Anritsu S331P SiteMaster Ultraportable Cable and Antenna Analyzer

Anritsu introduces its ninth generation, compact handheld Cable & Antenna Analyzer for installation and maintenance of antenna systems. It is available in two frequency ranges starting from 150 kHz and up to 4 GHz or 6 GHz. The S331P is now also supported by the Field Master Pro™ MS2090A with Option 331.

 

Features:

  • Impact, Dust, and Splash Resistant
  • Smallest, Lightest, and Fastest Site Master
  • EZ Name Quick Matrix
  • Fast Preview of Stored Sweeps
  • Compatible with HHST

 

Specifications:

Measurements VSWR
Return Loss
Cable Loss (One Port)
Distance-to-Fault (DTF)
Return Loss Distance-to-Fault (DTF)
VSWR Smith Chart 50/75 (Advanced Mode Only)
1-Port Phase (Advanced Mode Only)
Transmission with External Sensor (Advanced Mode Only)
Setup Parameters - Classic Measurement: Display Single Display with independent markers
Frequency: Start Frequency (F1), Stop Frequency (F2)
DTF: Start Distance (D1), Stop Distance (D2), DTF Aid, Cable Loss, Propagation Velocity, Cable type
Windowing: Rectangular, Normal Side Lobe, Low Side Lobe, Minimum Side Lobe
Amplitude: Top, Bottom Auto Scale, Full Scale
Sweep: Data Points, Run/Hold, Single/Continuous, Trace
Data Points: 130, 259, 517, 1033, 2065
Markers: Markers 1 to 6 (On/Off), Delta Markers 2 to 4 (Ref M1), Marker to Peak/Valley, Marker Table, Marker 5 (Peak/Valley between M1 & M2), Marker 6 (Peak/Valley between M3 & M4), Independent Markers for Frequency and Distance Measurements
Traces: Copy Trace To Memory, Trace Display, Trace Math [Trace - Memory, Trace + Memory, (Trace + Memory)/2]
Limit Line: On/Off, Edit Value, Limit Alarm, Pass/Fail On/Off, Limit Preset
Calibration: Factory default 1-Port ReadyCal (automatically applied to all measurements) User calibration (User Cal) overrides ReadyCal Start Calibration, Cal Info, User Cal (On/Off), Cal Method: OSL Cal Types: Standard, FlexCal™
Save/Recall: Setups, Measurements, Screenshots
Setup Parameters - Advanced Measurement Display: Single/Dual Display with independent markers
Frequency: Start Frequency (F1), Stop Frequency (F2)
DTF: Start Distance (D1), Stop Distance (D2), Units m/ft, DTF Aid, Cable List, Cable Loss, Propagation Velocity
Windowing: Rectangular, Normal Side Lobe, Low Side Lobe, Minimum Side Lobe
Amplitude: Top, Bottom, Auto Scale, Full Scale
Sweep: Data Points, Run/Hold, Single/Continuous, RF Immunity (High/Low)
Data Points: 130, 259, 517, 1033, 2065
Markers: Markers 1 to 8 (On/Off), Delta Markers 2 to 8 (Ref M1), Marker Tracking (On/Off), Marker to Peak/Valley, Marker Table, Marker 5 & 7 (Peak/Valley between M1 & M2), Marker 6 & 8 (Peak/Valley between M3 & M4), Independent Markers for Frequency and Distance Measurements
Traces: Copy Trace to Memory, Trace Display, Trace Math [Trace - Memory, Trace + Memory, (Trace + Memory)/2]
Limit Line: Active Limit (Upper/Lower), Limit State (On/Off), Move Active Limit, Edit Segments (42 upper and 42 lower segments maximum), Limit Alarm, Pass/Fail On/Off, Limit Preset
