Sonatest SiteScan 250S Digital Ultrasonic Flaw Detector 250 S
$4,519.00
Availability:
Out of stock
SKU
UF05
Condition: Refurbished/Calibrated
Warranty: 1 Year Warranty
Shipping: USA & Worldwide
Request a Quote for
- Sonatest Sitescan 250S Ultrasonic Flaw Detector (BC#-L/T*)
- AC Adapter/Charger
- User Manual on CDROM
- Carrying Case (G)
Specifications:
| Test Range | 0-5mm (0.2in) up to 0-10000 (400in) at steel velocity. Variable in sequence, 10mm or 1mm |
| Velocity | 1000 - 9999 m/s |
| Probe Zero | 0 - 999.999 us |
| Delay | 0 - 10000m at steel velocity in 0.05 steps (0 - 400 in 0.002 in steps) |
| Gain | 0 - 110dB in 0.5, 1, 2, 6, 10, 14, 20 dB steps |
| Test Modes | Pulse echo and transmit-receive |
| Gates | Two fully independent gates for echo monitoring and thickness measurement. Start and width adjustable over full range of unit, amplitude variable from 0 to 100% FSH. Bar presentation. Positive or negative triggering for each gate with audible and visual alarms. |
| Measurement Modes | |
| Depth | Depth and amplitude of signal in gate |
| Echo - Echo | Echo - Echo distance, automatic gate 2 position |
| Gate to Gate |
Echo - Echo distance, manual gate 2 position |
| Trig | Trigonometric display of beam path, depth and surface distance Calculation of skip depth and curve surface compensation, X-offset for transducer |
| T-Min | Holds minimum thickness in depth mode |
| Pulser Voltage | -200 volt peak amplitude, rise/fall time <10ns into 50 ohm |
| Pulser Width | Fixed 100ns 30 - 250 ns linked to filter band |
| Pulser Repetition Frequency | Selectable 5 - 1000Hz. |
| Display | Colour transflective TFT Display area 111.4 x 83.5mm (4.39 x 3.29 in) A-scan area 315 x 200 max Variable brightness Sunlight viewable 8 Selectable colour schemes for A-scan & menu |
| Screen Update Rate | 50 or 60Hz |
| Rectification | Full Wave, positive, negative, RF |
| Frequency Bands | Broadband 1 - 10 Mhz (-6dB) |
| Vertical Linearity | 1% full screen height |
| Amplifier Linearity | +- 0.1 dB |
| Horizontal Linearity | 0.33% full screen width |
| Reject | 50% Suppressive LED warning light when activated |
| Waveform Smoothing | Produces a smooth signal envelope |
| Units | mm, inches or time |
| AGC | Automatic Gain Control sets selected echo to a user defined level (10-90%) |
| DAC | Up to 10 points may be entered and used to digitally draw a DAC curve Reference -2, -6, -10, -12, -14 dB curves can be selected for JIS, ASME and EN1714 codes |
| AWS | Automatic defect sizing in accordance with AWS D1.1 Structural Welding Code |
| API | Automatic defect sizing in accordance with API 5UE |
| AVG/DGS | Automatic defect sizing using probe data |
| TCG |
Time corrected Gain 40dB dynamic range, 30dB per microsecond, up to 10 points for curve definition. |
| A-scan Memory | 800 waveforms |
| Panel Memory | 100 stores for calibration setting |
| Thickness Logging | 8000 readings stored in Block/Location/Number coding or alpha-numeric pre-programmed work sheets Transferable to Excel using optional SDMS |
| Auto-Cal | Automatic calibration with two echoes |
| Reference Waveform | Recalled waveform can be shown in a different colour to live waveform for direct comparison |
| Display Freeze | Holds current waveform on screen |
| Peak Memory | For echo-dynamic pattern capture |
| Front USB | For connection to PC, keyboard and printer |
| Outputs | Serial Interface, composite video (PAL & NTSC), analogue output for amplitude and distance updated at PRF rate Transmitter sync output |
| Battery | Lithium Ion 14.4V 5.0 ampere hours Up to 16 hours, indication of battery charge. Recharge time 4 hours. Mains pack option |
| Charger | 100 - 240 VAC, 50-60Hz |
| Environmental | Meets IP67 |
| Temperature Range | Operating -10o C to 55o C (14o F - 131o F) Storage -40o C to 75o C (-40o F to 167o F) |
| Size | 256 x 145 x 145mm (10 x 5.7 x 5.7 in.) |