BK Precision 2650 kit with accessories

BK Precision 2650 Handheld Spectrum Analyzer

BK Precision 2658A kit with accessories

BK Precision 2658A Handheld Spectrum Analyzer

BK Precision 2650A Handheld Spectrum Analyzer

$4,995.00
Availability: In stock
SKU
9S23

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

BK Precision 2650A Handheld Spectrum Analyzer

Truely portable solution for quick and precise spectrum analysis
B&K Precisionメs 2650A series handheld spectrum analyzers are compact, light weight, and cost-effective spectrum analyzers for quick and precise signal investigations, especially away from the bench. At a weight of only 1.8 kg  (4 pounds), the 2650A series are by far the lightest full-featured spectrum analyzer  available, yet they deliver performance and  features comparable to full-size bench spectrum analyzers and can operate up to 4 hours on a single battery

With their ease of use, measurement flexibility, and unmatched portability, the 2650A series analyzers are indispensible tools for engineers and technicians who conduct field measurements in the 50 kHz to 3.5 GHz range.

Applications:

  • Installation, maintenance, and troubleshooting of wireless communication systems such as W-CDMA/CDMA, GSM, WLAN, WiMAX and Bluetooth
  • Detection of signal interference and undesired emissions
  • TV and broadcasting
  • Antenna alignment

Superb performance improves your productivity
Advanced synthesizer-based design enables the 2650A series to provide you with an accurate and detailed picture of the spectrum you are investigating

  • Fast sweep speed, minimum 10 ms, to help locate and identify elusive, transient interference signals
  • DANL (displayed average noise level) of -127 dBm
  • Single sideband phase noise ヨ 90 dBc @ 100 kHz offset


Key features and benefits

  • Frequency range from 50 kHz ヨ 3.3 GHz
  • A truly portable spectrum analyzer weighing only 1.8 kg including the battery
  • Impressive 4 hour battery life; easy-to-replace rechargeable Lithium-Ion battery
  • USB interface for PC connectivity
  • Intuitive PC Software for remote control and documentation of measurement results
  • Conveniently store measurement results and screen shots in bitmap format to USB flash drive (USB host interface)
  • Large easy-to-read color display (TFT LCD), 640 x 480 resolution
  • Measurement functions: channel/adjacent channel power, occupied bandwidth, electric and magnetic field strength 
  • Convenient Auto Tune function automatically sets center frequency to the maximum signal within full span and optimum settings for RBW, VWB and sweep time
  • External trigger for zero span measurements
  • SCPI-like remote control commands

Channel power measurement
Allows you to measure the total power or noise power in a user-specified bandwidth.

Adjacent channel power
Measure the ratio of power leakage (from the wanted signal) into adjacent channels. Center frequency, adjacent channel bandwidth, and offset between main carrier and adjacent channels can be set
Users can select from any of the following three measurement methods based on the reference carrier definition: total power (of displayed spectrum), peak power (reference level) and in-band
power (user-specified band width).

Occupied Bandwidth
This measurement calculates the bandwidth  containing the total integrated power occupied in a given signal bandwidth. Two measurement  methods are available: The user can specify N% of total power or the X dB down point relative to the carrier peak level.


Specifications:

