Anritsu S331P SiteMaster Ultraportable Cable and Antenna Analyzer
$2,689.00
Availability:
Out of stock
SKU
6C212
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
Request a Quote for
- Anritsu SiteMaster S331P Cable & Antenna Analyzer (BC# -L/T*)
- USB PC Interface Cable
- Carrying Case
Anritsu S331P SiteMaster Ultraportable Cable and Antenna Analyzer
Anritsu introduces its ninth generation, compact handheld Cable & Antenna Analyzer for installation and maintenance of antenna systems. It is available in two frequency ranges starting from 150 kHz and up to 4 GHz or 6 GHz. The S331P is now also supported by the Field Master Pro™ MS2090A with Option 331.
Features:
- Impact, Dust, and Splash Resistant
- Smallest, Lightest, and Fastest Site Master
- EZ Name Quick Matrix
- Fast Preview of Stored Sweeps
- Compatible with HHST
Specifications:
| Measurements | VSWR Return Loss Cable Loss (One Port) Distance-to-Fault (DTF) Return Loss Distance-to-Fault (DTF) VSWR Smith Chart 50/75 (Advanced Mode Only) 1-Port Phase (Advanced Mode Only) Transmission with External Sensor (Advanced Mode Only) |
| Setup Parameters - Classic | Measurement: Display Single Display with independent markers Frequency: Start Frequency (F1), Stop Frequency (F2) DTF: Start Distance (D1), Stop Distance (D2), DTF Aid, Cable Loss, Propagation Velocity, Cable type Windowing: Rectangular, Normal Side Lobe, Low Side Lobe, Minimum Side Lobe Amplitude: Top, Bottom Auto Scale, Full Scale Sweep: Data Points, Run/Hold, Single/Continuous, Trace Data Points: 130, 259, 517, 1033, 2065 Markers: Markers 1 to 6 (On/Off), Delta Markers 2 to 4 (Ref M1), Marker to Peak/Valley, Marker Table, Marker 5 (Peak/Valley between M1 & M2), Marker 6 (Peak/Valley between M3 & M4), Independent Markers for Frequency and Distance Measurements Traces: Copy Trace To Memory, Trace Display, Trace Math [Trace - Memory, Trace + Memory, (Trace + Memory)/2] Limit Line: On/Off, Edit Value, Limit Alarm, Pass/Fail On/Off, Limit Preset Calibration: Factory default 1-Port ReadyCal (automatically applied to all measurements) User calibration (User Cal) overrides ReadyCal Start Calibration, Cal Info, User Cal (On/Off), Cal Method: OSL Cal Types: Standard, FlexCal™ Save/Recall: Setups, Measurements, Screenshots |
| Setup Parameters - Advanced | Measurement Display: Single/Dual Display with independent markers Frequency: Start Frequency (F1), Stop Frequency (F2) DTF: Start Distance (D1), Stop Distance (D2), Units m/ft, DTF Aid, Cable List, Cable Loss, Propagation Velocity Windowing: Rectangular, Normal Side Lobe, Low Side Lobe, Minimum Side Lobe Amplitude: Top, Bottom, Auto Scale, Full Scale Sweep: Data Points, Run/Hold, Single/Continuous, RF Immunity (High/Low) Data Points: 130, 259, 517, 1033, 2065 Markers: Markers 1 to 8 (On/Off), Delta Markers 2 to 8 (Ref M1), Marker Tracking (On/Off), Marker to Peak/Valley, Marker Table, Marker 5 & 7 (Peak/Valley between M1 & M2), Marker 6 & 8 (Peak/Valley between M3 & M4), Independent Markers for Frequency and Distance Measurements Traces: Copy Trace to Memory, Trace Display, Trace Math [Trace - Memory, Trace + Memory, (Trace + Memory)/2] Limit Line: Active Limit (Upper/Lower), Limit State (On/Off), Move Active Limit, Edit Segments (42 upper and 42 lower segments maximum), Limit Alarm, Pass/Fail On/Off, Limit Preset Calibration: Factory default 1-Port ReadyCal (automatically applied to all measurements except Transmission) User calibration (User Cal) overrides ReadyCal Start Calibration, Cal Info, User Cal (On/Off), Cal Methods: OSL, Transmission, OSL + Transmission Cal Types: Standard, FlexCal™ Save/Recall: Setups, Measurements, Screen Shots |
