Vivax Metrotech VM-810 Locator Kit (VM 810 Transmitter & Locator)
Condition: Refurbished/Calibrated
Warranty: 1 Year Warranty
Shipping: USA & Worldwide
- Vivax Metrotech VM-810 Locator (BC# 9518A-L/T*)
- Vivax Metrotech VM-810 Transmitter (BC# 9518B-L/T*)
Vivax Metrotech VM-810 Transmitter & Receiver Overview
Using the correct frequency makes a world of difference when locating buried utilities. The depth of the utility, size, material, and amount of congestion (proximity of other utilities) all need to be taken into consideration for the correct frequency selection. Large diameter, direct buried pipes with bell housing ends that use insulators and rubber gaskets, such as water or gas require a higher frequency while smaller diameter, well-grounded direct buried or long distance in conduits work, better with a lower frequency.
The VM-810 operates at 83.1kHz which is ideal for water and gas utilities which generally are larger pipes with bell housings and gaskets. The VM-810’s higher frequency is also good for locating ungrounded small diameter drop wires and inducing signals through the soil, onto services when direct connecting is not an option.
Key Features:
* Simple – Single button operation
* Intuitive – Distance Sensitive Left/Right GuidanceTM
* Efficient – “Real Time” fully automatic gain
* Accurate – Depth and current readout
* Compact – Lightweight rugged design
The Simplicity of One-Button Locating
Using the correct frequency makes a world of difference when locating buried utilities. The depth of the utility, size, material, and amount of congestion (proximity of other utilities) all need to be taken into consideration for the correct frequency selection. Large diameter, direct buried pipes with bell housing ends that use insulators and rubber gaskets, such as water or gas require a higher frequency while smaller diameter, well-grounded direct buried or long distance in conduits work better with a lower frequency. Tthe VM-810 has sonde modes to aid in the location of non-metallic pipes and ducts.
The VM-810 operates at 83.1kHz which is ideal for water and gas utilities which generally are larger pipes with bell housings and gaskets. The VM-810’s higher frequency is also good for locating ungrounded small diameter drop wires and inducing signals through the soil, onto services when direct connecting is not an option.
Simultaneous Peak/Null - Saves You Time
The combination of Left/Right Guidance, signal strength, audio tone, and automatic gain provide intuitive Peak and Null locating. A visual centerline marks the location of your utility (peak). Simultaneously, the highest signal strength and sudden tone silence pinpoint the centerline (null). Automatic gain enhances these features by providing the best possible gain.
Distance Sensitive Left/Right GuidanceTM - Shows Your Path
The LCD centerline guides you to your target conductor. A needle moving to the right (steady tone), guides you to the right. Moving left (pulsing tone), guides you left. A centered needle, high signal-strength, and silent tone positions you directly over your target
VM-810 Receiver Specifications | |
Description | Single High-Frequency Locator Receiver |
Uses | Locating & pinpointing the position of buried pipes and cables |
Construction | - High impact thermoplastic (ABS) injection molded housing - Retractable aluminum antenna tube |
Weight | 3.1lbs (1.4kg) |
Dimensions | Collapsed: 22in(L) x 8.3in(W) x 11in(H) (560mm x 210mm x 280mm) Extended: 31.1in(L) x 8.3in(W) x 11in(H) (790mm x 210mm x 280mm) |
Display Type | Black & white TFT 2.7” LCD WQVGA display (400 x 240 pixel) |
Receiver Antennas | 3 x Peak antennas, 1 x compass antenna |
Batteries | 2 x D-Cell alkaline batteries |
Battery Life | Typically 65 hours continuous use at 70ºF (21ºC) |
Environmental | IP54 and NEMA 4 |
External Connectors | - 1 x 3.5mm Headphone jack - 1 x Mini USB socket for software update - 1 x 4 pin Accessory jack |
Temperature Range | Operating: -4ºF to 122ºF (-20ºC to 50ºC) |
Compliance/Approvals | - Complies with European standard CE (Directive 99/5/EC) • EN 55011 • EN 61000-4-3 • EN 61000-4-2 • EN 61000-4-8 - Complies with FCC Rules Part 15 • CFR 47 Part 15: 2006 |
Information Displayed | - Signal strength : Numeric value - Distance sensitive Left/Right Centerline offset needle indicator - Compass: +/- 90°line direction indicator - Battery indicator - Depth and current reading |
Audio Indication | - Tones for Left or Right - Fading when close to centerline - Silence when centered or signal is too weak |
Configuration | Easy One-button operation: - Automatic backlight control - Short press – On - Long press – Off - Short press when the unit is switched On – Depth and Current reading |
Operating Frequencies | 83.1kHz (83,077.5 Hz) |
Operating Modes | - Peak locate - Sonde |
Gain / Scaling Control | Automatic Gain control |
Performance Using Single Undistorted Signal Source | |
Trace accuracy: | - Distance Sensitive Left/Right GuidanceTM |
Current measurement accuracy: | - 5% of actual current – up to 10ft (3m) - 10% of actual current – up to 20ft (6m) |
Depth measurement accuracy: | - 10 feet (3m): +/-5% or 2” - 20 feet (10m): +/-10% |
Depth range: Dependent on the strength of signal radiating to the locator | |
Compatible with Transmitters | VM-810, 810 classic, 810DX |
VM-810 Transmitter Specifications | |
Description | Pipe & cable locator transmitter |
Uses | Transmitting active signals for the location of buried pipes and cables |
Construction | High impact thermoplastic (ABS) injection molded housing |
Weight | 2.95 lbs (1.34kg) |
Dimension | 14.6in(L) x 4.5in(W) x 3.3in(H) (370mm x 115mm x 85 mm) |
Power Options | Standard battery pack - using 6 x alkaline “D” cells |
Battery Life | At 70ºF (21ºC) - continuous use Output Power Alkaline 1 watt > 60 hours |
Environmental | IP54 and NEMA 4 |
External Connectors | 3-pin XLR connection socket |
Temperature Range | Operating : -4ºF to 122ºF (-20ºC to 50ºC) Storage : -40ºF to 140ºF (-40ºC to 60ºC) |
Compliance and Approvals | - Complies with European standard CE (Directive 99/5/EC) • EN 55011 • EN 61000-4-2 • EN 61000-4-3 • EN 61000-4-8 - Complies with FCC Rules Part 15 • CFR 47 Part 15 |
Location Modes | - Induction mode – applies signal inductively using the internal antenna - Direct connection mode - applies signal directly to the cable by clipping one output lead to the cable, the other to an independent ground - Clamp mode – applies signal using an inductive clamp (toroid) that is placed around the target cable * Modes are selected automatically when accessories are plugged in. * Default mode (no accessories) is induction |
Transmitting Frequency by Mode | - Induction mode / Direct connection mode / Clamp mode: 83.1kHz (83,077.5Hz) |
Transmitting Mode Power output | In accordance with FCC part 15: - 1 watt – in High output level - 1/3 watt – in Low output level |
Maximum Output Voltage | Maximum output voltage = 60V RMS |
Maximum Output Current | Maximum output current = 150mA RMS constant power |
Output Protection | Output protected against accidental connection to up to 240V AC (50/60Hz) |
Audio indication | - Connection quality – variable beep rate sound showing the better signal applied - Low battery warning |
Controls | Use pushbuttons to select: - Power button: On / Off - Output level button: Low / High - Audio button: Off / Low / High |
Compatible Receivers | VM-810, 810DX, 810 classic |