Hioki 3169 Clamp On HiTest Power Quality Analyzer
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- Hioki 3169-20 Clamp On Power HiTester (BC# 29373-L/T*)
- (4) Hioki 9661 Clamp-On Sensors
- (4) Hoioki Test Leads
- Hioki 32MB Flash Card w/ Adapter
- Power Cord
- User Manual On Cd-ROM
- Carrying Case (G)
Hioki Clamp On 3169-20 Power Tester
CLAMP ON POWER HiTESTERs are 3169-20 and 3169-21 that allow measurement of single-phase to three-phase 4-wire circuits with a single unit. In addition to measuring standard parameters such as voltage, current, power, power factor, and integrated values, these clamp-on power meters can simultaneously perform demand measurements required for carrying out power management and energy-saving measures, as well as harmonic measurements. The two new power meters also feature PC card data storage, and come equipped with an RS-232C interface for PC communications. Further, with greater data processing speeds, it is possible to measure the power of just a few cycles, enabling more detailed and effective energy-saving measures for equipment. The 3169-20 and 3169-21 are ideal for users who want to achieve close control over energy-saving management activities and measures.
Features:
- Measure power lines of up to four systems (with a common voltage)
- A wide range of measurement functions
- Equipped with ranges from 0.5 A to 5000 A
- Supports high-speed data storage from individual waveforms
- PC Card compatible plus internal hard drive for extra memory
- Housed in a compact A5 body size
- Multi-language Compatibility
- Detect incorrect connection using vector diagrams
- Polarity display and measurement using the reactive power measurement method
- High-speed D/A output
- Ideal for power and harmonics management
Range Configuration Table:
| CLAMP ON SENSOR 9661 (5A, 10A, 50A, 100A, 500A) |
Connection | 5.0000A | 10.000A | 50.000A | 100.00A | 500.00A |
150.00V |
Single-phase 2-wire | 750.00 W | 1.5000kW | 7.5000kW | 15.000kW | 75.000kW |
| Single-phase 3-wire | 1.5000kW |
3.0000kW |
15.000kW |
30.000kW |
150.00kW |
|
| Three-phase 3-wire | ||||||
| Three-phase 4-wire | 2.2500kW | 4.5000kW | 22.500kW | 45.000kW | 225.00kW | |
300.00V |
Single-phase 2-wire | 1.5000kW | 3.0000kW | 15.000kW | 30.000kW | 150.00kW |
| Single-phase 3-wire | 3.0000kW |
6.0000kW |
30.000kW |
60.000kW |
300.00kW |
|
| Three-phase 3-wire | ||||||
| Three-phase 4-wire | 4.5000kW | 9.0000kW | 45.000kW | 90.000kW | 450.00kW | |
600.00V |
Single-phase 2-wire | 3.0000kW | 6.0000kW | 30.000kW | 60.000kW | 300.00kW |
| Single-phase 3-wire | 6.0000kW |
12.000kW |
60.000kW |
120.00kW |
600.00kW |
|
| Three-phase 3-wire | ||||||
| Three-phase 4-wire | 9.0000kW | 18.000kW | 90.000kW | 180.00kW | 900.00kW |
| FLEXIBLE CLAMP ON SENSOR 9667 | Connection | 500.00 A | 5.0000kA |
150.00V |
Single-phase 2-wire | 75.000kW | 750.00kW |
| Single-phase 3-wire | 150.00kW |
1.5000MW |
|
| Three-phase 3-wire | |||
| Three-phase 4-wire | 225.00kW | 2.2500MW | |
300.00V |
Single-phase 2-wire | 150.00kW | 1.5000MW |
| Single-phase 3-wire | 300.00kW |
3.0000MW |
|
| Three-phase 3-wire | |||
| Three-phase 4-wire | 450.00kW | 4.5000MW | |
600.00V |
Single-phase 2-wire | 300.00kW | 3.0000MW |
| Single-phase 3-wire | 600.00kW |
6.0000MW |
|
| Three-phase 3-wire | |||
| Three-phase 4-wire | 900.00kW | 9.0000MW |
Specifications:
| Basic Specifications: | |
| Measurement line type | Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, and three-phase 4-wire systems (50/60 Hz) |
| Number of systems that can be measured (for systems that share the same voltage) | Single-phase: 1P2W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 systems 1P3W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 systems Three-phase: 3P3W2M (measures the voltage and current for two lines) . . . . . . 2 systems 3P3W3M (measures the voltage and current for all three lines) . . . 1 system 3P4W (measures the voltage and current for three lines) . . . . . . . . 1 system 3P4W4I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 system |
| Item | Voltage, current, active power, reactive power, apparent power, power factor, integrated value, frequency, harmonics |
| Measurement range | For the voltage, current, and active power ranges, see the range configuration tables |
| Measurement method | : Simultaneous digital sampling of voltage and current, PLL synchronization or a fixed clock (50/60 Hz) |
| Input methods | Voltage: Isolated input Current: Isolated input using a clamp-on sensor |
| Effective measurement area | Within 5 to 110% of the range |
| Total display area | Voltage and current: Within 0.4 to 130% of the range (zero is suppressed for less than 0.4%) Power: Within 0 to 130% of the range (zero is suppressed when the voltage or current is zero) Harmonic level: Within 0 to 130% of the range |
| Display | 5.7-inch LCD (320 × 240 dots), with backlight |