 
Frequency range 50 kHz to 3.3 GHz
Center frequency
Setting
resolution
20 kHz
Settable with rotary encoder, numeric or function key
Accuracy within ± (30+20T) kHz±1 dot
@frequency span: 200 kHz to 10 MHz, RBW 3 kHz, 23±5°C
within ± (60+300T) kHz±1dot
@frequency span: 20 MHz to max. frequency (3.3 GHz), RBW 100 kHz,
23±5 °C
T: sweep time (s)
RBW frequency error  within ±4 kHz @ 3 kHz, 10 kHz, 30 kHz
within 20% of RBW @ RBW: 100 kHz, 300 kHz
within 10% of RBW @ RBW: 1 MHz, 3 MHz
Frequency span
Range 0 Hz (zero span),
200 kHz to 2 GHz (1-2-5 step) and
3.3 GHz (full span)
Accuracy within ±3% ±1dot @ sweep time of 0.3s, 23±5 °C
Display resolution
# of points per trace
501dots on LCD screen, 1001dots readout via PC
(501 dots are visible on the display, 1001 dots of trace data are captured internally
and can be transferred to a PC via USB device interface.)
Resolution bandwidth 3 dB bandwidth
Range 3 kHz to 3 MHz (1-3 sequence) and AUTO
Accuracy ±20%
Shape Factor 1:12 (typical, 3 dB : 60 dB)
Video bandwidth 100 Hz to 1 MHz (1-3 step) and AUTO
SSB phase noise 90 dBc/Hz (typical) @100 kHz offset, RBW : 3 kHz, VBW : 100 Hz, sweep time: 1 s
Spurious response less than -60 dBc
Harmonics less than -40 dBc @ = 100 MHz
Amplitude section
Reference level
Range +10 to -60 dBm (1dB step)
Accuracy within ± 0.8 dB ± 1 dot @ center frequency : 100 MHz, RBW : 3 MHz,
VBW : 1 MHz, REF : -15 dBm, 23±5 °C
Unit dBm, dBV, dBmV, dBµV, dBµV/m, dBµA/m
(dBµV/m and dBµA/m are used for measurement functions
Average noise level -127 dBm (typical) @ CF : 1 GHz, RBW : 3 kHz, VBW : 100 Hz,
Ref. level < - 40 dBm ( preamp automatically ON)
Frequency response within ±2.0 dB ± 1 dot @50 kHz to 100 MHz
within ±1.0 dB ± 1 dot @100 MHz to max. frequency (3.3 GHz)
Input impedance 50 ?
Input VSWR < 2.0
Input attenuator
Operating range 0 to 25 dB (1 dB step), coupled with reference level
Switching error ±0.6 dB @100 MHz
RBW switching error ±0.6 dB
Display resolution (vertical) 381 dots/10 div
Display scale
Scale 10 dB/div, 5 dB/div, 2 dB/div
Accuracy ±(0.2 dB+1dot)/2 dB ±(0.4 dB+1dot)/5 dB
±(0.8 dB+1dot)/10 dB ±(1.8 dB+1dot)/83 dB
Input damage level +27 dBm (CW average power), 25 VDC
Sweep section
Sweep time
Range 10 ms to 30 s and AUTO
@frequency span : 0 to 2 GHz
30 ms to 30 s and AUTO
@frequency span : full span
Accuracy Within ±0.1 %±1dot
@frequency span : 0 to 2GHz
within ±1.5 %±1dot @ full span
Trigger
Trigger mode AUTO (Available only for zero span)
Trigger source Internal and External
External trigger
Input voltage range 1 to 10 Vp-p
Frequency range  DC to 5 MHz
Input coupling DC coupling
Trigger level approx. 0.56 V(fix)
Input RC approx. 10 k? / less than 15 pF
Input damage level ±50 V(DC+AC peak)
Input connector SMA(J)
Detection mode Positive peak, Negative peak, Sample
Function
Marker measurement NORM:displays frequency (8 digits max) and level (4 digits max) at marker point.
DELTA:displays frequency difference and level difference between two markers
Peak search NORM: searches peak point within 10div (full freq. range). This mode also supports NEXT peak
( up to 10).
ZONE: searches peak point within a zone designated by center and width
Calculations NORM, MAX HOLD, MIN HOLD, AVERAGE, OVER WRITE
MAX/MIN HOLD: 2 to 1024
AVERAGE: 2 to 256
Measurements Measure Channel power, Adjacent channel leakage power, Occupied frequency bandwidth,
Electric field strength (requires antenna), Magnetic field strength (requires magnetic field probe)
Auto tuning Automatically scans the full bandwidth, sets center frequency to the maximum signal within full
span and centers it onscreen. Automatically adjusts reference level, RBW, VBW and sweep time
to optimum values
Save/Load
Save Saves 200 reference spectrum measurements and 200 setups
Load Loads one reference spectrum measurement and one setup
General
RF Input connector N(J) connector
USB Communication
Protocol USB version 1.1 (will also work with USB 2.0 devices)
Device Connector B plug
Transfer rate 12 Mbps
Hard copy USB printer (option) connected to A plug (host) enables hard copy of screen
Host connector A plug
Display
Display 5.7 inch color TFT LCD
Backlight LED backlight
Number of dots 640(H) x 480(V) dots
Power supply
Dedicated Input : 100 to 240 VAC
AC adaptor Output : 9 VDC/2.6 A
Lithium-ion battery 7.4 V/5000 mAh Li-Ion battery (MB400)
Charge function Capable of charging during power-off.
Indicates 4 conditions with two color LED
Charge indicator  5 level indicator of remaining battery charge
Environmental and Size
Operating temperature 0 to 50° C (guaranteed at 23±10 °C, without soft carrying case)
Operating humidity less than 40 °C/80 %RH (guaranteed at less than 33 °C/70 %RH, without soft carrying case)
Storage temperature -20 to 60 °C, less than 60 °C/70 %RH
Dimensions 6.38 (W) x 2.80 (H) x 10.43 (D) inch, 162(W) x 71(H) x 265(D) mm
(excluding projections, protection bumper and stand)
Weight approx. 1.8 kg or 4 lbs (including battery)




For full BK Precision 2650A product specifications, please click here: BK Precision 2650A

BK Precision 2650A Handheld Spectrum Analyzer

Frequency Range:  50Khz to 3.3GHz

Includes Carrying Case & Accessories As Listed

B&K 2650 BK2650

BK Precision 2650A 2650-A Spectrum Analyzer Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 36374-L/T*

  • BK Precision 2650A Handheld 3.3GHz Spectrum Analyzer (BC# 36374-L/T*)
  • Armored Test Port Cable
  • USB PC Interface Cable
  • AC Adapter/Charger
  • Power Cord
  • Case For Unit
  • Carrying Case (G)
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!