LeCroy HDO6054 500MHz 4 Channel Oscilloscope

Combining Teledyne LeCroy’s HD4096 high definition 12-bit technology, with long memory, a compact form factor, 12.1” touch screen display, powerful measurement and analysis tools, and mixed signal capability, the HDO6000 is the ideal oscilloscope for circuit validation, system debug and waveform analysis. The powerful feature set provides analytical tools and unique application packages to streamline the testing process. Tools such as WaveScan Search and Find and History Mode, combined with advanced triggering, identify and isolate problems while Spectrum Analyzer Mode provides analysis tools in the frequency domain.

HD4096 Technology

HD4096 high definition technology consists of high sample rate 12-bitADCs, high signal-to-noise input amplifiers and a low-noise system architecture. This technology enables high definition oscilloscopes to capture and display signals of up to 1 GHz with high sample rate and 16 times more resolution than other oscilloscopes. Oscilloscopes with HD4096 technology have higher resolution and measurement precision than 8-bit alternatives. The high sample rate 12-bit ADCs provide high resolution sampling atup to 2.5 GS/s. The high performance input amplifiers deliver phenomenal signal fidelity with a 55 dB signal-to-noise ratio and provide a pristine signal to the ADC to be digitized. The low-noise signal architecture ensures that nothing interferes with the captured signal and the oscilloscope displays a waveform that accurately represents the signals from the device under test.

Long Memory

With up to 250 Mpts of memory the HDO6000 High Definition Oscilloscope scan capture large amounts of data with more precision than other oscilloscopes. The 2.5 GS/s, 250 Mpts architecture provides the ability to capture a fast transient or a long acquisition.

Large 12.1” Touch Screen

Navigating complicated user interfaces is a thing of the past thanks to the large touch screen display of the HDO6000.The user interface was designed for touch screens which makes navigating the HDO6000 extremely intuitive. 

Comprehensive Analysis Tools

Advanced math and measurement parameters quantify analog and digital waveforms while tracks, trends and histograms show how they change over time. Advanced triggering with Trigger Scan and Measurement Trigger ensure even the most complicated signals are captured.

Key Features

12-bit ADC resolution, up to15-bit with enhanced resolution

350 MHz, 500 MHz, and1 GHz bandwidths

Long Memory – up to 250 Mpts/Ch

12.1” touch screen display

Advanced Tools

Spectrum Analyzer Mode

WaveScan – Search and Find

LabNotebook Documentation and Report Generation

History Mode - Waveform Playback

Advanced Triggering with TriggerScan and Measurement Trigger

Power Analyzer Option

Serial Data Trigger, Decode and Debug Toolkit Options

16 Digital Channels with 1.25 GS/s

Analog and Digital
Cross-Pattern Triggering
Digital Pattern Search and Find
Analog and Digital Timing
Measurements
Logic Gate Emulation
Activity Indicators

