JDSU Certifier 40G NGC-4500-CuQEFMPO Cable Certifier Kit
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- JDSU Certifier 40G Main Unit (BC# 6583A-L/T*)
- JDSU Certifier 40G Remote Unit (BC# 6583B-L/T*)
- (2) JDSU MM Fiber Modules
- 850nm
- 1300nm
- (2) JDSU SM Fiber Modules
- 1310nm
- 1550nm
- (2) JDSU Cat6A Link Adapters
- (2) JDSU Cat6A Channel Adapters
- JDSU MPO/MTP Light Source
- JDSU MPO/MTP Power Meter
- (2) RJ45 To TERA Cables
- (2) SM SC-SC Fiber Cables
- (2) MM SC-SC Fiber Cables
- (2) Stylus'
- (2) Headset / Talksets
- (2) Protective Screen Covers
- (2) Straps For Units
- (2) AC Adapter/Chargers
- (2) Power Cords
- User Manual On CD-ROM
- Carrying Case w/ Strap
JDSU Certifier 40G
The industry standard in enterprise certification
Data consumption has exploded in the past few years and enterprise network owners are scrambling to meet the demanding requirements of 40 G and beyond to serve their buildings, data centers, and campuses. New technologies are driving change in every aspect of enterprise networks—new industry standards, new topologies, new types of connectivity, new test methods, and certainly new challenges for designers and technicians. Everything in the enterprise is new!
Our customers tell us that their old tools are insufficient for new enterprise networks. The Viavi Solutions Certifier40G equips technicians with all the capabilities they need to certify both copper and fiber networks quickly, completely, and correctly for all current and future cabling standards for the new enterprise.
Drive User Efficiency
The Certifier40G is not only the most advanced solution available, it is also the fastest and most complete. Whether certifying copper or fiber, users will get the job done right and on time…the first time!
- The industry’s fastest CAT6A solution can certify each cable within 9 seconds, saving users 30 minutes each time they test 150 CAT6A cables
- Tier 1 certification of multimode, single-mode, and multimode MPO fiber in less than 6 seconds
- Automate pass/fail end-face analysis for all fiber types
- Gain complete test visibility at both local and remote ends
- Pre-configured with all leading manufacturer’s cabling specifications
Copper cabling systems are rapidly evolving to support the new enterprise. With the IEEE working to ratify 802.3bq (40GBASE-T), and TIA moving quickly to ratify Category 8 cabling systems, the need to test cabling systems to beyond 2000 MHz is on the horizon. The Viavi Certifier40G is the only certification tool on the market today that is ready for these new standards. The Viavi Certifier40G has been ETL verified to ANSI/TIA-1152 Level IIIe, IEC 61935-1 Levels IIIe and IV, and Level V draft accuracy specifications.
The current IEC 61935-1 proposed Level V draft accuracy standard addressed the needs up to Class FA (1000 MHz). The Viavi Certifier40G is accurate beyond 2000 MHz and, therefore, will support the latest standards being developed to protect your investment.
Easily Test 10/40/100 G MPO Links
In new enterprise architectures, the use of parallel optics has become essential to achieve the demand for high-speed 40 G and 100 G transmission. From active media incorporating quadrature small form-factor pluggable (QSFP) transceivers to using trunk cables and cassettes, MPO connectivity is essential for delivering speeds of 40 G and beyond in the enterprise.
- The industry’s only modular certifier with MPO test capability
- Test MPO to LC/SC
- Conduct 5-second loss and polarity tests on 12 fibers
- Discover or ensure correct polarity with Fiber Map
- Display absolute and relative power levels
- Measure MPO power on live systems
Dirty connectors are the number one cause for troubleshooting in optical networks. Microscopic dirt particles create enough signal loss and back reflection to cause significant network errors and downtime. Proactively inspecting fiber end faces is critical for testing and certifying a fiber network. The Telecommunications Industry Association (TIA) recently revised TIA-568 to establish quality and cleanliness acceptance criteria for fiber connector end faces when testing optical connections. Whether using TIA-568 or customerspecific requirements, users can easily inspect and certify fiber connector end faces with automated pass/fail analysis at the push of a button on the Certifier40G to get the job done quickly and correctly.
- Prove compliance to the new TIA-568 end-face inspection requirements
- Get fast results at the push of a button
- Eliminate subjectivity with automated pass/fail analysis
- Ensure your network is optimized for a lifetime of performance
- Prevent costly network downtime and time-consuming troubleshooting
Voice and video, cloud computing, and virtualization are driving an increasing demand for fiber-cabling networks. To guarantee that these new fiber networks can handle higher data rates, they must be certified based on the TIA-568 and ISO 11801 industry standards, which specify the insertion loss and length requirements for each type of fiber-optic cabling. The Viavi Certifier40G fiber test adapters quickly and accurately certify any fiber-cabling installation. These adapters complement an existing, comprehensive copper-cabling feature set, letting structured-cabling installers and professionals perform all their fiber and copper certifications with the same, easyto-use tool.
