Tektronix THS3014 100MHz Handheld Oscilloscope
$2,379.00
Availability:
In stock
SKU
11H54
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- Tektronix THS3014 100MHz Four Channel Oscilloscope 2.5 GS/s (BC# 32926-L/T*)
- (4) Tektronix 300 MHz 10X Voltage Probe Sets
- THP0301-M
- THP0301-G
- THP0301-Y
- THP0301-B
- THS 3000 Series Installation & Safety Instructions
- AC Adapter/Charger
- Power Cord
- USB PC Interface Cable
- Strap For Unit
- User Manual On CD-ROM
- Carrying Case w/ Strap
Request a Quote for
Tektronix THS3014 100MHz Four Channel Oscilloscope
With 4 isolated channels and up to 7 hours of battery life, the lightweight THS3000 Handheld Oscilloscope Series enables you to safely make floating or differential measurements on your bench or in the field. Now you can tackle tough environments with the performance you expect from Tektronix - safely and affordably.
Accurately measure your signals
With up to 100 MHz bandwidth, 4 channels, and 2.5 GS/s maximum sample rate, no other oscilloscope offers as much bandwidth and sample rate in a portable handheld form factor. The THS3014 Handheld Oscilloscope Series has 10,000 points record length per channel, enabling you to capture more signal information at higher sample rates to clearly see signal details. For applications where it is important to measure slow-changing signals over long time periods, the THS3000 Series offers Roll mode that extends the record length to 30,000 points of signal information.
Safely make floating and differential measurements
Making accurate and safe measurements on power electronics, power semiconductors, and other electronics applications can be challenging when the signal reference is floating and not referenced to earth ground. When your signal ranges from low voltage to high voltage (kV) or you must use probing techniques that can potentially create ground loops, the problem is compounded.
To enable floating measurements, the THS3000 Series is architecturally different than most other oscilloscopes. All input channels are fully isolated from the main chassis and from each other. Additionally the power adapter and USB interface are fully isolated to ensure safe measurements and eliminate the risk of unintentional grounding or accidental short circuits. When configured with the proper probes you can be assured you'll be able to make quick, safe, and accurate measurements.
Fast analysis of your device
The THS3000 Handheld Oscilloscope Series is packed with analysis tools to help you validate your device's operation and identify issues quickly. With waveform math, you can add, subtract, or multiply any of your signals to investigate instantaneous power or look at gain. Vertical and horizontal cursors allow you to look at a specific point on your waveform for accurate measurements of voltage, current, time, or frequency. With 21 automated measurements, you can make common measurements quickly and accurately. The built-in Fast Fourier Transform (FFT) function allows you to see the frequency spectrum of your signal, revealing signal interference, crosstalk, or switching noise.
Find intermittent faults with TrendPlotル
Intermittent faults can be caused by timing errors, temperature changes, environmental influences, or simply broken wiring or connectors. The TrendPlotル function helps you find those faults by plotting minimum and maximum measurement values over time. You can select up to 4 measurements and plot any combination of voltages, amps, frequency, time, and phase for any or all four inputs, all with time capture information.
Waveform limit testing
The THS3000 Series can automatically monitor your signals and output Pass or Fail results by judging whether the input waveform is within predefined boundaries. User selections can include testing one or all input channels and automatic recording of Pass or Fail data. Data can easily be reviewed using the Replay mode or stored externally to a USB memory device.
Automatic capture and data logging of 100 display screens
Capturing random or changing signals can often be difficult. The THS3000 Series greatly simplifies any type of waveform data logging by continuously capturing 100 display screens. Each screen capture can include multiple channels and math waveforms, each with its own time stamp. Data capture can also be tailored to specific events by selection of qualified trigger conditions. Playback is quick and easy with the automatic replay of all captured screens or only the screens you select.
Complete solution for power measurements
For performing power measurement on motor drives, power converters/inverters, and power semiconductor devices the THS3000 Series is equipped to handle most common measurements. For basic debugging, the isolated input channels can be used with a variety of voltage and current probes. Each input channel can be configured to match the probe type and attenuation ensuring correct measurements and cursor readings. Four channels allow for easy measurements of three-phase power or simultaneous capture of digital control and power signals.
Measurements on power conversion electronics usually require probes with higher voltage ratings. Tektronix offers a passive probe with insulation systems specifically designed for making floating measurements. The THP0301-X can measure up to 849 Vp-p (300 VRMS). Optional P5122 probes, when coupled with the THS3000 Series, are suitable for making measurements on 1000 VRMS devices in Category II environments, with a maximum float voltage of up to 600 VRMS relative to earth ground.
