Fluke 80i-110s side

Fluke 80i-110s AC/DC Clamp-On Current Probe

JDSU UltraFED IIB 30 MHz Ultra Far End Device

$495.00
Availability: In stock
SKU
1L143

Condition: Refurbished

Warranty: 1 YEAR WARRANTY

 JDSU UltraFED IIB 30 MHz Far-End Device

Various DSL access technologies, such as VDSL2 bonding and vectoring, exploit existing copper and hybrid fiber-copper infrastructures letting service providers deliver higher-bandwidth IP video and multimedia content to their customers. Yet delivering the high quality of service (QoS) that customers expect requires accuracy that surpasses single-ended copper-loop testing limitations. Accurately testing for wideband services requires changing far-end line conditions based on the tests performed, which can be both time-consuming and costly. Few technicians possess the field expertise needed and declining training budgets only further exacerbate the copper testing problem.

The JDSU UltraFED IIB Far-End Device paired with the JDSU HST-3000 fills this critical testing need because it is like having an モexpert-in-a-boxヤ. The UltraFED IIB connects to the far end of the pair under test while the HST-3000 controls it remotely. One technician with one piece of equipment can now perform two-ended pair testing. Additionally, the UltraFED IIB can measure true near-end (NEXT) and far-end crosstalk (FEXT) for bonded VDSL and ADSL by terminating a second pair. For ultimate flexibility, the UltraFED IIB operates in two modes: passive mode where the HST-3000 activates the UltraFED IIB remotely for dual-ended testing and through mode where it automatically activates as needed to reduce downtime when troubleshooting marginal failures.

Isolating certain types of copper faults such as service-impacting bridged taps, splice failures, or cable sheath damage can be particularly troublesome, The OneCheckル Copper Test Suite option for the HST-3000 simplifies this process and reduces fault repair times through seven diagnostics that run to an UltraFED IIB at the far end.

Copper Testing is More Important than Ever
Dual-Ended Testing is Better ナ and Smarter
New VDSL2 technologies such as DSL bonding and vectoring are enabling higher bandwidths for service providers to deliver multimedia content to end users. However, to deliver the performance advantages that the new technologies offer, copper-loop testing and maintenance are more important than ever before.

In the past, single-ended copper-loop testing was often perceived as just as reliable and faster than dual-ended testing. In reality, technicians who test only from one end often misdiagnose faults on higher-bandwidth circuits, such as VDSL2. Technicians conducting dual-ended tests using an HST-3000 to remotely command the UltraFED IIB at the far end can isolate customer-affecting fault conditions that otherwise go undetected during turn-up and installation or during routine copper troubleshooting.

During Installation and troubleshooting, technicians who test to an UltraFED IIB over the loop reduce drive-time and, ultimately, repeat dispatches. This testing method provides accurate terminations and remote test capabilities, including strap (short), open, drop battery, and tones, letting technicians quickly isolate faults and identify noise.

Bonded Pair Turn-up and Fault Isolation
DSL-bonding technologies, according to ITU-T G.998.1, G.998.2, and G.998.3, leverage the existing technology by logically combining signals from two wire pairs to effectively double the downstream and upstream bit rates delivered to the user. However, several factors such as pair quality, frequency, and distance can affect the actual delivery rates. Optimal bandwidth delivery requires accurately testing bonded pairs. However, qualifying individual copper pairs at the physical layer fails to reveal a potentially adverse interaction, called crosstalk, between the bonded pairs when both are carrying xDSL service. The effects of crosstalk remain undetected until bringing up bonded service between the modem and DSLAM. The ability to assess crosstalk between two candidate pairs prior to provisioning can save significant time, minimize pair swapping efforts, and lower repeat rates.

Using the UltraFED IIB with a companion HST-3000 lets technicians measure both FEXT and NEXT from a single end by generating a tone on one pair while simultaneously terminating the second pair. The HST-3000 detects coupling at the near end (for NEXT) or from the far end (for FEXT) from one pair of wires to another and measures noise on another pair of wires at the near end.

