- Noyes OLS2 SingleMode Dual Laser Source (BC# 41679-L/T*)
- SM Source:
- 1310nm
- 1550nm
- ST Connector For Source
- SM Source:
- Noyes OPM 4-4D SingleMode MultiMode Optical Power Meter (BC# 41678-L/T*)
- Power Meter:
- 850nm
- 980nm
- 1310nm
- 1490nm
- 1550nm
- 1625nm
- ST Connector For Power Meter
- Power Meter:
- (2) SM ST-ST Fiber Optic Cables
- (4) Fiber Wipes
- User Manual On CD-ROM
- Carrying Case (G)
Request a Quote for
Noyes SLP 4-6D SM Fiber Test Kit
The SLP 4-6D test kit combines the OPM 4-4D optical power meter and OLS 2-Dual LASER light source and is ideally suited for testing single-mode fiber optic networks. The OLS 2-Dual features 1310 nm and 1550 nm LASER output from a single output port and is easy to operate. The LASER output is stabilized to ensure accurate test results per current TIA/EIA requirements. This light source offers 4 modes of operation: Dual wavelengths sending ID, single wavelength sending ID, CW, and modulated Tone. [Active Output], [Tone], [Battery], and [External Power] indicators identify the currently enabled operating mode, battery charge status, and external power presence. The output port is equipped with a removable SC (FC & ST available) adapter to allow the output connector to be inspected and cleaned.
The OPM 4-4D offers Wave ID, automatic wavelength identification and switching, when used with the OLS 2-Dual. Multiple test Tone detection is provided for fiber identification. The OPM 4-4D stores optical references for each calibrated wavelength. An easy to read Dual Wavelength LCD display with Backlight shows measured power [dBm or µW] or insertion loss [dB], calibrated wavelengths, tone signal [Hz], wavelength ID, and the battery charge status.
In addition to being powered by two AA alkaline, the OPM 4-4D or OLS 2-Dual can be powered by optional AC adapter and/or rechargeable NiMH battery pack. The OPM 4-4D optical input port accepts Noyes thread-on style adapter caps. Adapter caps are required for operation and must be ordered separately. The OPM 4-4D and OLS 2-Dual are fully N.I.S.T. traceable.
Features:
For full Noyes SLP 4-6D product specifications, please click here: Noyes SLP 4-6D
The SLP 4-6D test kit combines the OPM 4-4D optical power meter and OLS 2-Dual LASER light source and is ideally suited for testing single-mode fiber optic networks. The OLS 2-Dual features 1310 nm and 1550 nm LASER output from a single output port and is easy to operate. The LASER output is stabilized to ensure accurate test results per current TIA/EIA requirements. This light source offers 4 modes of operation: Dual wavelengths sending ID, single wavelength sending ID, CW, and modulated Tone. [Active Output], [Tone], [Battery], and [External Power] indicators identify the currently enabled operating mode, battery charge status, and external power presence. The output port is equipped with a removable SC (FC & ST available) adapter to allow the output connector to be inspected and cleaned.
The OPM 4-4D offers Wave ID, automatic wavelength identification and switching, when used with the OLS 2-Dual. Multiple test Tone detection is provided for fiber identification. The OPM 4-4D stores optical references for each calibrated wavelength. An easy to read Dual Wavelength LCD display with Backlight shows measured power [dBm or µW] or insertion loss [dB], calibrated wavelengths, tone signal [Hz], wavelength ID, and the battery charge status.
In addition to being powered by two AA alkaline, the OPM 4-4D or OLS 2-Dual can be powered by optional AC adapter and/or rechargeable NiMH battery pack. The OPM 4-4D optical input port accepts Noyes thread-on style adapter caps. Adapter caps are required for operation and must be ordered separately. The OPM 4-4D and OLS 2-Dual are fully N.I.S.T. traceable.
Features:
- Rugged, handheld, lightweight
- Designed for field use
- Certify single-mode links per TIA/EIA standards
- Wave ID - automatic wavelength identification and switching
- Dual Wave ID, single Wave ID, CW, and modulated Tone (on single-mode output)
- 270 Hz, 330 Hz, 1 kHz, and 2 kHz Tone
- Adjustable output
- Large LCD with backlight
- Power measurements in dBm or µW; insertion loss in dB
- Reference power level storage
- AA alkaline, optional rechargeable NiMH battery pack or AC Adapter
- Low battery indicator
- Cost-effective, easy to use
- N.I.S.T traceable
OLS 2 - Dual specifications | |
Output wavelength | 1310 ± 20nm, 1550 ± 20nm |
Output Power | 0 dBm ( Adjustable 2 dB ) |
Laser classification | Class 1 (FDA 21 CFG 1040.10 and 1040.11, and IEC 60825-1) |
Output connector | SC (FC & ST available) |
Spectral width (FWHM) | 5 nm (max) |
Stability | ± 0.05 dB over 1 hours (after 15 min. warm-up) ± 0.1 dB over 8 hours (after 15 min. warm-up) |
General | |
Power | 2 x AA batteries, optional NiMH or AC adapter |
Battery life (2 x AA) | Typical 120 hours, Minimum 75 hours |
Operating temperature | -10 to 50°C, 90% RH (non-condensing) |
Storage temperature | -30 to 60°C, 90% RH (non-condensing) |
Size (H x W x D) | 5.5 x 3.2 x 1.5 in (14.0 x 8.1 x 3.8 cm) |
Weight | 0.65 lb (.29 kg) |
OPM 4-4D specifications | |
Calibrated wavelengths | 850, 980, 1310, 1490, 1550, 1625 nm |
Detector type | Filtered InGaAs |
Measurement range | +26 to -50 dBm |
Tone detect range | +6 to -30 dBm +6 to -25 dBm for 850 nm |
Wavelength ID range | +6 to -30 dBm +6 to -25 dBm for 850nm |
Accuracy | ± 0.25 dB |
Resolution | 0.01 dB |
Measurement units | dB, dBm, µW |
General | |
Power | 2 x AA batteries, optional NiMH |
Battery life (2 x AA) | 300 hours with backlight [Off] 20 hours with backlight [On] |
Operating temperature | -10 to 50°C, 90% RH (non-condensing) |
Storage temperature | -30 to 60°C, 90% RH (non-condensing) |
Size (H x W x D) | 5.5 x 3.2 x 1.5 in (14.0 x 8.1 x 3.8 cm) |
Weight | 0.58 lb (0.26 kg) |
For full Noyes SLP 4-6D product specifications, please click here: Noyes SLP 4-6D