The Fluke 434 three-phase power quality meter help you locate, predict, prevent and troubleshoot problems in power distribution systems. These easy-to-use power quality tools are a モmust haveヤ for any person who maintains or troubleshoots three phase power. The new IEC Class A standards for flicker and power quality are built right in to take the guess work out of power monitoring.
Applications
Frontline troubleshooting ヨ quickly diagnose problems on-screen to get your operation back online
Predictive maintenance ヨ detect and prevent power quality issues before they cause downtime
Quality of service compliance ヨ validate incoming power quality at the service entrance
Long-term analysis ヨ uncover hard-to-find or intermittent issues
Load studies ヨ verify electrical system capacity before adding loads
Energy assessments ヨ quantify energy consumption before and after improvements to justify energy saving devices
Features:
Troubleshoot real-time: Analyze the trends using the cursors and zoom toolsラeven while background recording continues
Highest safety rating in the industry: 600 V Cat IV/1000 V CAT III rated for use at the service entrance
Automatic transient mode: Captures 200 kHz waveform data on all phases simultaneously: Up to 6 kV
Fully Class A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class A standard
Measure all three phases and neutral: With included four current probes
AutoTrend: Every measurement you see is always automatically recorded, without any setup
System-monitor: Up to seven power quality parameters on one screen according to EN50160 power quality standard
Inrush mode: For troubleshooting nuisance circuit breaker tripping
View graphs and generate reports: With included analysis software
Logger function: Configure for any test condition with memory for over 400 parameters at user defined intervals
Mains signaling: Measure interference from ripple control signals at specific frequencies
Battery Life: Seven hours operating time per charge on NiMH battery pack
Warranty: Rugged, handheld troubleshooter with 90 Day warranty
Technical Data
Inputs
Number:
4 voltage and current (3 phases + neutral)
Maximum voltage:
1000 Vrms (6 kV peak)
Maximum sampling speed:
200 kS/s on each channel simultaneously
Volt/Amps/Hertz
Vrms (AC + DC)
Measurement range:
1 ... 1000 V
Accuracy:
0.1% of Vnom
Vpeak
Measurement range:
1 ... 1400 V
Accuracy:
5% of Vnom
Crest factor, voltage
Measurement range:
1.0 ... > 2.8
Accuracy:
±5%
Arms (AC + DC)
Measurement range:
0 ... 20 kA
Accuracy:
±0.5% ± 5 counts
Apeak
Measurement range:
0 ... 5.5 kA
Accuracy:
5%
Crest factor, A
Measurement range:
1 ... 10
Accuracy:
±5%
Hz 50 Hz nominal
Measurement range:
40 ... 70 Hz
Accuracy:
±0.01 Hz
Dips and swells
Vrms (AC+DC) ²
Measurement range:
0.0% ナ 100% of Vnom
Accuracy:
±0.2% of nominal voltage
Arms (AC+DC) ²
Measurement range:
0 ... 20 kA ?
Accuracy:
±1% ± 5 counts
Harmonics
Harmonic (interharmonic) (n)
Measurement range:
DC, 1..50; (Off, 1..49) measured according to IEC 61000-4-7
Vrms
Measurement range:
0.0 ナ 1000 V
Accuracy:
±0.05% of nominal voltage
Arms
Measurement range:
0.0 ナ 4000 mV x clamp scaling
Accuracy:
±5% ± 5 counts
Watts
Measurement range:
Depends on clamp scaling and voltage
Accuracy:
±5% ± n x 2% or reading, ± 10 counts
DC voltage
Measurement range:
0.0 ナ 1000 V
Accuracy:
±0.2% of nominal voltage
THD
Measurement range:
0.0 ナ 100.0%
Accuracy:
±2.5% V and A (± 5% Watt)
Hz
Measurement range:
0 ナ 3500 Hz
Accuracy:
± 1 Hz
Phase angle
Measurement range:
-360º ... +360º
Accuracy:
± n × 1.5º
Power and energy
Watt, VA, VAR
Measurement range:
1.0 ナ 20.00 MVA¹
Accuracy:
±1% ± counts
kWh, kVAh, kVARh
Measurement range:
00.00 ナ200.0 GVAh¹
Accuracy:
± 1.5% ± 10 counts
Power Factor/ Cos ? / DPF
Measurement range:
0ナ1
Accuracy:
± 0.03
Flicker
Pst (1 min), Pst, Plt, PF5
Measurement range:
0.00 ナ 20.00
Accuracy:
±5%
Unbalance
Volts
Measurement range:
0.0 ナ 5.0%
Accuracy:
±0.5%
Current
Measurement range:
0.0 ナ 20%
Accuracy:
± 1%
Transient Capture
Volts
Measurement range:
±6000 V
Accuracy:
±2.5% of Vrms
Minimum detect duration
5 µs (200kS/s sampling)
Inrush mode
Arms (AC+DC)
Measurement range:
0.000 ナ 20.00 kA¹
Accuracy:
±1% of meas ± 5 counts
Inrush duration (selectable)
Measurement range:
7.5 s ... 30 min
Accuracy:
±20 ms (Fnom = 50 Hz)
Autotrend recording
Sampling:
5 readings/sec continuous sampling per channel
Memory:
1800 min, max and avg points for each reading
Recording time:
Up to 450 days
Zoom:
Up to 12x horizontal zoom
Memory
Screens & data:
50, shared memory divided between logging, screens and data sets
Notes
¹
Depending on clamp scaling
?²
Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle
For full Fluke 434 product specifications, please click here: Fluke 434