| Range switching method | Manual (the current range can be set for each system) |
| Display update rate | Approx. every 0.5 seconds (except when using a PC card while accessing the internal memory, or when performing RS-232C communications) |
| Input resistance (50/60 Hz) | Voltage: 2.0 M? ± 10% (differential input) Current: 200 k? ± 10% |
| Maximum input | Voltage input: 780 Vrms AC, peak value: 1103 V Current input: 1.7 Vrms AC, peak value: 2.4 V |
| Maximum rated voltage to earth | Voltage input terminals: 600 Vrms AC (50/60 Hz) |
| Crest factor | Voltage: Less than 2 (for full-scale input) Current: Less than 4 (for full-scale input. However, less than 2 for the 500 A, 1 kA, and 5 kA ranges) |
| Internal memory capacity | 1MB |
| Display Specifications | |
| Instantaneous value display | Voltage, current, active power, reactive power, apparent power, power factor, frequency, average voltage, average current, (average values are for each system) |
| Average value display | Voltage, current, active power, reactive power, apparent power, power factor, frequency, average voltage, average current |
| Maximum/minimum value display |
Voltage, current, active power, reactive power, apparent power, power factor, frequency |
| Integrate display | Integrated value Active power (consumption/regeneration) Reactive power (lag/lead) |
| Demand volume display (Integrated value within the specified interval) |
Integrated value Active power volume (consumption/regeneration) Reactive power volume (lag/lead) |
| Demand value display (average value within the specified interval) |
Active power (consumption), reactive power (lag), power factor |
| Maximum demand value display (average value within the maximum specified interval) |
The maximum demand value since the beginning of time series measurement and the time and date it occurred. |
| Harmonics list | List of the items measured for the specified harmonic (numerical value). |
| Harmonics graph | Bar graph or vector diagram of the items measured for the specified harmonic |
| Waveform display | Voltage and current waveforms (with a magnification update function) |
| Measurement value enlargement display |
Select and enlarge up to 5 items from the instantaneous value display. |
| Measurement Specifications | |
| Measurement method | True RMS method |
| Measurement display | Measurement of three voltage lines and 3 or 4 current lines is possible when using three-phase 3-wire and three-phase 4-wire systems |
| Measurement display | For three-phase 3-wire (the 3P3W3M setting), refer to the display for phase power values. |
| Polarity display | For consumption: no symbol, for regeneration: "-" |
| [Reactive power measurement] Using the reactive |
ON: Measures the reactive power directly using the reactive power measurement method OFF: Calculates the reactive power from the measurement values for voltage, current, and active power |
| Polarity display | For lag phase (LAG : current is slower than voltage): no symbol For lead phase (LEAD: current is faster than voltage) : "-" (Reactive power measurement method "ON") |
| [Apparent power measurement] Polarity display |
No polarity |
| [Power factor measurement] Measurement range |
1.0000 (lead) to 0.0000 to +1.0000 (lag) For lag phase (LAG: current is slower than voltage) :no symbol For lead phase (LEAD: current is faster than voltage) : "-" |
| Measurement range | 40.000 to 70.000 Hz |
| Input area for guaranteed accuracy | Within 10 to 110% of the range (for sine wave input) |
| Measurement source | Voltage U1 |
| Measurement range | 40.000 to 70.000 Hz |
| Input area for guaranteed accuracy | Within 10 to 110% of the range (for sine wave input) |
| Measurement source | Voltage U1 |
| [Integrated measurement] Measurement range |
Active power : 0.00000 mWh to 99999.9 GWh consumption -0.00000 mWh to -99999.9 GWh regeneration Reactive power : 0.00000 mvarh to 99999.9 Gvarh lag -0.00000 mvarh to -99999.9 Gvarh lead |
| Measurement display | Active power : Displays consumption and regeneration separately Reactive power : Displays lag and lead separately |
| [Harmonic measurement] Measurement range |
Basic wave frequency: 45 to 66 Hz PLL synchronization |
| Order for analysis | Up to the 40th order |
| Window width | A single cycle (number of data points analyzed: 128 points) |
| Window type | Rectangular |
| Analysis rate | 1/16 cycles |
| Item for analysis | Harmonic level: The voltage, current, or power level for each harmonic order : Harmonic content percentage: The voltage, current, or power content percentage for each harmonic order : Harmonic phase angle: The voltage, current, or power phase angle for each harmonic order : Total value: The total value for voltage, current, or power up to the 40th harmo |
| Setting Specifications | |
| Measurement line settings | 1P2W, 1P3W, 3P3W2M, 3P3W3M, 3P4W, 3P4W4I |
| Clamp-on sensor settings | 9694, 9660, 9661, 9667, 9669, 9695-02 and 9695-03 (* A different sensor can be set for each system.) |