- Perform standards-compliant loss measurements of multimode fiber cabling with encircled flux (EF) multimode test heads; EF launch conditions are required by TIA and IEC standards and help ensure consistency and accuracy of loss results
- Two complete user interface touch screens show full fiber results at both ends giving technicians complete results for all fibers and all wavelengths—not just a pass/fail light
Comprehensive, Easy-to-Use Reporting
Manage your test results and generate professional reports for all your test results with J-Reporter, the Viavi reporting platform for the Certifier40G. Included with the Certifier40G, J-Reporter is PCbased software that produces consolidated reports for copper, fiber (including MPO and end-face certification with the Viavi P5000i optical scope), and OTDR traces from the Viavi T-BERD®/MTS-2000 instrument.
Additional features include:
- Adding a company’s logo and name
- Reporting in summary or detail
- Creating hierarchies for record keeping
To test and certify copper up to Category 6A, the Certifier10G is the cost-effective solution. Without support for fiber or Class FA, the Certifier10G is an entry-level copper certifier with the same benefits as Certifier40G. Contact Viavi for more information.
Key Benefits
- Achieve complete network certification with one device
- Optimize productivity with the industry’s fastest test workflow
- Obtain comprehensive results for the latest TIA-568 and ISO 11801 requirements
- View test set up and results data and edit labels at both local and remote ends
- Permanent link and channel adapters for certifying to TIA category 5e/6/6A and ISO class D/E/EA/F/FA
- Multimode (850/1300 nm) and singlemode (1310/1550 nm) adapters for Tier 1 fiber certification (loss/length/polarity)
- Multimode (850 nm) MPO adapters for certifying and troubleshooting MPO links and trunks
- Industry-leading JDSU P5000i digital fiber end-face inspection probe support
- Integrated, standards-based certification labeling and reporting
- Complete TIA 568/ISO 11801 copper and fiber certification
- TIA-942-A data center certification
- Certify plug-and-play (trunk/cassette) fiber connectors with MPO connectors.
- Objective pass/fail testing for IEC 61300-3- 35 fiber end-face requirements
Specifications:
Test Parameters | |
Frequency range | 1 to 2000 MHz |
TIA-1152 Level IIIe and ISO/IEC 61935-1 Level-IV accuracy | |
Copper Cable Tests | |
Attenuation (insertion loss) | |
Near-end crosstalk (NEXT) in pair-to-pair and power-sum | |
Attenuation-to-crosstalk ratio far end (ACRF), pair-to-pair, and power-sum | |
Return loss | |
Loop resistance | |
Wiremap and shield | |
Cable length | |
Total propagation delay | |
Delay skew between pairs | |
Fiber Cable Tests | |
Loss (in each direction) | |
Fiber cable length | |
Polarity | |
Test Standards | |
TIA -568-C.2 and TIA-1152 CAT-5, 5e, 6, 6A | |
ISO/IEC 11801, EN 50173 Class-C, D, E, EA, F, FA | |
TIA-568-C.3 Tier I Fiber certification | |
ISO/IEC 11801 Tier I Fiber certification | |
Power Supply | |
Removable/rechargeable lithium ion batteries provide up to 8 hours continuous operation | |
AC power adapter | 100−240 V AC |
Dimensions | |
Mainframe size | 232 x 126 x 86.7 mm (9.13 x 4.9 x 3.41 in) |
Mainframe height approx. (per unit) | 1.4 kg (3.0 lb) |
Module size | 84 x 70 x 27 mm (3.3 x 2.8 x 1.1 in) |
Memory | |
More than 500 MB (more than 2000 test results) of internal flash memory | |
1 GB USB flash drive included for flexible test record storage | |
Connectivity | |
Probe interface connector | |
RJ45 Ethernet port | |
USB host and device interfaces | |
Talk set interface: 3.5 mm stereo jack | |
Environmental | |
Operating temperature | 0 to 40°C |
Storage temperature | −20 to 60°C |
Relative humidity | 10 to 80% |
Pass/Fail Test Times | |
TIA CAT-6/CAT-6A test times | 9 s |
ISO Class -F/FA test times | 15 s |
TIA/ISO Tier I Fiber test time | 8 s |
For full JDSU Certifier 40G product specifications, please click here: JDSU Certifier 40G