  • JDSU T-BERD 2000 Modular Mainframe w/ Options: (BC# 7445A-L/T*)
    • SmartLink
    • Power Meter:
      • 850nm
      • 1300nm
      • 1310nm
      • 1490nm
      • 1550nm
      • 1625nm
      • 1650nm
  • JDSU T-BERD 4126 MP SM Long Haul Fiber OTDR Module (BC# 7445A-L/T*)
    • SM OTDR Source:
      • 1310nm
      • 1550nm
    • SC Connector For Source
  • Ethernet Cable
  • T-BERD 2000 Quick Reference Guide
  • Stylus
  • AC Adapter/Charger
  • USB PC Interface Cable
  • Carrying Case
Request a Quote for

Have questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

We are commited to win your business!

JDSU T-BERD 2000 Modular Test Set
Costs, workflow, quality, network performance, and customer experience are critical for the success of today’s fiber optic networks. Selecting the right test tools has become key toward meeting these needs.

The JDSU T-BERD 2000 is a handheld multi-test platform that provides field technicians with a single handheld unit to install, turn-up and maintain these networks to the highest standards.

Its innovative design ensures that all essential fiber test tools are close at hand, whatever the job or location. A large color screen with graphical user interface drives simple operation and optimal workflow in the field.

Test capabilities include a range of OTDR modules for multimode and single-mode testing, as well as a range of FiberCompleteTM modules for automated Insertion Loss/Optical Return Loss (IL/ORL), and fault finding. Both OTDR and FiberComplete modules are passive optical network (PON) optimized. The unit is also ready for conector end face pass/fail analysis to IEC standards with a digital analysis microscope.

Widest Range of Applications for Maximum Flexibility
The T-BERD 2000 provides the largest range of test capabilities offered in one handheld unit. The modular design allows service providers the maximum flexibility to scale their investment and evolve with the growth of their network.
The instrument supports the whole range of essential fiber analysis tools including connection inspection, connection check, source, ORL, OTDR, a power meter, a PON selective power meter, and CWDM optical spectrum analyzer.

Application modules used with the T-BERD 2000 can also be used with the T-BERD 4000 and the two products are interoperable.

Boosted Productivity with Seamless Data Workflow
The T-BERD 2000 integrates various communication capabilities allowing remote control, data and setup uploads/downloads, and report transfer. The unit has one high-speed 1G Ethernet port and three USB ports.

Features:

  • Large 5-inch touch-screen display
  • Field-installable modules
  • Wide range of OTDR modules including Quad and PON
  • FiberComplete automated IL/ORL, PON power meter, and CWDM analyzer
  • Automated fiber inspection and IEC pass/fail analysis
  • New-generation lithium polymer (LiPo) battery for 8-hour operation
  • Cross-compatible with T-BERD 4000


Specifications:

General (typical at 25°C)
Display
5-inch TFT color touch screen (12.5 cm)
 Resolution 800 x 480 WVGA
Interfaces
Two USB 2.0 ports
 One mini-USB 2.0 port
 RJ-45 LAN 10/100/1000 Mbps
Internal memory
1 GB (128 MB for storage)
Battery Rechargeable lithium-polymer battery
 8-hour operation as per Telcordia GR-196-CORE
Power supply AC/DC adapter, input 100-250 VAC,
 50-60 Hz; 2.5A max, output 12 VDC, 25W
Electrical safety: EN60950-compliant
Size with module (H x W x D)
175 x 138 x 80mm
 (6.9 x 5.4 x 3.2 in)
Weight
with battery
with battery and LM OTDR

0.864 kg (1.89 lbs)
1.21 kg (2.67 lbs)
Temperature Operating: -20 to +50°C (-4 to 122°F)
 Storage: -20 to +60°C (-4 to 140°F)
Relative humidity 0% to 95% non-condensing
Built-In Power Meter Specifications
Calibrated wavelengths
850/1310/1490/1550/ 1625/1650
Wavelength range 800 to 1650 nm in 1 nm steps
Accuracy ±0.2 dB
Measurement range +5 to −50 dBm
Maximum resolution 0.01 dB/0.01nW
Connector type Universal push pull (UPP)





JDSU 4126MP SM Fiber OTDR Module

The JDSU MP OTDR module provides the optimum performance that fiber installers and service providers need to test metro, cable TV (CATV) and FTTH networks with high-port-count splitters.

 

With various wavelength combinations including filtered wavelengths for in-service testing, an improved dynamic range, and optimized resolution and dead zones at short pulses, the MP module is the ideal OTDR to test any PON system with up to a 1x128 splitting ratio. The MP module's optical performance, combined with the T-BERD/MTS platform's complete suite of features, ensures that testing is done right the first time.

 

Features:

  • Up to 43 dB dynamic range and 256,000 acquisition points
  • PON-optimized to test up to a 1x128 splitter
  • Single connector port for 1310, 1550, and inservice 1625 nm or 1650 nm wavelengths
  • Integrated CW light source and power meter
  • FiberComplete™ compatible
  •  Ready for SLM, FTTA-SLM, and FTTH-SLM intelligent optical application software
  • Instantly detects traffic when connected to live fiber

 

Specifications:

General (typical at 25°C)
Weight 0.35 kg (0.77 lb)
Dimensions 128 x 134 x 40 mm (5 x 5.28 x 1.58 in)
Optical Interfaces
Interchangeable optical connectors FC, SC, DIN, LC and ST
Technical
Laser safety class (21 CFR) Class 1
Distance units Kilometers, feet, and miles
Group index range 1.30000 to 1.70000 in 0.00001 steps
Number of data points Up to 256,000 data points
Distance measurement Automatic or dual cursor
Display range 0.5 to 260 km
Cursor resolution 1 cm
Sampling resolution 4 cm
Accuracy ±1 m ±sampling resolution ±1.10−5 x distance (excluding group index uncertainties)
Attenuation measurement
Automatic, manual, 2-point, 5-point and LSA
Display range 1.25 dB to 55 dB
Display resolution 0.001 dB
Cursor resolution 0.001 dB
Linearity ±0.03 dB/dB
Threshold 0.01 to 5.99 dB in 0.01 dB steps
Reflectance / ORL Measurements
Reflectance accuracy ±2 dB
Display resolution 0.01 dB
Threshold −11 to −99 dB in 1 dB steps
CW Source
CW Source output power level −3.5 dBm
MP OTDR
Central wavelength 1310 ±20 nm
1550 ±20 nm
Pulse width 3 ns to 20 µs
RMS dynamic range 43dB
41dB
Event dead zone 80 cm
Attenuation dead zone 4 m