Intuitive operation
The THS3000 Handheld Oscilloscope Series has a front-panel layout and an intuitive user interface which makes the instrument easy to use, reducing learning time and increasing efficiency. For initial setup or for situations where you're constantly changing connection points, the THS3000 Series has a single-button Autoset and Autorange feature which can automatically set up the trigger system and adjust vertical and/or horizontal oscilloscope settings.
Easy to use
The bright color display makes it easy for you to see the signals you're measuring. Each waveform is color coded and designed to correspond to the colors on the input probe connectors, the front-panel channel selector buttons, and the individual probes which are colored at both ends. By matching the colors during setup you'll be assured you can easily identify your waveforms.
For setup assistance user messages are available in 11 user-selectable languages including English, French, German, Spanish, Portuguese, Italian, Japanese, Simplified and Traditional Chinese, Korean, and Russian.
Features:
Applications:
Specifications:
For full Tektronix THS3014 product specifications, please click here: Tektronix THS3014
With 4 isolated channels and up to 7 hours of battery life, the lightweight THS3000 Handheld Oscilloscope Series enables you to safely make floating or differential measurements on your bench or in the field. Now you can tackle tough environments with the performance you expect from Tektronix - safely and affordably.
Accurately measure your signals
With up to 100 MHz bandwidth, 4 channels, and 2.5 GS/s maximum sample rate, no other oscilloscope offers as much bandwidth and sample rate in a portable handheld form factor. The THS3014 Handheld Oscilloscope Series has 10,000 points record length per channel, enabling you to capture more signal information at higher sample rates to clearly see signal details. For applications where it is important to measure slow-changing signals over long time periods, the THS3000 Series offers Roll mode that extends the record length to 30,000 points of signal information.
Safely make floating and differential measurements
Making accurate and safe measurements on power electronics, power semiconductors, and other electronics applications can be challenging when the signal reference is floating and not referenced to earth ground. When your signal ranges from low voltage to high voltage (kV) or you must use probing techniques that can potentially create ground loops, the problem is compounded.
To enable floating measurements, the THS3000 Series is architecturally different than most other oscilloscopes. All input channels are fully isolated from the main chassis and from each other. Additionally the power adapter and USB interface are fully isolated to ensure safe measurements and eliminate the risk of unintentional grounding or accidental short circuits. When configured with the proper probes you can be assured you'll be able to make quick, safe, and accurate measurements.
Fast analysis of your device
The THS3000 Handheld Oscilloscope Series is packed with analysis tools to help you validate your device's operation and identify issues quickly. With waveform math, you can add, subtract, or multiply any of your signals to investigate instantaneous power or look at gain. Vertical and horizontal cursors allow you to look at a specific point on your waveform for accurate measurements of voltage, current, time, or frequency. With 21 automated measurements, you can make common measurements quickly and accurately. The built-in Fast Fourier Transform (FFT) function allows you to see the frequency spectrum of your signal, revealing signal interference, crosstalk, or switching noise.
Find intermittent faults with TrendPlotル
Intermittent faults can be caused by timing errors, temperature changes, environmental influences, or simply broken wiring or connectors. The TrendPlotル function helps you find those faults by plotting minimum and maximum measurement values over time. You can select up to 4 measurements and plot any combination of voltages, amps, frequency, time, and phase for any or all four inputs, all with time capture information.
Waveform limit testing
The THS3000 Series can automatically monitor your signals and output Pass or Fail results by judging whether the input waveform is within predefined boundaries. User selections can include testing one or all input channels and automatic recording of Pass or Fail data. Data can easily be reviewed using the Replay mode or stored externally to a USB memory device.
Automatic capture and data logging of 100 display screens
Capturing random or changing signals can often be difficult. The THS3000 Series greatly simplifies any type of waveform data logging by continuously capturing 100 display screens. Each screen capture can include multiple channels and math waveforms, each with its own time stamp. Data capture can also be tailored to specific events by selection of qualified trigger conditions. Playback is quick and easy with the automatic replay of all captured screens or only the screens you select.
Complete solution for power measurements
For performing power measurement on motor drives, power converters/inverters, and power semiconductor devices the THS3000 Series is equipped to handle most common measurements. For basic debugging, the isolated input channels can be used with a variety of voltage and current probes. Each input channel can be configured to match the probe type and attenuation ensuring correct measurements and cursor readings. Four channels allow for easy measurements of three-phase power or simultaneous capture of digital control and power signals.