| Frequency | Frequency Ranges: 150 kHz to 4 GHz (S331P-0704) 150 kHz to 6 GHz (S331P-0706) Frequency Accuracy: ± 2.5 ppm @ 23 °C ± 3 °C Frequency Resolution: 1 kHz |
| Power | Output Power –5 dBm, typical |
| Interference Immunity | On Channel and On Frequency +17 dBm, typical |
| Measurement Speed | 500 µs/data point (timing dependent on external computer configuration) |
| Return Loss | Measurement Range: 0 to 60 dB Resolution: 0.01 dB |
| VSWR | Measurement Range: 1 to 65 Resolution: 0.01 |
| Cable Loss | Measurement Range: 0 to 30 dB Resolution: 0.01 dB |
| Distance-to-Fault | Vertical Range Return Loss: 0 to 60 dB Vertical Range VSWR: 1 to 65 Fault Resolution (meters): (1.5 x 108 x vp)/ΔF (vp = propagation velocity, ΔF is F2 – F1 in Hz) Horizontal Range (meters): 0 to (Data Points – 1) x Fault Resolution, to maximum of 1500 meters (4921 ft) |
| 1-Port Phase (Advanced Only) | Measurement Display Range: –450 ° to +450 ° Resolution: 0.01 ° |
| Smith Chart | Impedance: 50 Ω, 75 Ω Resolution: 0.01 |
| Transmission Ext Sensor | Measurement Display Range: –100 dB to +100 dB Resolution: 0.01 dB |
| Measurement Accuracy | Corrected Directivity: ≥ 42 dB, OSL calibration (OSLN50A-8, OSLNF50A-8) |
| GENERAL | |
| Setup Parameters (PC Application) | System Info Status System Setups Language, Display/Audio Language English, French, German, Italian, Spanish, Russian, Portuguese, Japanese, Korean, Chinese Display/Audio Brightness, Color Schemes, Screen Shot Settings, Volume Connectivity USB Diagnostics Self Test Preset Preset, Reset Reset Factory Reset, Delete All User Files, Delete Custom Files, Master Reset File Save, Recall, File Management Save Measurement (*.dat, *.csv), Setup (*.stp), Screen Shot (*.png), System and Self Test Info (*.txt) Recall Recall, Create Folder, Copy, Paste, Delete File Management Rename, Create Folder, Copy, Paste, Delete Navigation Top, Bottom, Page Up, Page Down Help Menu System Info, FAQ, User Guide Internal Trace/Setup Memory > 1000 files for traces, setups, screen shots, or any combination (limited by PC/Tablet storage) External Trace/Setup Memory Limited only by size of USB Flash drive |
| Connectors | RF Port: Type N(m), 50 Ω, Maximum input +23 dBm maximum, ±50 VDC maximum USB Port: USB 2.0 port for connecting to an external PC controller |
| Regulator Compliance | European Union EMC 2014/30/EU, EN 61326:2013, CISPR 11/EN 55011, IEC/EN 61000-4-2/3/4/5/6/8/11 Low Voltage Directive 2014/35/EU Safety EN 61010-1:2010 RoHS Directive 2011/65/EU applies to instruments with CE marking placed on the market after July 22, 2017 Australia and New Zealand RCM AS/NZS 4417:2012 South Korea KCC-REM-A21-0004 |
| Environmental | Operating Temperature Range –10 ºC to 55 ºC Storage Temperature Range –51 ºC to 71 ºC Maximum Relative Humidity 95 % RH at 30 ºC, non-condensing Vibration, Sinusoidal 5 Hz to 55 Hz Vibration, Random 10 Hz to 500 Hz Half Sine Shock 30 gn Altitude 4600 meters, operating and non-operating |
| Size and weight | Size 52 mm x 148 mm x 36 mm (2 in x 5.8 in x 1.4 in) Weight < 0.4 kg (< 0.9 lb), typical |