Agilent DSO81304B 13GHz Infiniium High Performance Oscilloscope

$23,529.00
Availability: In stock
SKU
11H72

Condition: Refurbished / Calibrated

Warranty: 1 Year Warranty

Agilent Infiniium DSO81304B Oscilloscopes and InfiniiMax

 

With the superior signal integrity, probing and application software selection of Agilent Technologies’ Infiniium 80000B Series and InfiniiMax II probing system will lead to improved measurements and increased design margins.

 

The signal integrity advantages of Agilent’s Infiniium 80000B Series Scopes and InfiniiMax probing system include the industry’s lowest noise floor, lowest jitter measurement floor, lowest trigger jitter and flattest frequency response. These foundational capabilities are crucial for achieving accurate and repeatable measurements. These superior signal integrity capabilities come from Agilent’s RF design experience, proprietary packaging technologies and unique CMOS ADC architecture. Superior signal integrity maximizes your design margins by not wasting any measurement accuracy due to poor noise, jitter or frequency response of the scope or probing system.

 

The probing advantages of the InfiniiMax Series probes include the low noise and flat frequency response mentioned above. The InfiniiMax Series also offers the industry’s widest selection of probe amplifier bandwidths (currently six) and the industry’s widest variety of different probe head types (currently 11 + one extension cable). InfiniiMax is also the probing system that offers 13 GHz bandwidth for the differential solder-in, differential browsing and differential SMA use models. It now supports a unique environmental chamber probe extension solution as well. Since its inception, the awardwinning InfiniiMax probe system has provided maximum performance with unmatched usability.

 

The application software for the Infiniium 80000B Series is the industry’s largest – currently offering a choice of 29 different application packages. Application specific software solutions include compliance test packages for industry standards such as: PCI-Express®, DDR, FBD, SATA, SAS, FC, DVI, HDMI, USB, FireWire, Ethernet, XAUI, Serial Rapid IO, CPRI, OBSAI RP3, and DisplayPort as well as more general purpose jitter and serial data analysis packages. Agilent is also the industry-leading vendor to offer innovative packages for ultra-wideband vector signal analysis, noise reduction and bandwidth control, and InfiniiScan event identification software.

 

The industry-leading signal integrity, probing and software application capabilities of the Infiniium 80000B Series scopes and InfiniiMax Series probes have recently won four industry awards.

 

Superior signal integrity and probing for your application

Agilent doesn’t only deliver industry leading oscilloscope performance. It also uses the company’s extensive technology base to provide superior signal integrity, probing and analysis software for the designer’s specific application. The most notable benefits of the Agilent solution are:

  • Industry’s lowest scope noise floor
  • Industry’s lowest jitter floor
  • Industry’s lowest trigger jitter
  • Industry’s flatest frequency response
  • Industry’s leading hardware sensitivity
  • Industry’s only bandwidth upgradeable series

 

Probing

  • Industry’s lowest probe noise floor
  • Industry’s widest range of probe amplifier bandwidths
  • Industry’s widest range of probe head types
  • Industry’s flatest probe frequency response
  • Industry’s only environmental chamber probing solution supporting temperatures from –55 to +150 °C

 

Applications

  • Industry’s largest set of applications
  • Industry’s only event identification software
  • Industry’s only wideband spectrum analyzer software
  • Industry’s first noise reduction software
  • Industry’s only calibrated jitter measurement
  • Industry’s only compliance test framework to support FibreChannel, DDR1, 2, and 3, XAUI, Serial Rapid IO, CPRI, OBSAI PR3, and DisplayPort
  • Industry’s only application server license solution for the oscilloscopes

Features:

