Keysight Agilent N9038A 26.5GHz MXE EMI Receiver w/ Options
Condition: Refurbished / Calibrated
Warranty: 1 Year Warranty
Shipping: USA & Worldwide
- Keysight Agilent N9038A 26.5GHz MXE EMI Receiver w/ Options... (BC# -L/T*)
- Option PC4: Intel Core i7 CPU L 620 @ 2.00 GHz, 8GB
- Option EMC: Basic Electro-Magnetic Compatibility
- Option LSN: External LISN control upgrade
- Option NFE: Noise Floor Extension, Factory Alignment
- Option P26: Preamplifier, 26.5 GHz
- Option PFR: Precision Frequency Reference
- Option TDS: Time domain scans
- Option SSD: Additional Removable Solid-State Drive
- Option W7X: Windows Embedded Standard 7, 64 Bit OS
- Option N9060B-2FP: Spectrum Analyzer Measurement Application
- Option N9062A-2FP: RS FSP, FSU, FSE, SCPI Language Compatibility
- Option 526: Frequency Range, 3 Hz to 26.5 GHz
- Option CR3: Connector Rear, 2nd IF Output
- Option DP2: Digital Processor, 2GB Capture Memory
- Option EDP: Enhanced Display Package
- Power Cord
- User Manual On CD-ROM
Keysight Agilent N9038A 26.5GHz MXE EMI Receiver
The X-Series Difference Future-Ready
Optimize your investment and extend instrument longevity with upgradeable processor, memory, connectivity, and more to keep your test assets current today and tomorrow.
Consistent measurement framework
Achieve measurement integrity across your organization and drive more productivity in less time by leveraging a proven foundation for signal analysis and identical operation across the X-Series instruments.
Broadest set of applications
Address the changing demands of technology with additional measurement applications, the ability to run software inside the open Windows operating system, and a firstto-market track record in emerging standards.
Stay ready, stay in sync, and arrive ahead—with the Keysight X-Series.
Keep the Test Queue Flowing
In EMC testing, success depends on tools that can help you do more in less time—today and tomorrow. That’s why we created the MXE: it’s a standardscompliant EMI receiver and diagnostic signal analyzer built on an upgradeable platform. In the lab and on the bench, it provides the accuracy, repeatability, and reliability you need to test with confidence.
The MXE makes it easy to test in accordance with CISPR 16-1-1:2010 and MILSTD-461. Choose the frequency coverage you need—up to 3.6, 8.4, 26.5, or 44 GHz—and fully test devices with outstanding accuracy and excellent sensitivity across the required ranges.
Through the front panel or remotely with software, you can evaluate emissions and identify suspect signals using EMC measurements and a variety of intuitive displays. The extensive set of built-in analysis tools helps you diagnose the causes of noncompliant emissions
With all these capabilities and more, the MXE enables you and your team to keep the test queue flowing.
Extend instrument longevity with easy upgradability
To keep your instrument current and extend its longevity, the MXE offers easy upgradability of hardware and software capabilities. For example, you can enhance platform performance through CPU and memory upgrades, and add functionality with a simple license key
Leverage the proven reliability of a mature hardware platform
Uptime is essential in a test lab and that’s why we built the MXE on the robust Keysight X-Series signal analyzer platform. In addition, the MXE carries the benefits of Keysight’s standard three-year warranty and responsive service and support team.
Maximize Throughput in Compliance Testing
The MXE is ideally suited for high-performance EMC testing in commercial and military applications. The instrument offers a range of CISPR- and MIL-STDcompliant capabilities—detectors, bandwidths, and more—as well as features that further enhance the accuracy and throughput of EMC testing and data analysis
Simplify setup
The MXE contains a number of features that simplify the setup process for compliance measurements. For example, you can use setup tables to create specific measurement configurations for a variety of frequency ranges and antennas. You can also reduce overall setup time by saving and recalling frequently used custom instrument settings. In addition, the MXE can remotely control switching functions in external LISNs.
To accelerate identification of suspect emissions, access the built-in library of limit lines and activate the relevant regulatory limits. You can also define custom limit lines with the easy-to-use editor. To ensure appropriate limit testing, the MXE can automatically correct measured amplitudes for specific transducers, antennas, cabling, and external preamplifiers using customer configured amplitude correction files.
Accelerate data collection
The MXE is designed to help you see signal activity—quickly and easily—from multiple perspectives. The comprehensive user display allows you to see both a broad overview of the emissions environment and a detailed view of the signal amplitude at a single frequency.
Easily capture emissions data using built-in automated scan, search, and measure functions that mirror recommended commercial and military testing procedures. The multi-trace and max hold capabilities let you view emissions from the current position of the device under test (DUT) along with the maximum emissions from all DUT positions. During monitoring, the three color coded detectors are updated simultaneously to ensure accurate results.
Specifications | |
Frequency | 26.5GHz |
Frequency Options | 3.6, 8.4, 26.5, 44 GHz, Mixers to 1.1 THz |
Standard Attenuator Range | 70 dB |
Standard Attenuator Step | 2 dB |
Real-Time Bandwidth Options | 85 MHz |
DANL @1GHz | -167 dBm |
Maximum Analysis Bandwidth | 85 MHz |
Phase Noise @1 GHz (1 MHz offset) | -136 dBc/Hz |
Phase Noise @1 GHz (10 kHz offset) | -114 dBc/Hz |
Phase Noise @1 GHz (30 kHz offset) | -114 dBc/Hz |
Spur Free Dynamic Range | 76 dBc |
TOI @1 GHz (3rd Order Intercept) | N/A |
Applications Available | Yes |
Maximum Real-Time Bandwidth | 85 MHz |
Overall Amplitude Accuracy | ±.23 dB |
Bandwidth Options | 10 standard, 25, 85 MHz |
Performance Level | ◆◆◆◆◆◇ |
Application cellular | N/A |
Applications-Digital Video | N/A |
Applications-General Purpose | 89600 VSA Software Analog Demodulation Basic IQ Analysis CISPR 16-1-1 Compliant Commercial Military EMI Receiver MIL-STD-461 Compliant Noise Figure Phase Noise |
Applications-Wireless Connectivity | N/A |
Maximum Dynamic Range 3rd Order @1 GHz | N/A |
Minimum Duration for 100% Probability of Intercept | 3.7 μs |
Display Views | Density Spectrogram Density Spectrogram PvT (Power vs. Time) Spectrum PvT (Power vs. Time) Spectrogram PvT (Power vs Time) |
Triggering | FMT (Frequency Mask Trigger) TQT (Time Qualified Trigger) Level RF Burst Line External Periodic |
Applications with Frequency Mask Trigger | 89600 VSA Software Real-Time Spectrum Analyzer |
DANL @2 GHz, No Preamplifier | -150 dBm/Hz |
DANL @10 GHz, No Preamplifier | -151 dBm/Hz |
Benchtop | Yes |
Real Time Data Streaming | Yes |
For full Agilent N9038A EMI Receiver product specifications, please click here: N9038A