Keysight Agilent N1077A DCA-M Electrical Optical Clock Recovery w/ Opts 232/SMS

$25,509.00
Availability: In stock
SKU
11H92

Condition: Refurbished/Calibrated

Warranty: 1 Year Warranty

Keysight N1077A DCA-M Electrical and Optical Clock Recovery


Electrical and Optical Clock Recovery Solutions

Keysight clock recovery solutions offer a wide data rate range and are ideal for many
transmitter and receiver test setups for computers, datacom, and communication
standards.

The Keysight Technologies, Inc. electrical clock recovery solutions provide clock recovery
capabilities for electrical non-return-to-zero (NRZ) and pulse amplitude modulation
4-level (PAM4) signals.

The Keysight Technologies, Inc. optical/electrical clock recovery integrates electrical
clock recovery with an amplified optical-to-electrical (O/E) converter, enabling it to
work for both electrical and optical applications. Optional integrated optical splitters are
available, which simplifies setup and improves ease-of-use.

All models include adjustable loop bandwidth and selectable peaking, and provide
high sensitivity and low intrinsic jitter performance that ensures optimal measurement
accuracy. The optional jitter spectrum analysis (JSA) capability provides insight into the
magnitude and distribution of low-frequency jitter, which is helpful in troubleshooting
root cause for excessive jitter.



Key Features and Functions

  • 50 MBaud to 32 GBaud data rate range (continuous) on optical and electrical designs
  • Provides standards-compliant clock recovery (CR) for NRZ and PAM-4 data signals
  • Yields flexible, compact, high-sensitivity CR design with an integrated amplified optical-to-electrical (O/E) converter
  • Gain optimal ease-of-use with integrated splitter and bulk optics coupler (Option SMS)

 

Electrical Data Input (+/–)
Data rate input range 50 MBd to 32 GBd
Minimum input level to acquire lock 30 mVpp (for rates ≤ 27 GBd)
35 mVpp (for rates > 27 GBd)
Input voltage levels (min/max) ± 2.2 Vpp (maximum)
Minimum transition density 20%
Interface Differential or single-ended, AC coupled, 50 Ω
Connector type 2.92 mm (f)
Recovered Clock Output Description
Clock output range 50 MHz to 16 GHz
Recovered clock random jitter 220 fs max at ≥ 2 Gbd
Loop Bandwidth Range (user selectable) 0.015 to 20 MHz
Loop bandwidth accuracy ± 30% (characteristic
Clock recovery peaking range Up to 4 settings (dependent on loop BW)
Tracking Range (includes spread-spectrum tracking) ± 2500 ppm ± 0.25% (characteristic)
Acquisition range ± 5000 ppm (characteristic)
Auto relocking Yes
Residual spread spectrum –84 dB ± 3 dB at 33 kHz (characteristic
Phase noise accuracy 30% (characteristic)
Front panel recovered clock amplitude ≥ 320 mVpp at 5 GHz
Front Panel Recovered Clock Divide Ratio (user selectable) 1, 2, 4, 8, 16
Internal frequency counter accuracy ± 10 ppm
Interface Single-ended, AC coupled, 50 Ω
Connector type 2.92 mm (f)
Aux Clock Output
Output frequency 4 GHz to 8 GHz
Output voltage 550 mVpp (characteristic)
Output jitter < 50 fs RMS (characteristic)
Interface Single-ended, DC coupled, 50 Ω
Connector type 2.92 mm (f)
Environmental Specifications
Use Indoor
Temperature Operating
Temperature Non-operating
10C to +40C (50°F to +104°F)
−40C to +70C (−40°F to +158°F)
Altitude (Operating) Up to 4,600 meters (15,000 ft)
Maximum Relative Humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C
Line Power 100/120Vac, 50/60/400 Hz
220/240Vac, 50/60 Hz
290 Watts Maximum
The products can operate with mains supply voltage fluctuations up to ±10% of the nominal voltage.
Volts-Amperes (VA) 52 VA (characteristic)
Weight 6.3 kg (13.8 lb) (characteristic)

 

For full Agilent N1077A Electrical Optical Clock Recovery product specifications, please click here: N1077A

Keysight N1077A DCA-M Electrical and Optical Clock Recovery

Installed Options:
- Option 232: Supported input rates: 50 MBaud to 32 GBd  
- Option SMS: Internal single-mode (9/125 µm) and multimode (50/125 µm) splitter

Includes Accessories As Listed Above!

  • Keysight N1077A DCA-M Electrical and Optical Clock Recovery w/ Options: (BC# -L/T*)
    • Option 232: Supported input rates: 50 MBaud to 32 GBd
    • Option SMS: Internal single-mode (9/125 µm) and multimode (50/125 µm) splitter
  • Power Cord
  • User Manual on CD
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!