  • 2 GHz to 13 GHz bandwidth with up to 40 GSa/s sample rate
  • Up to 2 Mpts MegaZoom memory at 40 GSa/s sample rates and 64 Mpts MegaZoom deep memory at 4 GSa/s
  • Full bandwidth probe system for all use models – up to 13 GHz bandwidth for differential solder-in, browser and SMA connections
  •  Industry’s lowest noise floor for both oscilloscopes and probes
  • Industry’s lowest jitter measurement floor
  • Industry’s only environmental chamber probing solution supporting temperatures from –55 to +150 °C
  • Industry’s flattest frequency response
  • Industry’s only full bandwidth economical lead-free solder-in probe solution
  • Industry’s only bandwidth– upgradeable series from 2 GHz to 13 GHz
  • Industry’s largest selection of application software packages
  • Industry’s first software event finder “InfiniiScan”
  • Industry’s only server based oscilloscope application software license solution
  • Now LXI class C compliant

 

Specifications:

Model DSO81304B
Real-time bandwidth on 2 channels and 40 GSa/s 13 GHz
Equivalent-time bandwidth on 4 channels 13 GHz
Real-time bandwidth on 4 channels at 20 GSa/s 8 GHz
Vertical
Input channels 4
Analog bandwidth (–3 dB)0 12 GHz
DSP enhanced bandwidth 81304B: 13 GHz real-time, user selectable DSP enhanced-bandwidth
Rise time/fall time 10 - 90%: 32 ps
20 - 80%: 24 ps
Input impedance 50 Ω ± 3%
Sensitivity1 mV/div to 1 V/div
Input coupling DC
Vertical resolution 8 bits, ≥ 12 bits with averaging
Channel-to-channel isolation (any two channels with equal V/div settings) DC to 3 GHz: 60 dB
3 GHz to 8 GHz: 40 dB
8 GHz to BW: 35 dB
DC gain accuracy ± 2% of full scale at full resolution channel scale
Maximum input voltage ± 5 V
Offset range Vertical sensitivity:
0 mV/div to ≤ 40 mV/div
> 40 mV/div to ≤ 75 mV/div
> 75 mV/div to ≤ 130 mV/div
> 130 mV/div to ≤ 240 mV/div
> 240 mV/div
Available offset:
± 0.4 V
± 0.9 V
± 1.6 V
± 3.0 V
± 4.0 V

Offset accuracy ≤ 3.5 V: ± (2% of channel offset + 1% of full scale) +1 mV > 3.5 V: ± (2% of channel offset + 1% of full scale)
Dynamic range ± 4 div from center screen
DC voltage measurement accuracy Dual cursor: ± [(DC gain accuracy)+(resolution)]
Single cursor: ± [(DC gain accuracy)+(offset accuracy)+(resolution/2)]
RMS noise floor (scope only)
Volts/div
5 mV: 419 µV
10 mV: 498 µV
20 mV: 737 µV
50 mV: 1.71 mV
100 mV: 3.34 mV
200 mV: 6.55 mV
500 mV: 17.3 mV
1 V: 33.9 mV
RMS noise floor (scope with probe) 20 mV: 3.0 mV
50 mV: 3.4 mV
100 mV: 4.6 mV
200 mV: 7.8 mV
500 mV: 117 mV
1 V: 34 mV
Horizontal
Main timebase range 5 ps/div to 20 s/div real-time, 5 ps/div to 500 ns/div equivalent-time
Main timebase delay range –200 s to 200 s real-time, –25 µs to 200 s equivalent-time
Delayed timebase range 1 ps/div to current main time scale setting
Channel deskew ± 25 µs range, 100 fs resolution
Time scale accuracy ± 1 ppm pk
Delta-time measurement accuracy
≥ 256 averages, rms
≥ 256 averages, peak
Averaging disabled, rms
Averaging disabled, peak
45 fs rms
500 fs peak
0.9 ps rms
5 ps peak
Jitter measurement floor
Time interval error
Period jitter
N-cycle, cycle-cycle jitter
0.70 ps rms
0.9 ps rms
1.4 ps rms
Acquisition
Maximum real-time sample rate 40 GSa/s (2 channels simultaneously)
20 GSa/s (4 channels simultaneously)
Memory depth per channel Standard: 524,288 (2 channels)     262,144 (4 channels)
Sampling modes Real-time: Successive single-shot acquisitions
Real-time with averaging: Selectable from 2 to 65534
Real-time with peak detect: 2 GSa/s peak detect (4 channels), 4 GSa/s peak detect (2 channels)
Real-time with hi resolution: Real-time boxcar averaging reduces random noise and increases resolution
Resolution: 100 fs Full bandwidth on all 4 channels, 262,144 sample points maximum memory. Acquires channels 1 and 3 simultaneously, followed by channels 2 and 4 simultaneously on subsequent triggers at 40 GSa/s each
Equivalent-time (alternating real-time): Captures bursting signals at maximum sample rate without consuming memory during periods of inactivity. Selectable number of segments up to 16,384 with Option 001 deep memory installed. Minimum intersegment time (the time between the end of the previous acquisition and the beginning of the next acquisition) of 20 µs. See the table below for various performance points.
Sample rate Maximum number of segments 4-channel mode
40 GSa/s: N/A
20 GSa/s: 64
5 GSa/s - 64
≤ 4 GSa/s: 128