| VT (PT) and CT ratio settings | 0.01 to 9999.99 (* A different CT ratio can be set for each system.) |
| Measurement start method | Manual or time (year, month, day, hour, minute) |
| Measurement stop method | Manual, time, or timer (1 seconds to 8784 hours) |
| Output Interval | Standard or fast (*Maximum measurement period: 1 year) Standard interval: 1, 2, 5, 10, 15, or 30 seconds, or 1, 2, 5, 10, 15, 30, or 60 minutes Fast interval: A single waveform, or 0.1, 0.2, or 0.5 seconds |
| Data output destination | PC card, internal memory, or printer |
| File name | Automatically attached, or set the desired name (up to 8 alphanumeric characters) |
| Display averaging circuit | OFF, 2, 5, 10, 20 times (for movement averaging) |
| Screen copy destination | PC card, internal memory, or printer |
| Display language settings | Japanese, English, German, French, Italian, Chinese (Simple, Trad), Spanish , Korean |
| Other settings | Reactive power measurement method selection, harmonic distortion selection, order display selection, backlight settings, ID settings, clock settings, etc. |
| Copy file | Copies files from the internal memory to the PC card |
| Load/Save selected file | Loads/Saves the file(s) selected from the internal memory or PC card |
| Delete file | Deletes the file(s) from the PC card |
| Format | Initializes the PC card or internal memory. |
| Storage format | Measurement data: CSV format (binary format when using the fast interval setting) Waveform data: Binary format Screen data: BMP format Settings data: CSV format |
| Instantaneous values | Voltage, current, active power, reactive power, apparent power, power factor, frequency, average voltage, average current, (average values are for each system) |
| Average value | Voltage, current, active power, reactive power, apparent power, power factor, frequency, average voltage, average current, (average values are for each system) |
| Maximum/minimum value | Voltage, current, active power, reactive power, apparent power, power factor, frequency |
| Integrated value | Active power (consumption/regeneration) Reactive power (lag/lead) |
| Demand value | Active power (consumption), reactive power (lag), power factor |
| Maximum demand value | The maximum demand value since the beginning of time series measurement and the time and date it occurred. |
| Harmonic | : Each harmonic order (level, content percentage, and phase angle), total value, instantaneous value for THD-F/THD-R : Each harmonic order (level, content percentage, and phase angle), total value, average value for THD-F/THD-R for each interval : Each harmonic order (level, content percentage, and phase angle), total value, maximum/minimum value for THD-F/THD-R within each interval |
| Waveform | Waveform (Voltage or current) |
| Status information | Exceeds the voltage/current crest factor, PLL unlock, power failure, exceeds the display limit |
| Numerical values | Prints the data selected as the data output item (during time series measurement). |
| Waveform | Hard copy of the screen (printing of each interval not available) |
| General Specifications | |
| Operating environment | Indoors, up to 2000m(78.74ft) ASL |
| Operating temperature and humidity | 0 to 40°C, 80% RH or less (non-condensating) |
| Storage temperature and humidity | -10 to 50°C, 80% RH or less (non-condensating) |
| Withstand voltage (50/60 Hz for 15 sec.) | 5.55 kVrms AC: Between the voltage input terminal and the 3169 casing 3.32 kVrms AC: Between the voltage input terminal and the current input terminal/external interface terminal 2.3 kVrms AC: Between the power supply and the 3169 casing 1.39 kVrms AC: Between the power supply and the current input terminal/external interface terminal |
| Power supply voltage rating | 100 to 240 V AC, 50/60 Hz |
| Maximum rated power | 30 VA |
| Dimensions and weight | Approx.210(8.27?)W × 160(6.30?) H × 60D(2.36?) mm (excluding protrusions), Approx.1.2 kg(42.3oz.) (3169-20, 3169-21) |
| Conforming standards | Safety EN61010 Pollution degree 2, measurement category ? (anticipated transient overvoltage 6000V) : EMC EN61326 EN61000 - 3 - 2, EN61000 - 3 - 3 |
For full Hioki 3169 product specifications, please click here: Hioki 3169
Sell Your Equipment
At AAATesters we are committed to helping you maximize the value of your surplus, excess and underutilized Test Equipment. We buy Test Equipment of all makes and models.
If you would like to Sell your Equipment, please submit the Request form below.
Reasons to Sell to Us
• Quick & Easy Process to Sell or Trade Equipment
• Get Cash Today! or Trade-in Credit for New or Refurbished Equipment
• Free Shipping - We will Pay for Shipping to us. We can even setup, pack and pickup the Equipment you are selling to us
• Improve ROI, Operational Efficiency, Budget Management, and Planning of your Future Needs