Fluke Networks OFTM-5612 MM Fiber Optic OTDR Module

Fluke Networks OFTM-5612 MM Fiber Optic OTDR Module

JDSU COSA-4055 CWDM Spectrum Analyzer Module For T-BERD 2000 COSA4055

JDSU COSA-4055 CWDM Spectrum Analyzer Module For T-BERD 2000 COSA4055

JDSU T-BERD 4126 MP SM Long Haul Fiber OTDR Module 43dB

$1,995.00
Availability: Out of stock
SKU
3L115

Condition: Refurbished / Calibrated

Warranty: 1 Year Warranty

Shipping: USA & Worldwide

Request a Quote for

Have questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

We are commited to win your business!

  • JDSU T-BERD 4126 MP SM Long Haul Fiber OTDR Module (BC# 7445B-L/T*)
    • SM OTDR Source:
      • 1310nm
      • 1550nm

JDSU 4126MP SM Fiber OTDR Module
The JDSU MP OTDR module provides the optimum performance that fiber installers and service providers need to test metro, cable TV (CATV) and FTTH networks with high-port-count splitters.

 

With various wavelength combinations including filtered wavelengths for in-service testing, an improved dynamic range, and optimized resolution and dead zones at short pulses, the MP module is the ideal OTDR to test any PON system with up to a 1x128 splitting ratio. The MP module's optical performance, combined with the T-BERD/MTS platform's complete suite of features, ensures that testing is done right the first time.

 

Features:

  • Up to 43 dB dynamic range and 256,000 acquisition points
  • PON-optimized to test up to a 1x128 splitter
  • Single connector port for 1310, 1550, and inservice 1625 nm or 1650 nm wavelengths
  • Integrated CW light source and power meter
  • FiberComplete™ compatible
  •  Ready for SLM, FTTA-SLM, and FTTH-SLM intelligent optical application software
  • Instantly detects traffic when connected to live fiber

 

Specifications:

General (typical at 25°C)
Weight 0.35 kg (0.77 lb)
Dimensions 128 x 134 x 40 mm (5 x 5.28 x 1.58 in)
Optical Interfaces
Interchangeable optical connectors FC, SC, DIN, LC and ST
Technical
Laser safety class (21 CFR) Class 1
Distance units Kilometers, feet, and miles
Group index range 1.30000 to 1.70000 in 0.00001 steps
Number of data points Up to 256,000 data points
Distance measurement Automatic or dual cursor
Display range 0.5 to 260 km
Cursor resolution 1 cm
Sampling resolution 4 cm
Accuracy ±1 m ±sampling resolution ±1.10−5 x distance (excluding group index uncertainties)
Attenuation measurement
Automatic, manual, 2-point, 5-point and LSA
Display range 1.25 dB to 55 dB
Display resolution 0.001 dB
Cursor resolution 0.001 dB
Linearity ±0.03 dB/dB
Threshold 0.01 to 5.99 dB in 0.01 dB steps
Reflectance / ORL Measurements
Reflectance accuracy ±2 dB
Display resolution 0.01 dB
Threshold −11 to −99 dB in 1 dB steps
CW Source
CW Source output power level −3.5 dBm
MP OTDR
Central wavelength 1310 ±20 nm
1550 ±20 nm
Pulse width 3 ns to 20 µs
RMS dynamic range 43dB
41dB
Event dead zone 80 cm
Attenuation dead zone 4 m