Megger S1-1052 10 kV High Current Insulation Resistance Tester

$3,559.00
Availability: In stock
SKU
MG12

Condition: Refurbished / Calibrated

Warranty: 1 Year Warranty

Megger S1-1052 Insulation Resistance Tester

The new 5 & 10 kV insulation resistance testers from Megger are designed specifically to assist you with the testing and maintenance of high voltage electrical equipment. IEEE 43-2000 recommends the use of 10 kV for motor windings rated above 12 kV and the Megger S1-1052 facilitates this. The case is incredibly rugged and easy to carry, being made of tough polypropylene and achieving an ingress protection rating of IP65. In addition, the model number is marked on both sides of the case for ease of identification in stores or vehicles.

The instruments have a large easy to read backlit LCD display making it equally suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time of the test is displayed constantly, removing the need for separate timers. Adjustable timers and limit alarms are included.

The instrument can test when being powered by the mains or its internal rechargeable battery, a great benefit when site conditions are unknown or long term testing is required.

The controls of the instrument are clear and unambiguous and a "quick start" guide is included in the lid of the instrument removing the need to carry bulky manuals under site conditions.

The instrument is fitted with a guard terminal to enhance accuracy. The guard test lead is included as standard with the instrument.

To further enhance the flexibility of the instruments both have the facility to set the test voltage in steps from 50 V to the maximum output voltage avoiding the expense of several insulation resistance testers to meet your application needs.

These IR instruments are designed to meet the highest safety standards and meet the requirements of EN61010. In addition, the instrument measures the voltage at the terminals and if this is above 50 V then the instrument will display the high voltage warning and inhibit testing. At the end of the test the instrument will automatically discharge the energy transferred to the equipment during the test phase.

The S1-552 and S1-1052 are equally suited to routine testing and diagnostic regimes being pre-programmed with IR, PI, DAR, SV and DD profiles.

 

Specifications:

Voltage input range 85-265 V rms, 50/60Hz, 60 VA
S1-1052 battery life 4 hours continuous testing at 10 kV
S1-1052 test voltages 50 V to 1 kV in 10 V steps, 1 kV to 10 kV in 25 V steps
S1-1052 accuracy (23ºC, 10 kV) ±5% to 2 TΩ
±20% to 20 TΩ
Guard 2% error guarding 500 kΩ leakage with 100 MΩ load
Display range Digital display (3 digits) 10 kΩ to 15 TΩ (S1-552) to 35 TΩ (S1-1052)
Analogue display 100 kΩ to 1 TΩ
Short circuit/charge current 5 mA @ 5 kV ( S1-552) or 10 kV (S1-1052)
Capacitor charge time <3 seconds per µF at 5mA to 10 kV
Capacitor discharge time <250ms per µF to discharge from 10000 V to 50 V
Capacitance measurement (above 500 V) 10 nF to 50 µF (dependent on measurement voltage)
Capacitance measurement accuracy (23°C) ±5% ±5 nF
Voltage output accuracy (0°C to 30°C) +4%, -0%, ±10 V of nominal test voltage at 1 GΩ load
Current measurement range 0.01 nA to 5 mA
Current measurement accuracy (23°C) ±5% ±0.2 nA at all voltages
Interference rejection 1 mA per 600 V up to a maximum of 2 mA
Timer range Up to 99 minutes and 59 seconds from start of test 15 second minimum setting for test voltage ≥1000 V 30 second minimum setting for test voltage <1000 V
Memory capacity 32kB
Test regimes Auto IR, PI, DAR, SV and DD.
Interface RS232 and USB
Data store Voltage, test time, leakage current, resistance, PI, DAR, DD, capacitance and time constant
Real time output Serial, once per second of test voltage, current and resistance
Operating temperature -10°C to 50°C
Storage temperature -25°C to 65°C
Ingress protection (lid closed) IP65
Humidity 90% RH non-condensing at 40°C
Safety Meets the requirements of EN61010-1:2001 CATIII 300 V
EMC Meets the requirements of EN61326-1:1998 for use in heavy industrial areas
Dimensions 305 x 194 x 360 mm (12.7 x 6 x 14.2 inches)
Weight 7.1 kg (16lb) approx.
For full Megger S1-1052 Insulation Tester product specifications, please click here: Megger S1-1052

Megger S1-1052 10kV High Current Insulation Resistance Tester

Designed specifically to assist you with the testing and maintenance of high voltage electrical equipment.

Suited to routine testing and diagnostic regimes being pre-programmed with IR, PI, DAR, SV and DD profiles.

Includes Accessories As Listed

BC# -L/T*

Megger S1-1052 S11052 High Insulation Resistance Tester Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

  • Megger S1-1052 10kV Insulation Resistance Tester (BC# -L/T*)
  • 3M Lead Set
  • RS232 PC Interface Cable
  • USB PC Interface Cable
  • User Guide On CD-ROM
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!