Yokogawa DL850 Signal Waveform ScopeCorder
Condition: Refurbished / Calibrated
Warranty: 1 Year Warranty
Shipping: USA & Worldwide
- Yokogawa DL850 Signal Waveform ScopeCorder (BC# -L/T*)
- Power Cord
- User Manual On CD-ROM
Yokogawa DL850 Signal Waveform ScopeCorder
The DL850/DL850V ScopeCorders are modular, signal waveform recording instruments that can synchronously measure various signals such as voltage, current, strain, and acceleration. They measure multiple physical signals for a long period at the sites of developing products in the mechatronics area where noise rejection is emphasized. The standard model DL850 and the Vehicle Edition DL850V, which is primarily intended for developing devices used in automobiles, are offered.
A total of 15 plug-in modules are available for measurement.
High speed isolated measurement
Adopting high speed optical fiber-based transmissions (isoPRM TM technology), DL850 is capable of 1 kV high voltage isolation measurement while achieving high-speed data acquisition of 100 MS/s, A/D resolution of 12 bits, analog bandwidth of 20 MHz
High speed waveform display
Adopting the Giga zoom Engine 2 high-speed data processing system applying Yokogawa’s original data processing algorithm, DL850 can quickly display up to 2 G points data in the memory and two zoomed waveforms.
Excellent noise rejection performance
Excellent noise rejection performance (high CMRR of approx. 90 dB at 10 kHz for the 10 MS/s high-speed isolation module) is achieved through exhaustive low-noise design. Even floating voltage switching waveforms of inverter circuits can be precisely captured.
Multi-channel measurement
With maximum 8 modules of the 16-CH voltage input module (scanner type), 128-CH voltages can be measured at 10 kS/s sample rate. One logic input module can measure 16 relay states or sequence states simultaneously, enabling measurement of 128 logic states with eight modules.
Max. Sampling Rate | 100 MS/s |
Frequency Bandwidth |
20 MHz |
Number of input Channels |
max. 128 (8 slots) |
Logic inputs |
max. 128 (720230 model) |
A/D resolution |
16 or 12 bits |
Time axis setting range |
100ns/div to 3 days/div |
Max. recording length |
standard 250 Mpts M1 option - 1 Gpts M2 option - 2 Gpts |
Number of waveforms for between-channel math |
Max. 8 |
Number of waveforms for real time math |
Max. 16 |
Built-in Media drive |
SD memory card slot(standard) 160 GB HDD (option) External HDD I/F (option) |
Communication interface |
USB 2.0(standard) 1000Base-T Ethernet (standard) GP-IB(option) |
Other options |
IRIG interface User defined calculation Probe power output |
Display |
10.4-inch color TFT LCD display |
Dimensions |
355 mm (W) x 259 mm (H) x 180 mm (D) |
Weight |
Approx. 6.5 to 9.0 kg |