Multiple Measurements are Better than Just One
When testing copper pairs, making pass or fail decisions from one test result alone, such as attenuation, stress, or TDR, can lead to erroneous or incomplete conclusions. The resistive, capacitive, and inductive characteristics of each conductor in the pair as well as the similarity of one conductor to the other (pair balance) can affect DSL performance. When troubleshooting or qualifying copper pairs, experienced technicians know that achieving the most accurate and trustworthy results in determining a pairメs health requires comparing  multiple measurements.

OneCheck Copper Test Suite offers a set of applications that can help technicians isolate faults up to three times faster than running separate tests. Each automated test in the OneCheck Copper Test Suite runs on an HST-3000 paired with a companion UltraFED IIB to assess either overall pair quality or to isolate specific fault types.

OneCheck Copper Test Suite
OneCheck Test Tests Runs Test Objective
OneCheck Copper for DSL  Foreign voltage (AC)
Foreign voltage (DC)
Resistance
Longitudinal balance
Series fault
Opens
Load coil
Bridged tap
Loop resistance
Wideband noise (per band)
Wideband impulse noise
Wideband SNR
Wideband balance
Wideband NEXT/FEXT
Power influence
Circuit noise
Wideband loss
Determines overall pair(s) health over the DSL technology
provided and includes thresholds and filters set by technology.
Lets users save results after test.
Helps to identify shorts, grounds, opens one-sided opens,
cable length, battery crosses, balance, splice failures, load
coils, bridged taps/laterals, crosstalk, power influence,
impulse-noise events, and excessive insertion loss.
OneCheck Series Fault Longitudinal balance (to open)
Longitudinal balance (to short)
Tip resistance
Ring resistance
Checks for series fault presence, typically from splice failures
where one conductor has greater resistance (in series) than
the other conductor.
Helps to identify bad splices and series-resistance faults
OneCheck Bridged Tap TDR
Opens (capacitance)
Determines bridged tap (lateral) existence on the pair, the
distance to it, as well as its length
OneCheck TrueLength Opens
Distance to short
TDR to open
TDR to short
Provides actual pair length by correlating capacitive and
resistive and TDR loop measurements along with a confidence
percentage.
OneCheck RFL Pretest Circuit resistance
Loop resistance
Indicates whether a resistive fault was found and identifies
which test to run next, RFL or K-Test, or to isolate the fault.
OneCheck Kick Test Foreign voltage (AC)
Foreign voltage (DC)
Circuit resistance
Opens
Capacitive Balance
Longitudinal balance
Quick copper-check test to assess the pairメs health before
final test.
UltraFED IIB is not required for this test.
OneCheck Shield Test RFL Determines resistance from the HST-3000 to the UltraFED IIB.


Like Having a モCopper Expert in a Boxヤ
HST-3000 TDR Helper Reduces Fault-Isolation Time

Identifying the end of copper pairs can be challenging even for expert technicians. To simplify fault location, the HST-3000 offers a unique feature that users can enable in the HST-3000 TDR menu called モTDR Helperヤ. TDR Helper sends DTMF tones to a remote UltraFED IIB to alternately open and short the line across tip/ring (or A/B) helping technicians identify the end of the cable pair by simply observing the dip up (open)/dip down (shorted) status. TDR Helper uniquely saves time and simplifies tip/ring (A/B) fault-finding when identifying load coils, wet sections, splices, and bridged taps.

Everything Field Technicians Need to Install and Repair Copper
Technicians can remotely control the UltraFED IIB with the HST-3000 to test all DSL service varieties, including single- and bonded-pair VDSL2/ADSL2+ as well as legacy HDSL. Technicians can use the HST-3000 Manual FED commands to set the test mode, tone frequency and duration, terminate the line with the correct impedance, and send a モwake-upヤ tone to UltraFED IIB before running the test. Or they can simply run a OneCheck automated test to automatically configure the test according to the technology being tested. The HST-3000 can isolate pairs, drop the telco/exchange battery, provide the strap for resistive fault location tests, send tone/ trace tone to the UltraFED IIB for the appropriate line condition, termination, and filters at the far end to achieve the most highly accurate test results.

