contrast™ palettes | 8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra |
| General specifications | |
| Color alarms (temperature alarms) | High-temperature and low-temperature |
| Infrared spectral band | 7.5 μm to 14 μm (long wave) |
| Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
| Storage temperature | -20 °C to +50 °C (-4 °F to 122 °F) without batteries |
| Relative humidity | 10 % to 95 % non-condensing |
| Center-point temperature measurement | Yes |
| Spot temperature | Hot and cold spot markers |
| User-definable spot markers | 3 user-definable spot markers |
| Center box | Expandable-contractible measurement box with MIN-MAX-AVG temp |
| Safety | IEC 61010-1: Overvoltage Category II, Pollution degree 2 |
| Electromagnetic compatibility | IEC 61326-1: Basic EM Environment CISPR11, Group 1, Class A |
| Australian RCM | IE 61326-1 |
| US FCC | CFR 47, Part 15 Subpart B |
| Vibration | 0.03 g2/Hz (3.8 grms), 2.5g IEC 68-2-6 |
| Shock | 25 g, IEC 68-2-29 |
| Drop | Engineered to withstand 1 meter (3.3 feet) drop with standard lens |
| Size (H x W x L) | 27.3 cm x 15.9 cm x 9.7 cm (10.8 in x 6.3 in x 3.8 in) |
| Weight (battery included) | 1.54 kg (3.4 lb) |
| Enclosure rating | IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
For full Fluke TiX560 Thermal Imager product specifications, please click here: Fluke TiX560