Measurements on power conversion electronics usually require probes with higher voltage ratings. Tektronix offers a passive probe with insulation systems specifically designed for making floating measurements. The THP0301-X can measure up to 849 Vp-p (300 VRMS). Optional P5122 probes, when coupled with the THS3000 Series, are suitable for making measurements on 1000 VRMS devices in Category II environments, with a maximum float voltage of up to 600 VRMS relative to earth ground.
Intuitive operation
The THS3000 Handheld Oscilloscope Series has a front-panel layout and an intuitive user interface which makes the instrument easy to use, reducing learning time and increasing efficiency. For initial setup or for situations where you're constantly changing connection points, the THS3000 Series has a single-button Autoset and Autorange feature which can automatically set up the trigger system and adjust vertical and/or horizontal oscilloscope settings.
Easy to use
The bright color display makes it easy for you to see the signals you're measuring. Each waveform is color coded and designed to correspond to the colors on the input probe connectors, the front-panel channel selector buttons, and the individual probes which are colored at both ends. By matching the colors during setup you'll be assured you can easily identify your waveforms.
For setup assistance user messages are available in 11 user-selectable languages including English, French, German, Spanish, Portuguese, Italian, Japanese, Simplified and Traditional Chinese, Korean, and Russian.
Features:
- 21 automatic measurements
- Waveform math and FFT spectral analysis
- Volts, time, frequency, watts cursor measurements
- Measurement data logging with TrendPlotル
- Waveform pass/fail limit testing
- Automatic 100 display screens recorder
- 6 in. (153 mm) bright color display
- USB device and host support
- 7 hours of continuous battery operation
Applications:
- Embedded analog and digital design
- Power devices, power electronics, and power supply design
- Automotive and avionics design and maintenance
- Industrial equipment design and installation
- Field test and service
Specifications:
Isolated input channels | 4 |
Analog bandwidth (-3 dB) | 100 MHz |
Rise time | 3.5 ns |
Hardware bandwidth limits | 20kHz, 20 MHz, or full |
Float voltage | 1000 VRMS CAT II / 600 VRMS CAT III from BNC shell to earth ground |
Maximum sample rate | 2.5 GS/s (1.25 GS/s 4-ch) |
Maximum record length (all channels) | 10,000 points (30,000 points in roll mode (4 ms to 2 min / div)) |
Vertical system | |
Input coupling | AC, DC |
Input impedance | 1 MO ±1%, 14 pF ±2 pF |
Input sensitivity range | 2 mV/div to 100 v/div |
Vertical resolution | 8 bits |
DC gain accuracy | ±2.1% of reading +0.04 × range/div for 5 mV/div to 100 V/div |
Max BNC input voltage | (1 MO) 300 VRMS CAT III from BNC signal to BNC shell |
Max probe voltage (with THP0301-X probe) | 300 VRMS CAT III from 10:1 probe tip signal to BNC and reference lead |
Trace positioning | ±4 divisions |
Horizontal system | |
Time base range (s/div) | 2 ns to 4 s |
Delay time range | 1 full screen (12 divisions) of pre-trigger or up to 100 screens (1,200 divisions) of post-trigger |
Timing accuracy | ±100 ppm + 0.04 div |
Zoom | Horizontally expand or compress a live or stopped waveform |
Trigger system | |
Input source | Channel 1, 2, 3, or 4. All input references isolated from each other and earth ground |
Main trigger modes | Auto-level, Auto, Normal, and Single |
Trigger coupling | DC, HF reject, Noise reject (reduces sensitivity) |
Trigger sensitivity, internal DC coupled | 0.5 divisions from DC to 5 MHz at >5 mV/div 1 divisions >5 MHz to 100 MHz |
Trigger level range | ±4.0 divisions |
Trigger modes Edge Pulse width |
Positive, negative, or dual slope on any input channel. Coupling includes DC, HF reject, and Noise reject Trigger on channel 1, width of positive or negative pulses (glitches) that are >, <, =, or ? a specified period of time (resolution of 0.01 div with minimum time of 50 ns) |
Event | Trigger on n-th occurrence of trigger (N selectable from 2 to 99) |
Video | Trigger on channel 1, line number, all lines, odd, even, or all fields on NTSC, PAL, PAL plus, and SECAM signals |
Non-interlaced | Trigger on channel 1, high-res non-interlaced video with line frequencies from 14 kHz to 65 kHz |