UltraFED IIB Test Mode Functions
UltraFED IIB Test Mode Test Mode Function
Single Tone Connects a tone generator across tip (A) to ring (B) to measure loss
Trace Tone 1 Connects a tone generator across tip (A) to ring (B) and sends 577 and 1004 Hz tones at cadence 1
Trace Tone 2 Connects a tone generator across tip (A) to ring (B) and sends 577 and 1004 Hz tones at cadence 2
Balance Single Tone Connects a tone from tip (A) to ring (B) to ground to assess line balance in the xDSL frequency range
Quiet Termination Terminates the pair at the FED
Open All Disconnects tip (A), ring (B), and ground (sleeve) from the cable pairs to isolate the pair under test
Tip-Ring Short Also called strap mode. Connects tip (A) to ring (B) and is used with loop resistance or RFL measurements
Tip-Ring-Gnd Short Connects tip (A), ring (B), and ground (sleeve) to ground and is used while measuring resistive balance
RFL 3-Way Strap Connects tip (A) to T1 to ring (B) and is used primarily for measuring RFL on a verified good pair
TDR Helper Continuously opens and shorts the pair to identify the pairメs end
Off/Thru Connects tip (A) and ring (B) to the CO tip (A) and ring (B) to maintain モin-serviceヤ customer connection and モout-of-serviceヤ as necessary during test

UltraFED IIB ヨ Offers Best Way to Help Techs Work Like Experts
An UltraFED IIB simplifies two-ended testing with a single technician. The UltraFED IIB connects to the far end of the pair under test while the HST-3000 controls it remotely via DTMF tones. One piece of equipment can now perform two-ended pair testing, which is critical for accurately qualifying or repairing copper pairs for VDSL2 and bonded VDSL2 spans carrying wideband multimedia content. Complete with the HST-3000 along with the OneCheck Copper Test Suites, dualended testing with an UltraFED IIB is better and smarter, and makes it even simpler for providers to eliminate repeat dispatches by making sure tests are done right the first time.

Features:
  • With JDSU HST-3000 OneCheck, it provides diagnostics to quickly identify typical copper faults
  • Second-pair operation to accurately assess the effects of near-end and far-end crosstalk
  • Both manual and automated operation modes
  • Remote strap (short), open, drop battery and transmit tones, and trace tone
  • Supports wide frequency ranges from POTS (200 Hz) to VDSL2 (30 MHz)
  • Easily view pair endings with TDR Helper, which automatically shorts and opens the pair
  • New command mode lets technicians start and stop tests during execution without waiting for the previous test to complete
Key benefits:
  • Faster and more accurate than a single-ended test
  • Eliminate driving to change line conditions
  • Remotely set correct line terminations per technology
  • Built for the future ラ includes crosstalk tests for VDSL2 and ADSL2+ bonded pairs
  • Through-mode operation takes customers out of service only when necessary

Specifications:
General
Size 152 x 101 x 38 mm (6 x 4 x 1.6 in)
Weight 226.80 g (8 oz)
Battery life 20 hours of continuous use
Battery shelf life 2 months installed (20 hours of continuous use)
Operating temperature range ヨ18 to ヨ60°C (ヨ0 to 140°F)
Storage temperature range ヨ40 to ヨ75°C (ヨ40 to 165°F)
Humidity range 10 to 95% RH noncondensing
Tone transmit 200 Hz to 30 MHz ±0.015% at 0 dBm; trace tone (2 cadences)
Voiceband (POTS) frequency range 200 Hz to 20 kHz/600 O
Wideband (xDSL) frequency range 10 kHz to 30 MHz/100 O




For full JDSU UltraFED IIB product specifications, please click here: JDSU UltraFED IIB

JDSU UltraFED IIB 30 MHz Far End Device

For Use With HST-3000 & HST-3000C Mainframes
(HST-3000 & HST-3000C Mainframes Not Included In Sale!)

Technicians can remotely control the UltraFED IIB with the HST-3000 to test all DSL service varieties, including single- and bonded-pair VDSL2/ADSL2+ as well as legacy HDSL

HST 3000 3000c HST3000 HST3000c

JDSU UltraFED IIB Ultra Far End Device UltraFED-IIB Ultra Far End Device Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 37735-L/T*

  • JDSU UltraFED IIB Far End Device (BC# 37735-L/T*)
  • Instruction Booklet
  • Case For Unit
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!