Features

  • ±1.0 dB Accuracy On board noise source provides precision calibration. Accuracy is guaranteed over time and temperature at all frequencies and power levels.
  • Pass-Fail Installation Check Check your entire system or just your favorite channels. On screen report summarizes results.
  • Digital Channel Measurement Check average power of digital channels. View flatness across the entire channel. Measures QAM, QPSK, VSB & QPR.
  • Ingress Analysis Automatically searches reverse band for ingress. Peak hold function catches intermittent problems.
  • Data Recording One button recording makes documentation easy. Automatically performs 24 HR FCC testing. Downloads directly to printer or to a computer.
  • Self Calibrating No need for costly calibrations Unit is self calibrating
  • Made in USA

Specifications Technical Frequency Range:  5-872 MHz
Accuracy:  ±20 KHz
Resolution:  125KHz
IF Bandwidth:  280KHz

Level Measurement
Range:  -30 ± 60 dBmV
Accuracy:  ± 1.0 dB at 77° F ± 2.0 dB Total (0° - 120° F)
Resolution:  0.1 dB
Ingress Sweep:  Sweeps Sub Band in 250 KHz steps.

Digital Channel Measurement
Average Power:  ± 1.8 dB at 77° F
Accuracy:  ± 2.8 dB Total (0° - 120° F)
Type:  QAM, QPSK, VSN and QPR

Auto Calibration
Noise Source Stability:  0.2 dB 0° - 120° F Measurements corrected for power level, frequency and temperature.


Automated Testing
Scan Rate:  6 Carriers/sec
Storage:  >40 Scans of 135 Channels each.
Range:  50dB
Accuracy:  ± 2.0 dB at 77° F (± 3.0 dB 0° - 120° F)

HUM
Range:  0 - 5%
Filter:  20 - 200 Hz
Tilt:  Automatically calculated from user selected carriers.
Audio:  Adjustable volume, waterproof mylar speaker.

General
Physical Dimensions:  4.25" x 10" x 2.75"/ 11 cm x 25.5 cm x 7cm
Weight:  3 lbs (1.4Kg) including case & batteries.
Operating Temp:  0° - 120° F (-18° to 49°C)
Storage Temp:  -4° to 140° F (-20° to 60° C)
Battery:  Type 6 Sub C Cells
Charge Time:  4 Hours
Battery Life:  4 hours Continuous (backlight off)
Electronic Shut-Off:  Saves power extends operating time
Standard Channel Plans:  NTSC, HRC, IRC, AIR (VHF,UHF), PAL, Custom plans available on request.




For full Sadelco Displaymax 800 product specifications, please click here: Sadelco Displaymax 800

Sadelco DisplayMax 800 Signal Level CATV Meter

Frequency Range: 5 - 872 MHz, Self Calibrating, Data Recording, Ingress Analysis, Digital Channel Measurement

Includes Carrying Case & Accessories As Listed
Sadelco DisplayMax 800 CATV Meter DisplayMax-800 CATV Meter Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.