Yokogawa AQ7270 735023 SM Long Haul Fiber OTDR
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- Yokogawa AQ7270 OTDR Mainframe (BC# 31891-L/T*)
- 735023 SM Long Haul OTDR Module:
- SM OTDR Source:
- 1310nm
- 1550nm
- SC Connector For Source
- SM OTDR Source:
- Power Meter:
- 1310nm
- 1490nm
- 1550nm
- 1625nm
- 1350nm
- 735023 SM Long Haul OTDR Module:
- (2) SM SC-SC Fiber Cables
- Battery Pack
- AC Adapter/Charger
- Power Cord
- USB PC Interface Cable
- User Manual On CD-ROM
- Hard Copy User Manual
- Carrying Case w/ Strap
Yokogawa AQ7270 OTDR:
The AQ7270 OTDR condenses the total working time during on-site tests as the time to power up the device, the time taken to make measurements, and the time to analyze and store the measurement results are reduced significantly. The measurement results can easily be transmitted to computers using the USB interface or the Ethernet and the analysis software (optional) helps with preparation of reports on a computer. The fault event display function detects abnormal connection or reflection points and displays them. Of the events detected by the event detection function, abnormal events that cross a specified threshold value are highlighted in the event table and waveform display.
Simply choose the measured wavelength, then press a button.
The AQ7270 automatically sets the optimal measurement conditions, performs measurement, performs event analysis, and saves data. Because you can save to a different file name each time you execute, measurement and accumulation of data is easy.
Prepare multiple wavelengths to measure, then press a button.
Multi Wavelength Measurement is a mode in which multiple specified wavelengths from the same optical port are measured automatically in order. You can also specify to perform analysis or file saving as needed for each measurement.
Simply choose previously set measurement procedures, then press a button.
You can execute up to five saved measurement procedures in order. A batch of measurement procedures can be run directly from the main menu. Measurement and analysis conditions can be read from a file, making it easy to set up the measurement procedures.390633094877
Features:
- World's Shortest Dead Zone*: <0.8m (2.7 ft) Enables multiple close range event detection
- Tests Up to Four Wavelengths: 850/1300/1310/1490/1550/1625/1650nm and more
- Multiple Functions: Optical Monitor, Light Source, Built-in printer, Built-in Dummy Fiber and more
- Large and Bright 8.4ヤ LCD on a lightweight, compact, and solid body
- Less than 10 sec. Power-up Time: Enables users to start testing in just seconds
- One Button Testing: Executes programmed procedure to improve productivity drastically
- A powerful tool for analyzing, reporting, and printing OTDR test data: AQ7932 OTDR Emulation Software
Specifications:
Model |
AQ7270 |
Display |
8.4-inch TFT LCD color display, 640?480 points |
Display horizontal axis |
|
View range, km |
0.5, 1, 2, 5, 10, 20, 50, 100, 200, 300, 400 |
Measurement of distances |
Distance between any two points are displayed at reflectogram as an eight-unit number |
Distance measurement error |
1 m or ムdistanceメ *2*10-5 (the greater one) |
Readout resolution, cm |
1 (minimum) |
Sampling density, m |
0.05, 0.1, 0.2, 0.5, 1, 2, 4, 8, 16, 32 |
Number of points in reflectogram |
Up to 50000 points |
Range of group-refractive index |
1.30000 ナ 1.79999 with a step 0.00001 |
Display vertical axis |
|
Attenuation scale, dB/div. |
0.2; 0.5; 1; 2; 5; 7.5 |
Readout resolution, dB |
0.001 (minimum) |
Loss measurement |
Signal level is displayed a five-unit number in step 0.001 dB. Functions of loss measurement at fiber section, long attenuation, loss at local inhomogeneity |
Return loss measurement |
Functions of local inhomogeneity reflectometry, and measurement of total reflection factor at a line section |
Loss measurement error, dB/dB |
0.05 |
General characteristics |
|
Laser |
Laser of Class 1 ? (standard IEC60825-1:2001) |
Optical pulse length |
3 ns, 10 ns, 20 ns, 50 ns, 100 ns, 200 ns, 500 ns, 1 mcs, 2 mcs, 5 mcs, 10 mcs, 20 mcs |
Optical fiber type |
SM 10/125 (ITU-T G.652) |
Optical connector |
Adapter SC/FC |
Memory |
Not less than 1000 モscan imagesヤ. Measurement results and settings can be saved at an auxiliary memory connected via interface USB 1.1. |
Interfaces |
USB 1.1 type ? ヨ for external memory and printer Ethernet ヨ supports FTP protocol |
Network adapter |
100-240 V, 50/60 Hz, up to 70 W (when printer in use or battery charging); |
Battery |
Type: NiMH. Operation without recharging: about 6 hours (30 sec. of measurement every 10 minutes, in energy-saving mode). Charging duration: less than 5 hours. |
Operation temperature |
from 0 to +45°? (from 0 to +35°? at battery charging) |
Storage temperature |
from -20 to +60°? |
Relative humidity |
Not more than 85% (without condensation) |
Dimensions and weight |
about 287 mm ? 197 mm ? 85 mm (W?H?D), about 2.8 kg |
735023 OTDR Module Specifications:
Applicable Fiber | SMF |
Number of Wavelengths | 2 |
Wavelength | 1310/1550nm |
Dynamic Range | 40/38dB |
For full Yokogawa AQ7270 product specifications, please click here: Yokogawa AQ7270