Specifications

Analog - Vertical

Bandwidth@50Ω(-3dB)) 500MHz
Rise Time(10–90%,50Ω) 700 ps typical
Input Channels 4
Vertical Resolution 12-bits; up to15-bits with enhanced resolution (ERES)
Sensitivity 50 Ω:1mV/div–1V/div, fully variable1 MΩ:1mV/div–10V/div, fully variable
DC Gain Accuracy (Gain Component of DC Accuracy ±(0.5%)F.S,off set at 0V
Bandwidth Limiters 20MHz, 200MHz
Maximum Input Voltage 50 Ω:5Vrms,1MΩ: 400V max (DC+PeakAC≤10Khz)
Input Coupling 50 Ω:DC, GND;1MΩ:AC, DC, GND;
Input Impedance 50 Ω±2.0%;1MΩ±2.0%||15pF,
Offset Range 50 Ω:1mV-4.95mV:±1.6V,5mV-9.9mV:±4V,10mV-19.8mV:±8V,20mV-1V:±10V1 MΩ: 1mV-4.95mV:±1.6V,5mV-9.9mV:±4V,10mV-19.8mV:±8V,20mV-100mV:±16V, 102mV-198mV:±80V,200mV-1V:±160V,1.02V-10V:±400V
 DC Vertical Offset Accuracy ±(1.0% of offset value +0.5%FS+0.02% of max offset+1mV
Analog - Acquisition  
Sample Rate (Single-shot) 2.5GS/s
Sample Rate (Repetitive) 125GS/s,user selectable for repetitive signals (20ps/divto10ns/div
Record Length Standard-STD:50Mpts/ch(all channels)
Option-L:100Mpts/ch(all channels)
Option-XL:250Mpts/ch(all channels)
Acquisition Modes Real-time,Roll,RIS(Random Interleaved Sampling),Sequence(Segmented Memory up to 30,000segments,60,000 segments-LOption, 65,000-XLoption)with 1us intersegment dead-time
 Timebase Range 20ps/div-5ks/div with standard memory (up to 10ks/div with-L memory,25ks/div with-XL memory);RIS available at ≤ 10ns/div;Roll Mode available at ≥100ms/div and≤5MS/s
 Timebase Accuracy ±2.5ppm for 5 to 40C+1.0ppm/year from calibration
Channel-Channel Deskew Range ±9x time/div.setting,100ms max.,each channel
External Timebase Reference (Input) 10 MHz ±25 ppm at 0 to10dB min to 50Ω
External Timebase Reference (Output) 10MHz2.0dBm±1dBm,sine wave synchronous to scope timebase
External Clock DCto100MHz;(50Ω/1MΩ), ext.BNC input,Minimum rise time and amplitude requirements apply at low frequencies
Analog - Acquisition Processing  
Averaging Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps
 Enhanced Resolution (ERES) From 12.5- to 15-bits vertical resolution
Envelope (Extrema) Envelope, floor, or roof for up to 1 million sweeps
Interpolation Linear (Default) or Sinx/X
Triggering System  
Modes Auto, Normal, Single, Stop
Sources Any input channel, External, Ext/10, orline; slope and level unique to each source (except for line trigger)
Coupling  DC, AC, HFREJ, LFREJ
Pre-trigger Delay 0-100% of memory size
Post-trigger Delay 0-10,000 Divisions in real time mode, limited at slower time/div settings or in roll mode
Hold-off  From 2ns up to 20s or from 1 to 99,999,999 events
Internal Trigger Level Range ±4.1 div from center (typical
External Trigger Input Range Ext: ±400mV, Ext/10: ±4V
Maximum Trigger Rate 1M Triggers/sec (in Sequence Mode, up to 4 channels)
Trigger Sensitivity with Edge Trigger (Ch1–4 0.9 division: 10 MHz
1.0 divisions: 200 MHz
1.5 divisions: 250 MHz
2.0 divisions: 500 MHz
External Trigger Sensitivity, (Edge Trigger) 0.9 division: 10 MHz
1.0 divisions: 200 MHz
1.5 divisions: 250 MHz
2.0 divisions: 500 MHz
Max.Trigger Frequency,(C1-C4,Aux In,Smart Trigger) 500 MHz
Trigger and Interpolator Jitter ≤3.5 ps rms (typical) <0.1 ps rms (typical, software assisted)
Trigger Types  
Edge Triggers when signal meets slope (positive, negative, or either)and level condition
Width (Signal or Pattern) Triggers on positive or negative glitches with selectable widths selectable as low as 200ps (depending on oscilloscope bandwidth) ; Maximum Width: 20s
Pattern Logic combination (AND ,NAND, OR, NOR) of 5 inputs(4 channels and external trigger input). Each source can be high, low, or don’t care.  The High and Low level can be selected independently.Triggers at start or end of the pattern
Measurement Trigger Trigger on Measurement with qualified limits.
TV-Composite Video Triggers NTSC or PAL with selectable line and field; HDTV (720p, 1080i, 1080p) with selectable frame rate (50or60Hz) and Line; or CUSTOM with selectable Fields (1–8), Lines (upto2000), Frame Rates (25,30,50,or60Hz), Interlacing (1:1,2:1,4:1,8:1), or Synch Pulse Slope (Positive or Negative)
Smart Triggers  
Window Triggers when signal exits a window defined by adjustable thresholds
Interval (Signal or Pattern) Triggers on intervals selectable between 1ns and 20s
Glitch Triggers on positive or negative glitches with widths selectable as low as 200ps (depending on oscilloscope band-width)to 20s, or on intermittent faults
Dropout  Triggers if signal drops out for longer than selected time between 1ns and 20s
Runt Trigger on positive or negative runts defined by two voltage limits and two time limits.Select between 1ns and 20ns
Slew Rate Trigger on edge rates. Select limits ford V, dt, and slope. Select edge limits between 1ns and 20ns
Multi-Stage Triggers  
Cascade (Sequence) Triggering  
Capability Armon“A”event, then Trigger on“B”event.Or Armon“A”event, then Qualify on“B”event, and Trigger on“C”event.Or Armon“A”event, then Qualify on“B”then“C”event, and Trigger on“D”event
Types A,B,C, or Devent: Edge, Glitch, Width, Window, Dropout, Interval, Runt, Slew Rate,Pattern (analog), or Measurement.
Holdoff Hold off between A and B, Band C, C or D, or any is selectable by time or number of events
Qualified First In Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Hold off between sources is selectable by time or events
