Huntron Tracker 2700 unit with accessories

Huntron Tracker 2000 Electronic Component Tester Circuit Analyzer

megger s1-1068 looking stop down

Megger Bite 2 Battery Impedance Analyzer Tester

Megger MCT1605 Automatic Current Transformer Saturation Ratio Polarity Tester

$18,069.00
Availability: In stock
SKU
MG27

Condition: Refurbished

Warranty: 1 Year Warranty

Megger MCT1605 Current Transformer Test Set

  • One button automated test
  • Displays multiple instantaneous Saturation Curves with Knee Point
  • Integrated 1 kV DC insulation test system
  • “Save & Print Later” with USB stick
  • Fast data entry using full QWERTY keyboard
  • 1600 VAC Saturation Test Voltage

The Megger MCT1605 test set is a lightweight, robust, portable unit used to automatically or manually perform saturation, ratio, polarity, demagnetizing tests and insulation tests on current transformers. The MCT provides a microprocessor controlled variable voltage output and precision instrumentation for automatically testing single and multi-ratio CTs. The MCT1605 possesses microprocessor controlled output voltage with precision instrumentation and storage, reducing testing time and increasing productivity. The MCT1605 will directly connect to multi ratio CT’s and perform all three tests - saturation, ratio and polarity - on all taps with the push of a button and without changing leads. The MCT1605 has a large display, permitting the user to easily read all pertinent data while the test is being performed and providing the ability to view the current transformer’s saturation curve.

Current transformers can be tested in their equipment configuration, such as being mounted in transformers, oil circuit breakers or switchgear. It is necessary for the equipment to be completely isolated from the electrical system prior to testing.

 

Saturation Test

 

With the single push of a button, The MCT1605 performs a CT saturation test and calculates the rated knee point. The saturation test is performed at mains rated frequency of 50 or 60 Hz as required by IEC regulations. The MCT1605 will calculate the rated knee point in compliance with IEEE C57.13.1, IEC 60044-1 or IEC 60044-6. While the saturation test is being performed, The MCT will plot the CT saturation curve on the large graphical display and automatically provide the user with the rated knee point per the desired IEEE or IEC standard. Many substation CT’s include a multi-ratio secondary, therefore the MCT1605 has the ability to plot and simultaneously display up to 10 CT saturation curves.

 

Ratio Test

 

Ratio testing is performed by comparing a voltage applied to the secondary winding to the resulting voltage produced on the primary winding. For example, if 1 volt per turn is applied to the secondary winding, the voltage present on the primary winding would be 1 volt. More specifically, if 120 volts were applied to the secondary of a 600/5 current transformer (120:1 ratio), 1 volt would be present on the primary winding. This test is performed automatically during a CT saturation test or manually with the output control knob and metering display. The MCT1605 will also provide the operator with a direct reading ratio, thus removing the need to calculate CT ratio manually.

 

Polarity Test

 

Polarity of the current transformer under test is indicated to the operator by a simple “Correct” or “Incorrect” indication on the display accompanied by the measured phase angle.

 

Demagnetization

 

Normal operating conditions and typical winding resistance measurements can cause a CT to become magnetized. The MCT1605 has the ability to automatically demagnetize the CT under test. This automatic demagnetization routine is useful to ensure that the CT Saturation test yield correct results. Prior to testing demagnification is recommended per ANSI C57.13.1.

 

CT Burden Measurement

 

In addition to performing any required CT test, the MCT1605 has the ability to measure the actual connected Burden. When the actual measured burden is compared against the calculated burden, the user confirms that the CT will operate with published rating.

 

Insulation Resistance Test

 

In order to ensure that the CT secondary wiring is properly insulated, the MCT1605 system includes a 500/1000V insulation resistance test system. This test ensures that the CT secondary winding and secondary wiring is properly insulated per ANSI C57.13.1.

The MCT1605 will also automatically switch the test leads to perform all required insulation test. These test include H-L, H-G, L-G Note: Disconnect all electronic loads before performing this test.

 

Winding Resistance

 

Measuring the DC resistance of transformer windings will aid in identifying problems such as shorted or open windings as well as loose connections.

 

Data Storage and Printing

 

The MCT1605 test system not only permits accurate and automated CT testing, but also catalogues and stores test results within the instrument for simple retrieval by software at a later date. All catalogued test results can be uploaded to Megger’s PowerDBTM Lite for report generation and saturation curve plotting on a computer. PowerDB Lite also has the ability to operate the MCT1605 with no operator intervention, thus providing a completely computer controlled automated test system.


Specifications:

Input 100 to 265 V, 1ø, 50 or 60 Hz, 15 A max.
Output Continuously variable in four ranges:
0 to 40 V at 2.0 A max (5 minute on 15 minute off)
0 to 40 V at 5 A max for burden test
0 to 160 V at 2.0 A max (5 minute on 15 minute off)
0 to 800 V at 1.5 A max (3 min on, 15 min off)
0 to 1600 V at 1.0 A max (3 min on, 15 min off)
Voltmeters  
Output 4 1⁄2 digit, auto ranging
Resolution 0.0000 to 1.9999/19.999/199.99/1999.9
Ranges 0 to 40/160/800/1600 V
Accuracy ±0.5% of reading, and ±.5% range typical
±1% of reading and ±1 V maximum
Input 4 1⁄2 digit, auto-ranging
Ranges 0 to 2/600
Resolution 0.0000 to 1.9999/19.999/199.99/600 V
Accuracy 2 V Range: ±0.5% of reading and ±0.25% range
600 V Range: ±0.5% of reading and ±0.5% range
Ammeter  
Range 0.0000 to 1.0000A/5.000
Accuracy ±0.85% of reading and ±1 LSD
Phase Angle  
Range 0 to 360 degrees
Accuracy ±1 degree
Ratio  
Range 0.8 to 5000
Accuracy ±0.4% typical
±0.8% maximum
Ratio Test Frequency 55Hz internally generated providing a universal 50/60Hz test set
Winding Resistance Measuring Range: .01Ω to 99.9Ω
Accuracy: <9.99Ω ±3% of reading ±2 digits
< 99.9Ω ±5% of reading ±2 digits
Insulation Test  
Test Voltage: 1000 VDC, 500 VDC
Measuring Range: 10kΩ – 999MΩ
Short Circuit Current: 1.5mA nominal
Test Current on Load: 1mA at min. pass values of insulation
(as specified in BS7671, HD 384 and IEC 364)
Accuracy ±3%, ±2 digits up to 10MΩ
±5%, up to 100MΩ
±30% up to full scale
Communication Interfaces Ethernet/USB
Environment Operating: -10º C to 40º C
Storage: -30º C to 70º C
Enclosure The unit is housed in a rugged enclosure suitable for use in outdoor substations
Standards IEC 61010, CSA 22.2, CE
Dimensions 7.5” H X 19.25” W X 15” D
(190 H X 489 W X 940 D mm
Weight 47.6 lb (21.6 kg)

 

Megger MCT1605 Current Transformer Test Set

The Megger MCT1605 test set is a lightweight, robust, portable unit used to automatically or manually perform saturation, ratio, polarity, demagnetizing tests and insulation tests on current transformers.

Includes Accessories As Listed

Megger MCT1605 Current Transformer Test Set Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

  • Megger MCT1605 Current Transformer Test Set
  • Lead Set
  • User Manual on CDROM
  • Power Cord
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!