Now, there are ultrasonic flaw detectors with all the features you need for inspection in bright sunlight as well as in dark or poorly lighted conditions. Krautkramerメs new USN-L Series portable ultrasonic flaw detectors can be read easily in bright, direct sunlight. New モtransreflectiveヤ technology actually uses sunlight to make the display more visible outdoors. The new USN-L instruments have a fast 60 Hz update rate,LCD display and a fine screen resolution of 480 x 320 pixels. Backlighting is used for excellent visibility indoors or in dark conditions. The L Series instruments include the USN 50L and the USN 52L providing a choice of ultrasonic features to address individual applications. The R Series features our high resolution EL display and includes the USN 50R and the USN 52R instruments. They offer incredibly fine screen resolution for picking up the smallest details in critical echoes. Display resolution is nearly as sharp as analog displays.
Specifications:
Range |
From 5 to 5000 mm for steellong, continuously variable or variable in fixed steps |
|
Material velocity |
Continuously adjustable from 1000 to 9999 m/s, 2 programmable fixed values |
|
Pulse shift |
From -20 to +784 µs, depending on range setting |
|
Delay for digital time-of-flight measurement |
Approx. up to 999 ms (range dependent) | |
Gain |
From 0 to 110 dB variable in steps of 0.5 dB; fixed steps selectable between 0.1 / 0.5 / 1.0 / 2.0 / 6.0; variable step from 6.5 to 24 dB programmable in 0.1 dB steps |
|
Pulse repetition rate |
||
Setting |
REP-RATE |
Range (with 5920 m/s) |
HIGH |
905 Hz |
5 mm to 295 mm |
452 Hz |
296 mm to 589 mm |
|
226 Hz |
590 mm to 1178 mm |
|
113 Hz |
1179 mm to 5867 mm |
|
LOW |
452 Hz |
5 mm to 295 mm |
226 Hz |
296 mm to 589 mm |
|
113 Hz |
590 mm to 1178 mm |
|
56 Hz |
1179 mm to 5867 mm |
|
Test Modes |
Pulse-echo and Transmit/Receive (Dual) |
|
Pulser |
Spike/excitation pulse |
|
Damping |
50 ohms, 75 ohms, 150 ohms and 1000 ohms |
|
Display rectification |
Half-wave positive/negative, full-wave and RF |
|
Frequency (-3dB ranges) |
0.4 MHz to 10 MHz 2 MHz to 8 MHz 0.3 MHz to 4 MHz 3 MHz to 10 MHz |
|
Unit of Measure |
mm or inch |
|
Display |
USN 52R: EL display, 146 mm x 67 mm, 552 x 256 pixels USN 52L: transflective LCD display, 114 mm x 75 mm, 480 x 320 pixels, switchable backlight, selectable contrast Both versions: A-scan in a filled (SOLID) or curve (HOLLOW) mode, enlarged thickness reading selectable, status symbols for battery charge, pulser, measurement mode, lock and menu selection |
|
Refresh Rate |
60 Hz (REP-RATE = HIGH) 30 Hz (REP-RATE = LOW) |
|
Measurement Resolution |
Minimum: 0.1 mm or 0.5% display width |
|
Echo height resolution |
1% screen height |
|
Noise Suppression |
Adjustable from 0 to 80% screen height, absolutely linear, |
|
Language |
Either German, English, French, Spanish, Italian, Portuguese, Danish, Swedish, Norwegian, Finnish, Dutch and Russian |
|
Gate |
Variable over the whole sweep range in steps of 0.1 mm, alarm indication with flashing LEDs, threshold adjustment from 10 to 90% screen height, separate second monitor threshold for the multiecho measurement mode with controlled blocking and first echo start functions |
|
Measurement Modes |
Zero to first echo, multiple echo in gate with adjustable second threshold, time of flight to peak or flank in gate, amplitude evaluation as a % of screen height or as a dB difference to the reference echo up to 127%. dB reference value with reference gain data as well as gain changes as + or - values (indicated on display) |
|
Trigonometr.functions |
Automatic calculation and display of flaw position in angle beaming: • sound path • projection distance • reduced projection distance • depth • number of reflections (graphically) on flat and uniformly curved test objects up to a minimum diameter of 52 mm |
|
Data Memory |
Up to 140 instrument setups, storage of all instrument parameters and A-scan, presentation and printout of stored A-scans |
|
Data Logger |
Sequential storage of 2500 thickness readings with clear, review and direct report features, configurable up to 99 files, measured values for the corresponding files are determined by the file configuration |
|
DAC/TCG |
Recording of up to 9 reference echoes, dynamic range 40 dB, maximum slope 6 dB/µs, representation as Curve (DAC) and Time-Corrected Gain (TCG) |
|
Storage temperature |
From -40 °C to +75 °C |
|
Operating temperature |
From 0 °C to + 55 °C |
|
Interface |
RS 232 C, bidirectional for data transfer to a serial printer (EPSON format) or to a PC, or remote control of all settings from the PC |
|
Analog Output |
5V TTL switching voltage with gate alarm 0V to 2.5V analog voltage proportional to the echo amplitude 0V to 2.5V analog voltage proportional to the sound path of an echo in the gate |
|
Battery Mode |
6 AlMn or NiCad batteries (D-size) Operation period with fully charged NiCd batteries (5 Ah): USN 52R: 5.5 hours USN 52L: 10 hours |
|
Probe Connectors |
BNC or LEMO |
|
Weight |
2.7 kg including batteries |
|
Dimensions |
250 mm x 133 mm x 146 mm (W x D x H) |