Calibration: Factory default 1-Port ReadyCal (automatically applied to all measurements except Transmission) User calibration (User Cal) overrides ReadyCal Start Calibration, Cal Info, User Cal (On/Off), Cal Methods: OSL, Transmission, OSL + Transmission Cal Types: Standard, FlexCal™
Save/Recall: Setups, Measurements, Screen Shots
Frequency Frequency Ranges: 150 kHz to 4 GHz (S331P-0704) 150 kHz to 6 GHz (S331P-0706)
Frequency Accuracy: ± 2.5 ppm @ 23 °C ± 3 °C
Frequency Resolution: 1 kHz
Power Output Power –5 dBm, typical
Interference Immunity On Channel and On Frequency +17 dBm, typical
Measurement Speed 500 µs/data point (timing dependent on external computer configuration)
Return Loss Measurement Range: 0 to 60 dB
Resolution: 0.01 dB
VSWR Measurement Range: 1 to 65
Resolution: 0.01
Cable Loss Measurement Range: 0 to 30 dB
Resolution: 0.01 dB
Distance-to-Fault Vertical Range Return Loss: 0 to 60 dB
Vertical Range VSWR: 1 to 65
Fault Resolution (meters): (1.5 x 108 x vp)/ΔF (vp = propagation velocity, ΔF is F2 – F1 in Hz)
Horizontal Range (meters): 0 to (Data Points – 1) x Fault Resolution, to maximum of 1500 meters (4921 ft)
1-Port Phase (Advanced Only) Measurement Display Range: –450 ° to +450 °
Resolution: 0.01 °
Smith Chart Impedance: 50 Ω, 75 Ω
Resolution: 0.01
Transmission Ext Sensor Measurement Display Range: –100 dB to +100 dB
Resolution: 0.01 dB
Measurement Accuracy Corrected Directivity: ≥ 42 dB, OSL calibration (OSLN50A-8, OSLNF50A-8)
GENERAL
Setup Parameters (PC Application) System Info Status
System Setups Language, Display/Audio
Language English, French, German, Italian, Spanish, Russian, Portuguese, Japanese, Korean, Chinese
Display/Audio Brightness, Color Schemes, Screen Shot Settings, Volume
Connectivity USB
Diagnostics Self Test
Preset Preset, Reset
Reset Factory Reset, Delete All User Files, Delete Custom Files, Master Reset
File Save, Recall, File Management
Save Measurement (*.dat, *.csv), Setup (*.stp), Screen Shot (*.png), System and Self Test Info (*.txt)
Recall Recall, Create Folder, Copy, Paste, Delete
File Management Rename, Create Folder, Copy, Paste, Delete
Navigation Top, Bottom, Page Up, Page Down Help
Menu System Info, FAQ, User Guide
Internal Trace/Setup Memory > 1000 files for traces, setups, screen shots, or any combination (limited by PC/Tablet storage)
External Trace/Setup Memory Limited only by size of USB Flash drive
Connectors RF Port: Type N(m), 50 Ω, Maximum input +23 dBm maximum, ±50 VDC maximum
USB Port: USB 2.0 port for connecting to an external PC controller
Regulator Compliance European Union EMC 2014/30/EU, EN 61326:2013, CISPR 11/EN 55011, IEC/EN 61000-4-2/3/4/5/6/8/11 Low Voltage Directive 2014/35/EU Safety EN 61010-1:2010 RoHS Directive 2011/65/EU applies to instruments with CE marking placed on the market after July 22, 2017
Australia and New Zealand RCM AS/NZS 4417:2012
South Korea KCC-REM-A21-0004
Environmental Operating Temperature Range –10 ºC to 55 ºC
Storage Temperature Range –51 ºC to 71 ºC
Maximum Relative Humidity 95 % RH at 30 ºC, non-condensing
Vibration, Sinusoidal 5 Hz to 55 Hz
Vibration, Random 10 Hz to 500 Hz
Half Sine Shock 30 gn
Altitude 4600 meters, operating and non-operating
Size and weight Size 52 mm x 148 mm x 36 mm (2 in x 5.8 in x 1.4 in) Weight < 0.4 kg (< 0.9 lb), typical