Fluke 5700ANV3 Series 2 Multifunction Calibrator

$18,999.00
Availability: In stock
SKU
1G24

Condition: Refurbished / Calibrated

Warranty: 1 Year Warranty

Shipping: USA & Worldwide

  • Fluke 5700ANV3 Series 2 Multifunction Calibrator (BC# -L/T*)
  • Power Cord
Request a Quote for

Have questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

We are commited to win your business!

Fluke 5700ANV3 Series 2 Multifunction Calibrator

The Fluke 5700ANV3 Series II is a high-precision multifunction calibrator used to verify and adjust electrical measuring instruments. Designed for calibration laboratories, service departments, and manufacturing facilities, it supplies stable electrical reference signals for checking digital multimeters and other precision meters. By comparing an instrument’s readings with these known outputs, technicians can determine its measurement accuracy.

The calibrator combines DC voltage, AC voltage, DC current, AC current, and resistance functions in one bench instrument. It provides DC voltage outputs up to ±1,100 volts, DC current outputs up to ±2.2 amps, and discrete resistance values up to 100 megohms. Its AC capabilities allow technicians to check instrument performance at different frequencies, with available output levels depending on the selected range and frequency.

During a typical calibration, a technician connects a meter to the Fluke calibrator and selects a reference value, such as 10 volts DC. The meter’s displayed reading is then compared with that reference to calculate its error. Repeating this process at multiple test points helps establish whether the meter meets its accuracy requirements and whether adjustments are necessary.

The 5700ANV3 Series II supports manual operation through its front-panel controls and automated operation through IEEE-488 and RS-232 interfaces. An optional wideband AC voltage function provides signals at frequencies up to 30 MHz. When paired with a compatible Fluke 5725A amplifier, the system can extend current output capability to 11 amps, expanding the range of instruments it can calibrate.

Features:

  • Multiple calibration functions: Supplies precision DC voltage, AC voltage, DC current, AC current, and resistance.
  • DC voltage output: Covers 0 to ±1,100 V.
  • AC voltage output: Reaches 1,100 V, with frequency coverage from 10 Hz to 1 MHz, depending on the output range.
  • DC current output: Covers 0 to ±2.2 A.
  • AC current output: Covers 9 µA to 2.2 A, with frequency coverage from 10 Hz to 10 kHz.
  • Precision resistance: Provides 18 discrete resistance values, plus zero, up to 100 MΩ.
  • Front-panel controls: Allows manual selection and adjustment of output values and frequencies.
  • Automated calibration support: Connects to computer-controlled systems through IEEE-488 and RS-232 interfaces.
  • Artifact Calibration: Uses a small set of external reference standards to calibrate its output functions.
  • Cal Check: Helps monitor changes in performance between calibrations.
  • Optional wideband output: Extends AC voltage frequency coverage to 30 MHz with the installed wideband option.
  • External amplifier support: Extends current output to 11 A when paired with a Fluke 5725A amplifier.
  • Rack-mount capability: Supports installation in laboratory and automated test racks using optional hardware.

 

Specification Fluke 5700ANV3 Series II
Manufacturer Fluke
Instrument type Precision multifunction calibrator
Output functions DC voltage, AC voltage, DC current, AC current, resistance
DC voltage range 0 to ±1,100 V
AC voltage maximum 1,100 V; frequency-dependent
AC voltage frequency coverage 10 Hz–1 MHz; range-dependent
DC current range 0 to ±2.2 A
AC current range 9 µA–2.2 A
AC current frequency coverage 10 Hz–10 kHz; range-dependent
Resistance coverage Zero and discrete values up to 100 MΩ
Optional wideband AC output 300 µV–3.5 V, 10 Hz–30 MHz
Optional amplified current Up to 11 A with external Fluke 5725A
Computer interfaces IEEE-488 and RS-232
Maximum warm-up time 30 minutes
Operating temperature 0°C–50°C
Calibration temperature 15°C–35°C
Storage temperature −40°C–75°C
Maximum operating altitude 2,000 m
Selectable supply voltage 100, 110, 115, 120, 200, 220, 230, or 240 VAC
Supply frequency 47–63 Hz
Maximum power consumption 300 VA
Dimensions, H × W × D 17.8 × 43.2 × 63.0 cm
Additional height for feet 1.5 cm
Weight Approximately 27 kg
Installation options Rack mounting and rear outputs