Qualified Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events
Triggerscan A Trigger Trainer analyzes the wave forms, identifies normal behavior, and then sets up alarge set of rare event smart trigger setups that target abnormal behavior. The trainer ‘learns’ trigger setups based on slew rates, periods, amplitudes outside of a range and then applies them sequentially.
Triggers with Exclusion Technology Glitch, Width, Interval, Runt, SlewRate-Trigger on intermittent faults by specifying the expected behavior and trig-gering when that condition is not met
Measurement Tools  
Measurement Functionality Display any 8 parameters together with statistics, including their average, high, low, and standard deviations. Histicons provide a fast, dynamic view of parameters and wave shape characteristics. Parameter Math allows addition, subtraction, multiplication, or division of two different parameters. Parameter gates define the location on the source waveform. Each occurrence of each parameter is measured and added to the statistics table.
Measurement Parameters Amplitude, Area, Base (Low), Cycles, Data, Delay, Delta Delay,Duty Cycle, Duration, Fall time (90–10%,80–20%,@level), Frequency, First, Last, Level @x, Maximum, Mean, Median, Minimum, Narrow band phase, Narrow band power, Number of points, +Overshoot, –Overshoot, Peak-to-peak, Period, Risetime (10–90%,20–80%,@level), RMS, Std.deviation, Top, Width, Median, Phase, Time @ minimum (min.), Time @ maximum (max.), Delta time @ level, Delta time @ level from trigger, X @max., X @min., Cycle-Cycle Jitter, N-Cycle, N-Cycle with start selection, Frequency @ level, Period @ level, Half Period, Width @level, Time Interval Error @ level, Setup, Hold, Skew, Duty Cycle @ level, Duty Cycle Error, Edge @ lv(countsedges)
Math Tools  
Math Functionality Display up to 8 math function traces (F1–F8).The easy-to-use graphical interface simplifies setup of up to two operations on each function trace, and function traces can be chained together to perform math-on-math.
Math Operators Absolute value, Average (summed), Average (continuous), Correlation (two waveforms), Cubic interpolation, Derivative, Deskew (resample), Difference (–), Enhanced resolution (to15bitsvertical), Envelope, Exp(base), Exp(base10), FFT (power spectrum, magnitude, phase, power density, real, imaginary, magnitude squared, up to 128Mpts and rectangular, VonHann, Hamming, Flat To pad Blackman Harris windows), Floor, Integral, Interpolate (cubic, quadratic, sinx/x), Invert (negate) ,Log (basee),Log (base10), Product(x), Reciprocal, Rescale (with units), Roof, (SINx)/x,Sparse, Square, Square root, Sum(+), Zoom (identity). 2 dual operator math functions may be defined at a time
Measurement and Math Integration  
  Histograms expanded with 19 histogram parameters and up to 2 billion events Trend(data log)of up to 1 million events Track graphs of all parameters Persistence histogram, persistence trace (mean,range,sigma)
Pass/Fail Testing  
Test Types Parameter limit testing, mask testing. Pass/Fail Actions include: Save, Stop, Alarm, Pulse, Hardcopy, LabNotebook)
Probes  
Standard Probes PP018 (5 mm) (Qty. 4)
Probing System BNC and Teledyne LeCroy Pro Bus for Active voltage, current and differential probes
Display System  
Display Size Color 12.1" wide screen flat panel TFT-Active Matrix with high resolution touch screen
Display Resolution WXGA; 1280 x 800 pixels
Number of Traced Display a maximum of 16 traces. Simultaneously display channel, zoom, memory and math traces
Grid Styles Auto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y, Tandem, Quattro, Twelve, Sixteen
Waveform Representation Sample dots joined, or sample dots only
Connectivity  
Ethernet Port (2)10/100/1000 Base-T Ethernet interface (RJ-45connector)
USB Host Ports (6) USB Ports Total–(2) Front USB Ports
USB Device Port (1)USBTMC Port
GPIB Port (Optional) Supports IEEE – 488.2 (External)
External Monitor Port Standard 15-pin D-Type SVGA-compatible DB-15 connector, DVI connector and HDMI connector
Remote Control Via Windows Automation, orvia Teledyne LeCroy Remote Command Set
Processor/CPU  
Type Intel Core i5, 2.5GHz (or better)
Processor Memory 8 GB standard
Operating System Windows® Embedded Standard 7 Professional, 64-bit
Power Requirements  
Voltage 100–240 VAC ±10% at 45–66Hz; 100–120VAC ±10% at380–420Hz; Automatic AC Voltage Selection; Installation Category: 300 V CAT II
Power Consumption (Nominal) 200W / 200V
Max Power Consumption 350 W / 350 VA(with all PC peripherals and active probes connected to 4 channels)
Environmental  
Temperature Operating: 5°C to 40°C; Non-Operating:-20°C to 60°C
Humidity Operating: 5% to 90% relative humidity (non-condensing) up to +31°C, Upper limit deratesto 50% relative humidity (non-condensing) at+40°C; Non-Operating: 5% to 95% relative humidity (non-condensing)as tested per MIL-PRF-28800F
Altitude Operating: 3,048m (10,000ft) maxat ≤30C; Non-Operating: Up to 12,192 meters (40,000ft)
Random Vibration Operating : 0.31 grms 5Hz to 500Hz, 15 minutes in each of three orthogonal axes; Non-Operating: 2.4 grms 5Hz to 500Hz, 15 minutes in each of three orthogonal axes
Functional Shock 30 g peak, half sine,11ms pulse,3 shocks (positive and negative)in each of three orthogonal axes,18 shock stotal
 
