Fluke 80i-500S AC Clamp-On Current Probe
Condition: Refurbished
Warranty: 1 YEAR WARRANTY
The Fluke 80i-500s is a clamp-on current probe that is designed to reproduce current waveforms found in modern commercial and industrial power distribution systems. The probe’s performance is optimized for accurate reproduction of currents at line frequency and up to the 50th harmonic. The 80i-500s is also compatible with any instrument capable of millivolt measurements.
- Ideal for measuring distorted current waveforms and associated harmonics.
- Allows measurement of currents from 1 to 500A ac rms, 5 Hz to 10 kHz without breaking into the circuit.
- Provides an output of 1 mV ac per 1 amp ac.
- A passive filter eliminates noise and ring on rapidly rising waveforms, ensuring accurate reproduction on oscilloscope displays.
- Rated for 600V circuits of Overvoltage Category III per IEC 1010-1. (See “Safety Specifications” for an explanation of Overvoltage Categories.)
Specifications | |||
ELECTRICAL SPECIFICATIONS | |||
Current Range: | 1A to 500A ac rms. | ||
AC Current Over Range Limit: | Up to 700A ac rms for maximum of 10 minutes, followed by removal from current carrying conductor for at least 30 minutes. | ||
Output Signal: | 1 mV ac/A ac | ||
Influence of Temperature on Accuracy: | <0.15% per 10°C (18°F) for temperatures from -10 to 18°C (14 to 64°F) and from 28 to 50°C (82 to 122°F). | ||
Basic Accuracy (45 to 65 Hz): | |||
Input Curent: | 1 to 20A | 20 to 100A | 100 to 500A |
Error: | 5% of rdg + 0.3A | 5% of rdg | ±3° |
Phase Shift: | 100 to 500A | 2% of rdg | ±1° |
Extended Accuracy: | For other frequencies, refer to the appropriate input current range and add the error listed below to the “Basic Accuracy” error | ||
Input Current: | Error: | ||
(5 to 10 Hz): | 1 to 500A | not specified* | |
(10 to 20 Hz): | 1 to 300A | 5% | |
300 to 400A | 15% | ||
400 to 500A | 25% | ||
(20 to 45 Hz): | 1 to 500A | 5% | |
(65 Hz to 3 kHz): | 1 to 50A | 5%+0.4A | |
50 to 500A | 5% | ||
(3 kHz to 10 kHz): | 1 to 500A | not specified* | |
*-3 db @ 5 Hz and 10 kHz typical | |||
Input Load Impedance (of host instrument): | >1MΩ in parallel with up to 47 pF | ||
dV/dt max: | 0.24 mV/µsec | ||
Rise or Fall Time: | <40 µsec | ||
Working Voltage: | 600V ac rms, in compliance with IEC-1010-1. | ||
Common Mode Voltage: | 600V ac rms from earth ground, in compliance with IEC 1010-1. | ||
Influence of Adjacent Conductor: | <5 mA/A | ||
Influence of Conductor Position in Jaw Opening: | +/-(1.5% of reading +0.1A). |
Fluke 80i-500S AC Clamp-On Current Probe
The Fluke 80i-500s is a clamp-on current probe that is designed to reproduce current waveforms found in modern commercial and industrial power distribution systems.
(Not Included In This Sale)
Allows measurement of currents from 1 to 500A ac rms, 5 Hz to 10 kHz without breaking into the circuit.
The Fluke 80i-500s is a clamp-on current probe that is designed to reproduce current waveforms found in modern commercial and industrial power distribution systems.
Fluke 80i-500S 80i500S 80i 500S Clamp On Current Probe Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.
BC# 23464M-L/T*
- Fluke 80i-500S AC Current Clamp Probe (BC# 23464M-L/T*)