Acquisition modes | |
Sample (default) | Acquire sampled values |
Glitch detect | Captures high frequency or glitches as narrow as 8 ns from 5 µs to 120 s / div |
Averaging | Selectable from 2, 4, 8, or 64 waveforms |
Roll | Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 4 ms/div |
Data recorder | Automatic data logging of 100 triggered records (screens) with date and time stamp. store internally or to a USB device |
Waveform compare | Visually compare against user-definable reference waveforms or perform automatic pass or fail testing of 1 to 4 channels with data logging of test results |
Automatic setup | |
Autoset | Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems |
Autorange | Continuous auto-setup of vertical, horizontal, and trigger systems that track signal changes |
Waveform measurements | |
Cursors | Time, freq (1/T), volts, watts, Rise/Fall time from any input channel or math waveform |
Automatic measurements | 21. Up to 4 can be displayed on-screen at any one time. Measurements include: V DC, V ACRMS, V AC+DC, VPeak Max, VPeak Min, Peak to Peak, A DC, A AC, A AC+DC, Frequency, Rise time (using cursors), Fall time (using cursors), Phase (between any 2 inputs), Positive pulse width, Negative pulse width, Positive duty cycle, Negative duty cycle, dBV, dBm into 50 O and 600 O |
TrendPlotル | Records and graphically displays any 4 automatic scope measurements. store internally or to USB flash drive for recall and analysis |
Waveform math | |
Arithmetic | Add, subtract, and multiply waveforms |
FFT | Spectral magnitude. Set FFT vertical scale to Linear or Logarithmic, and FFT window to Automatic, Hamming, Hanning, or None |
Display system | |
Display type | 6 in. (153 mm) liquid-crystal color display |
Display resolution | 320 horizontal × 240 vertical pixels |
Waveform style | Vectors (dot-join), Dots, Envelope, Variable persistence, Infinite persistence |
Display format | YT and XY |
Storage memory | |
Reference | 4 user-definable reference traces |
Waveform | Stores 30 internal scope records (4 traces each) with screen image and corresponding setup |
Recording | Store 10 internal recordings that can be a 100-screen replay sequence, a roll-mode recording, or a TrendPlotル measurement recording |
Screen image | Store up to 9 internally or 256 BMP images to an external USB storage drive |
Real-time clock | Time and date stamp of all stored data |
Input/Output ports | |
USB host port | Supports USB mass storage devices |
USB device port | Mini-USB-B connector allows for communication/control of oscilloscope |
Probe compensator output Amplitude Frequency |
Side-panel output ヨ 1.225 Vp-p 500 Hz |
Kensignton-style lock | Side-panel security slot connects to standard Kensington-style lock |
Power source | |
Battery | 7 hour, 10.8 v rechargeable Li-Ion battery |
Battery charging time | 5 hours |
Line power | AC power adapter/charger |
Power source voltage | 100 v to 240 v AC ±10% |
Power source frequency | 50 hz to 60 hz |
Physical characteristics | |
Dimension Height Width Depth |
265 mm (10.5 in.) 190 mm (7.5 in.) 70 mm (2.8 in.) |
Weight Net Shipping (base model) Shipping (TK model) |
2.2 kg (4.8 lb.) 4.7 kg (10.4 lb.) 7.8 kg (17.1 lb.) |
Environmental | |
Enclosure | IP 41 according to IEC60529S |
Temperature Operating Nonoperating |
0 °C to +40 °C (with battery) 0 °C to +50 °C (without battery) ヨ20 °C to +60 °C |
Humidity Operating Nonoperating |
0 °C to 10 °C, noncondensing 10 °C to 30 °C, up to 95% relative humidity 30 °C to 40 °C, up to 75% relative humidity 40 °C to 50 °C, up to 45% relative humidity ヨ20 °C to 60 °C, relative humidity, noncondensing |
Altitude Operating Nonoperating |
Up to 3,000 m (9,843 ft.) Up to 12,000 m (39,370 ft.) |
Vibration/Shock Operating Nonoperating |
Vibration (Sinusoidal): 3 g max, according to MIL-PRF-28800F, class 2 Shock: 30 g max, according to MIL-PRF-28800F, class 2 Vibration (Random): 0.03 g2/Hz, according to MIL-PRF-28800F, class 2 |
Regulatory Electromagnetic compatibility Safety |
EN 61326-1:2006, EN 61326-2-1:2006 for emission and immunity UL61010-1:2004; CAN/CSA C22.2 No. 61010.1-04; EN61010-1:2001, Pollution degree 2; ANSI/ISA-82.02.01 |
For full Tektronix THS3014 product specifications, please click here: Tektronix THS3014