Physical  
Dimensions (HWD) 11.48”H x 15.72”W x 5.17”D (291.7 mm x 399.4 mm x 131.31
Weight 5.86 kg (12.9 lbs)
Certifications  
CE Certifications Low Voltage Directive 2006/95/ECEN61010-1:2010,EN61010-2-030:2010
EMC Directive 2004/108/EC EN61326-1:2006, EN61326-2-1:2006
UL and cUL Listing UL61010-1 (3rd Edition), UL61010-2-030 (1st Edition) CAN/CSA C22.2 No.61010-1-12
Warranty and Service 3-year warranty; calibration recommended annually. Optional service programs include extended warranty, upgrades,and calibration services

 

For full LeCroy HDO6054 Oscilloscope product specifications, please click here: HDO6054

LeCroy HDO6054 500 MHz 4 Channel Oscilloscope

Combining Teledyne LeCroy’s HD4096 high definition 12-bit technology, with long memory, a compact form factor, 12.1” touch screen display, powerful measurement and analysis tools, and mixed signal capability, the HDO6000 is the ideal oscilloscope for circuit validation, system debug and waveform analysis.

HD4096 high definition technology consists of high sample rate 12-bit ADCs, high signal-to-noise ratio amplifiers and a low-noise system architecture. This technology enables high definition oscilloscopes to capture and display signals of up to 1 GHz with high sample rate and 16 times more resolution than other oscilloscopes.

Includes Accessories As Listed!

BC# -L/T*

LeCroy HDO6054 HDO-6054 Oscilloscope Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.



  • LeCroy HDO6054 Oscilloscope (BC# -L/T*)
  • Power Cord
  • User Manual On CD-ROM