2-channel mode
40 GSa/s: 128
20 GSa/s: 128
5 GSa/s - 128
≤ 4 GSa/s: 256
Sample rate Maximum trigger rate Sample rate 1 k pts
40 GSa/s: 33 kHz
20 GSa/s: 41 kHz
5 GSa/s - 47 kHz
4 GSa/s: 50 kHz
2 GSa/s: 50 kHz

10 k pts
40 GSa/s: 22 kHz
20 GSa/s: 24 kHz
5 GSa/s: 25 kHz
4 GSa/s: 45 kHz
2 GSa/s: 43 kHz
Filters Sin(x)/x Interpolation:
On/off selectable FIR digital filter. Digital signal processing adds points between acquired data points to enhance measurement accuracy and waveform display quality
Hardware trigger
Sensitivity Internal low: 2.0 div p-p 0 to 5 GHz
Internal high: 0.3 div p-p 0 to 4 GHz, 1.0 div p-p 4 to 7.5 GHz
Auxiliary: DC to 1 GHz: 200 mV p-p into 50 Ω
Level range Internal: ± 4 div from center screen or ± 4 Volts, whichever is smallest
Auxiliary: ± 5 V, also limit input signal to ± 5 V
Sweep modes Auto, triggered, single
Trigger jitter ≤ 500 fs rms for 8-GHz to 13-GHz models
≤ 1 ps rms for 2-GHz to 6-GHz models
Trigger holdoff range 100 ns to 10 s
Trigger actions Specify an action to occur and the frequency of the action when a trigger condition occurs. Actions include e-mail on trigger and QuickMeas+.
Trigger modes Edge: Triggers on a specified slope (rising, falling or alternating between rising and falling) and voltage level on any channel or auxiliary trigger.
Glitch: Triggers on glitches narrower than the other pulses in your waveform by specifying a width less than your narrowest pulse and a polarity. Triggers on glitches as narrow as 500 ps. Glitch range settings: < 1.5 ns to < 10 s. Line Triggers on the line voltage powering the oscilloscope
Pattern / pulse range: Triggers when a specified logical combination of the channels is entered, exited, present for a specified period of time or is within a specified time range. Each channel can have a value of high (H), low (L) or don’t care (X). Triggers on patterns as narrow as 500 ps.
State: Pattern trigger clocked by the rising or falling edge or alternating between rising and falling edge of one channel
Delay by time: The trigger is qualified by an edge. After a specified time delay between 5 ns to 10 s, a rising or falling edge on any one selected input will generate the trigger.
Delay by events: The trigger is qualified by an edge. After a specified delay between 1 to 16,000,000 rising or falling edges, another rising or falling edge on any one selected input will generate the trigger.
Trigger shortcuts Provides easy shortcuts to all trigger features
Violation triggers Pulse width: Trigger on a pulse that is wider or narrower than the other pulses in your waveform by specifying a pulse width and a polarity. Triggers on pulse widths as narrow as 500 ps. Pulse width range settings: 1.5 ns to 10 s.
Setup/hold: Triggers on setup, hold or setup and hold violations in your circuit. Requires a clock and data signal on any two input channels as trigger sources. High and low thresholds and setup and/or hold time must then be specified.
Transition: Trigger on pulse rising or falling edges that do not cross two voltage levels in > or < the amount of time specified.
Measurements and math
Waveform measurements Voltage: Peak to peak, minimum, maximum, average, RMS, amplitude, base, top, overshoot, preshoot, upper, middle, lower
Time: Rise time, fall time, period, frequency, positive width, negative width, duty cycle, burst width, Tmin, Tmax, setup time (requires Option 002 or 004), hold time (requires Option 002 or 004), delta time, channel-to-channel phase
Mixed: Area, slew rate
