Fluke 345 Single Phase Power Quality Clamp Meter

Fluke 345 Single Phase Power Quality Clamp Meter

Fluke 437 Series II Three Phase Power Quality Analyzer Energy Meter

Fluke 437 Series II Three Phase Power Quality Analyzer Energy Meter

Fluke 434 Three Phase Power Quality Analyzer Meter

$2,199.00
Availability: In stock
SKU
PQ03

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

Shipping: USA & Worldwide

  • Fluke 434 HandHeld Power Quality Analyzer (BC# 41305-L/T*)
    • Installed Options:
      • Transients
      • Inrush
      • Interharmonics
      • Energy
      • Memory
      • Mains Signaling
  • (4) Fluke i400S AC Current Clamps
  • AC Adapter/Charger
  • User Manual On CD-ROM
  • Carrying Case (G)
Request a Quote for

Have questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

We are commited to win your business!

The Fluke 434 three-phase power quality meter help you locate, predict, prevent and troubleshoot problems in power distribution systems. These easy-to-use power quality tools are a モmust haveヤ for any person who maintains or troubleshoots three phase power. The new IEC Class A standards for flicker and power quality are built right in to take the guess work out of power monitoring.

Applications

  • Frontline troubleshooting ヨ quickly diagnose problems on-screen to get your operation back online
  • Predictive maintenance ヨ detect and prevent power quality issues before they cause downtime
  • Quality of service compliance ヨ validate incoming power quality at the service entrance
  • Long-term analysis ヨ uncover hard-to-find or intermittent issues
  • Load studies ヨ verify electrical system capacity before adding loads
  • Energy assessments ヨ quantify energy consumption before and after improvements to justify energy saving devices

Features:

  • Troubleshoot real-time: Analyze the trends using the cursors and zoom toolsラeven while background recording continues
  • Highest safety rating in the industry: 600 V Cat IV/1000 V CAT III rated for use at the service entrance
  • Automatic transient mode: Captures 200 kHz waveform data on all phases simultaneously: Up to 6 kV
  • Fully Class A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class A standard
  • Measure all three phases and neutral: With included four current probes
  • AutoTrend: Every measurement you see is always automatically recorded, without any setup
  • System-monitor: Up to seven power quality parameters on one screen according to EN50160 power quality standard
  • Inrush mode: For troubleshooting nuisance circuit breaker tripping
  • View graphs and generate reports: With included analysis software
  • Logger function: Configure for any test condition with memory for over 400 parameters at user defined intervals
  • Mains signaling: Measure interference from ripple control signals at specific frequencies
  • Battery Life: Seven hours operating time per charge on NiMH battery pack
  • Warranty: Rugged, handheld troubleshooter with 90 Day warranty

Technical Data
Inputs
Number:  4 voltage and current (3 phases + neutral)
Maximum voltage:  1000 Vrms (6 kV peak)
Maximum sampling speed:  200 kS/s on each channel simultaneously
Volt/Amps/Hertz
Vrms (AC + DC)
Measurement range:  1 ... 1000 V
Accuracy:  0.1% of Vnom
Vpeak
Measurement range:  1 ... 1400 V
Accuracy:  5% of Vnom
Crest factor, voltage
Measurement range:  1.0 ... > 2.8
Accuracy:  ±5%
Arms (AC + DC)
Measurement range:  0 ... 20 kA
Accuracy:  ±0.5% ± 5 counts
Apeak
Measurement range:  0 ... 5.5 kA
Accuracy:  5%
Crest factor, A
Measurement range:  1 ... 10
Accuracy:  ±5%
Hz 50 Hz nominal
Measurement range:  40 ... 70 Hz
Accuracy:  ±0.01 Hz
Dips and swells
Vrms (AC+DC) ²
Measurement range:  0.0% ナ 100% of Vnom
Accuracy:  ±0.2% of nominal voltage
Arms (AC+DC) ²
Measurement range:  0 ... 20 kA ?
Accuracy:  ±1% ± 5 counts
Harmonics
Harmonic (interharmonic) (n)
Measurement range:  DC, 1..50; (Off, 1..49) measured according to IEC 61000-4-7
Vrms
Measurement range:  0.0 ナ 1000 V
Accuracy:  ±0.05% of nominal voltage
Arms
Measurement range:  0.0 ナ 4000 mV x clamp scaling
Accuracy:  ±5% ± 5 counts
Watts
Measurement range:  Depends on clamp scaling and voltage
Accuracy:  ±5% ± n x 2% or reading, ± 10 counts
DC voltage
Measurement range:  0.0 ナ 1000 V
Accuracy:  ±0.2% of nominal voltage
THD
Measurement range:  0.0 ナ 100.0%
Accuracy:  ±2.5% V and A (± 5% Watt)
Hz
Measurement range:  0 ナ 3500 Hz
Accuracy:  ± 1 Hz
Phase angle
Measurement range:  -360º ... +360º
Accuracy:  ± n × 1.5º
Power and energy
Watt, VA, VAR
Measurement range:  1.0 ナ 20.00 MVA¹
Accuracy:  ±1% ± counts
kWh, kVAh, kVARh
Measurement range:  00.00 ナ200.0 GVAh¹
Accuracy:  ± 1.5% ± 10 counts
Power Factor/ Cos ? / DPF
Measurement range:  0ナ1
Accuracy:  ± 0.03
Flicker
Pst (1 min), Pst, Plt, PF5
Measurement range:  0.00 ナ 20.00
Accuracy:  ±5%
Unbalance
Volts
Measurement range:  0.0 ナ 5.0%
Accuracy:  ±0.5%
Current
Measurement range:  0.0 ナ 20%
Accuracy:  ± 1%
Transient Capture
Volts
Measurement range:  ±6000 V
Accuracy:  ±2.5% of Vrms
Minimum detect duration  5 µs (200kS/s sampling)
Inrush mode
Arms (AC+DC)
Measurement range:  0.000 ナ 20.00 kA¹
Accuracy:  ±1% of meas ± 5 counts
Inrush duration (selectable)
Measurement range:  7.5 s ... 30 min
Accuracy:  ±20 ms (Fnom = 50 Hz)
Autotrend recording
Sampling:  5 readings/sec continuous sampling per channel
Memory:  1800 min, max and avg points for each reading
Recording time:  Up to 450 days
Zoom:  Up to 12x horizontal zoom
Memory
Screens & data:  50, shared memory divided between logging, screens and data sets
Notes
¹  Depending on clamp scaling
 Value is measured over 1 cycle, commencing at a fundamental zero crossing, and refreshed each half-cycle



For full Fluke 434 product specifications, please click here: Fluke 434