Frequency domain: FFT frequency, FFT magnitude, FFT delta frequency, FFT delta magnitude
Level qualification: Any channels that are not involved in a measurement can be used to level qualify all timing measurements.
Statistics Displays the mean, standard deviation, minimum, maximum and number of measurements value for the displayed automatic measurements
Histograms Vertical (for timing and jitter measurements) or horizontal (noise and amplitude change) modes, regions are defined using waveform markers. Measurements included: mean, standard deviation, peak-to-peak value, median, min, max, total hits, peak (area of most hits), and mean ± 1, 2, and 3 sigma.
Eye-diagram measurements Eye height, eye width, eye jitter, crossing percentage, Q factor, and duty-cycle distortion
Jitter analysis measurements
(E2681A EZJIT or N5400A EZJIT Plus jitter analysis software)
Cycle-cycle jitter, N-cycle jitter, cycle-cycle + width, cycle-cycle – width, cycle-cycle duty cycle, data rate, unit interval, time interval error data, time interval error clock, setup time, hold time, phase, period, frequency, + width, – width, duty cycle, rise time, fall time
Mask testing Allows pass/fail testing to user-defined or Agilent-supplied waveform templates. AutoMask lets you create a mask template from a captured waveform and define a tolerance range in time/voltage or percentage. Test modes include test forever, test to specified time or event limit, and stop on failure. Communications mask test kit option provides a set of ITU-T G.703, ANSI T1.102, and IEEE 802.3 industry-standard masks for compliance testing.
Waveform math Four functions, select from absolute value, add, average, common mode, differentiate, divide, FFT magnitude, FFT phase, high-pass filter, integrate, invert, low-pass filter (4th order Bessel Thompson Filter), magnify, max, min, multiply, smoothing, square, square root, subtract, versus, and optional user-defined function (Option 010)
FFT Frequency range:  DC up to 20 GHz (at 40 GSa/s) or 10 GHz (at 20 GSa/s)
Frequency resolution: Sample rate/memory depth = Resolution
Best resolution at maximum sample rate: 20 kHz
Frequency accuracy: (1/2 frequency resolution)+(1 x 10-6)(signal frequency)
Signal-to-noise ratio: 60 dB to > 100 dB depending on settings
Window modes: Hanning, flat-top, rectangular
Measurement modes Automatic measurements: Measure menu access to all measurements, five measurements can be displayed simultaneously
QuickMeas+: Front-panel button activates five preselected or five user-defined automatic measurements
Drag-and-drop measurement toolbar: Measurement toolbar with common measurement icons that can be dragged and dropped onto the displayed waveforms
Marker modes Manual markers, track waveform data, track measurements
Display
Display Display: 8.4-inch color (21.34 cm) XGA TFT-LCD with touch screen
Intensity grayscale: 256-level intensity-graded display
Resolution: XGA: 1024 pixels horizontally x 768 pixels vertically
Annotation: Up to 12 labels, with up to 100 characters each, can be inserted into the waveform area
Grids: Can display 1, 2 or 4 waveform grids
Waveform styles: Connected dots, dots, infinite persistence, color-graded infinite persistence. Includes up to 256 levels of intensity-graded waveforms.
Waveform update rate Fastest: 4,800 waveforms/sec (memory depth: 64 pts, sampling: 10 GS/s, time/div: 50 ps, connect dots: off, Sin (x)/x: off, color grade: off)
Nominal: 800 waveforms/sec (memory depth: 1000 pts, sampling: 40 GS/s, time/div: 500 ps, connect dots: on, Sin (x)/x: on, color grade: off)
Computer system and peripherals, I/O ports
Computer system and peripherals Operating System: Windows XP Pro
CPU: Intel® Celeron 3.2-GHz microprocessor
PC: system memory 1-GB DDR2
Drives: ≥ 40-Gb internal hard drive (optional removable hard drive), CD-ROM drive on rear panel
Peripherals: Logitech optical USB mouse, compact keyboard and stylus supplied. All Infiniium models support any Windows-compatible input device with a serial, PS/2 or USB interface
File types Waveforms: Compressed internal format (*.wfm), comma-separated values (*.csv), tab-separated values (*.tsv) and Y value files (*.txt)
Images: BMP, PCX, TIFF, GIF or JPEG
I/O ports LAN: RJ-45 connector, supports 10Base-T, 100Base-T, and 1000Base-T. Enables Web-enabled remote control, e-mail on trigger or demand, data/file transfers and network printing.
GPIB: IEEE 488.2, fully programmable
RS-232 (serial): COM1, printer and pointing device support
Parallel: Centronics printer port PS/2 Two ports. Supports
PS/2: pointing and input devices. USB 2.0 Hi-Speed One port on front panel plus four ports on rear panel. All
USB 2.0: High-speed compatible.
Allows connection of USB peripherals like storage devices and pointing devices while the oscilloscope is on.
Dual-monitor video output: 15-pin XGA, full color output of scope waveform display or dual monitor video output (up to SXGA resolution with a dual monitor use)
Auxiliary output: DC (± 2.4 V); square wave (~715 Hz and 456 MHz); trigger output (255 mV p-p into 50 Ω)
Trigger output: 5 V 50 Ω back-terminated
Time base reference output: 10-MHz filtered sine wave with all harmonics ≤ –40 dBc. Amplitude into 50 Ω: 800 mV p-p to 1.26 V p-p (4 dBm ± 2 dB) if derived from internal reference. Tracks external reference input amplitude ± 1 dB if applied and selected.
Time base reference input: Must be 10 MHz, input Z0 = 50 Ω. Minimum 360 mV p-p (–5 dBm), maximum 2.0 V p-p (+10 dBm)
LXI compliance Functional Class C
General characteristics
Temperature Operating: 5 °C to +40 °C
Non-operating: –40 °C to +70 °C
Humidity Operating: Up to 95% relative humidity (non-condensing) at +40°C
Non-operating: Up to 90% relative humidity at +65°C
Altitude Operating: Up to 4,600 meters (15,000 feet)
Non-operating: Up to 15,300 meters (50,000 feet)
Vibration Operating: Random vibration 5-500 Hz, 10 minutes per axis, 0.3 g(rms)
Non-operating: Random vibration 5-500 Hz, 10 minutes per axis, 2.41 g(rms); resonant search 5-500 Hz, swept sine, 1 octave/minute sweep rate, (0.75g), 5-minute resonant dwell at 4 resonances per axis
Power 100 - 240 VAC at 50/60 Hz; maximum input power 550 Watts
Weight Net: 13 kg (28.5 lbs.) Shipping: 16 kg (35.2 lbs.)
Dimensions (excluding handle) Height: 216 mm (8.5 in)
Width: 437 mm (17.19 in)
Depth: 440 mm (17.34 in)
Safety Meets IEC 61010-1 +A2, CSA certified to C22.2 No.1010.1, self-certified to UL 3111
For full Agilent DSO81304B High Performance Oscilloscope product specifications, please click here: Agilent DSO81304B

Agilent DSO81304B 13GHz Infiniium High Performance Oscilloscope

The signal integrity advantages of Agilent’s Infiniium 80000B Series Scopes and InfiniiMax probing system include the industry’s lowest noise floor, lowest jitter measurement floor, lowest trigger jitter and flattest frequency response

Includes Accessories As Listed

BC# -L/T*

 

  • Agilent DSO81304B 13GHz Infiniium High Performance Oscilloscope (BC# -L/T*)
  • USB PC Interface Cable
  • User Manual On CD-ROM
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!