Replacement Battery Pack for Fluke 92B

Replacement Battery Pack for Fluke 92B

Fluke 92B ScopeMeter Series II 60MHz Oscilloscope

$0.00
Availability: Out of stock
SKU
11H25

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

ScopeMeter Series II is a battery powered combonation scope and meter designed for measurments on-the-go. Just push the MEASURE MENU button, select one of 30 measurments, and ScopeMeter Series II Automaticly configures itself to take the desired reading.

With ScopeMeter Series II, good waveforms are automatic. While probing from test point to test point, the CONTINUOUS AUTOSET feature instantly adjusts the timebase and amplitude. Manual controls are still there, but Series II is so fast and easy, why use anything else!

Designed with a sealed, ruggedized case, the ScopeMeter Series II performs reliably, even in wet, dusty, or dirty enviroments. And the backlit screen makes for easy readings in brights light and no light situations.

Whether it's an overheating motor, spikeson a circuit, or dimming, flickering lights, the ScopeMeter Series II is ideal for uncovering the source of power quality problems in complex electrical circuits. Series II gives the best accuracy and versatility available in "on-the-go," battery, powered instruments, and measures automatically.

Highlights:

  • Dual input channels
  • Analog-like backlit display
  • Continious autoset
  • Full featured true rms multimeter with special modes
  • Frequency counter
  • Direct access measurment menu
  • TrendPlot current clamp scaling
  • On-line help messages
  • Screen transfers can be made to a PC
  • Sealed against the elements and protected by a shock resistant holster
  • Simultaneously graph and display Min/Max/Average measurments over time for monitoring trends & intermittents
  • Print Directly from ScopeMeter Series II, or download to a PC for further analysis.

Features:

MHz Bandwidth 50
Number Channels 2
Continuous Autoset ?
Measure Menu Automatic Setups ?
Min Max TrendPlot - Long Term Recording ?
Multimeter Display with Full Width Waveform ?
True RMS Volts ?
Continuity Beeper ?
Time/Division (10 ns/div to 60 sec/div) ?
Volts/Division (1mV/div to 100V/div ?
Digital Trigger Delay (Cycles, Events, Time & Zoom ?
Special Multimode Modes (RPM, Temp & More) ?
Scope Input Current Clamp Scaling - Read Amps ?
Glitch Capture - 40 ns ?

Specifications:

SCOPE MODE
Continuous Autoset Hands-free signal probing. Continuously follows input sig-nals from 15 Hz-50 MHz (100 MHz In the Model 105) and automatically selects theproper time base, input range and trigger level.
MIN MAX Envelope Mode Record the waveform excursions with a gray scale envelope on both inputs.
40 ns Glitch Detect Sweep speeds 1 ps/div or slower on Input A
Analog-Like Grey-Scale Display
Waveform Average Smoothing up to 256 waveforms, 10 samples in Roll Mode
Vertical

Frequency response, -3 dB DC to> 50 MHz;
AC coupled <10 Hz direct, <1 Hz with 10:1 probe
Coupling AC, DC, Ground
Rise time <7 ns
Sensitivity (at full 8-bits) 1 mV to 100V/ div to 1 kV/ dlv with 10:1 probe
Current probe scaling 1 mA/div to 100A/div
Modes A,-A, B, -B, A+B, A-B, A=x B=y
Input impedance 1MO, 25 pF direct,10 MO, 13 pF with 10:1 probe
Vertical resolution 8 bit (256 levels)
Accuracy ±(2%+1 pixel)
Horizontal
Sample Rate 25 ms/s
Modes Recurrent, single shot, roll
Ranges
Recurrent 10 ns to 1s / div
Dual input alternating 10 ns to 20 ps / div
Dual input chopped 50 us to 1s/div
Single shot 100 ns to 1s/div
Dual input alternating 100 ns to 20 ps/div
Dual input chopped 50 ps to 1s/div
Roll 2s to 60s/div
Dual input chopped 2s to 60s/div
Accuracy ±(0.1%+ 1 pixel)
Record length 256 or 512 samples (10 or 20 divisions)
Trigger
Sources A, B, or external
Sensitivity : A or B <0.5divlo 10 MHz
<1.5 div to 60 MHz
<4.0div to 100 MHz
External +0.2V or 2.0V (TTL level compatible)
External Input impedance 1 MO, 25 pF direct, 10 MO, 13 pF with 10:1 probe
Delay time -20 div to +640 div
N-cycle trigger Re-triggers after 2 to 255 trigger cycles
Delay by events 1 to 1023 events after External trigger
Zoom Magnifies waveform around the 4th division at the next acquisition (sweep)


For full Fluke 92B product specifications, please click here: Fluke 92B
Fluke 92B/003 ScopeMeter Series II, 25 MS/s Dual-Input 60 MHz Oscilloscope

Includes Carrying Case & Accessories As Listed

Fluke 92B Fluke-92B Scopemeter Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 28970
  • Fluke 92B ScopeMeter Series II (BC# 28970)
  • (2) 1000V Hard Point test Leads
  • (1) 10:1 250 MHz Voltage Probe sets
  • AC Adapter/Charger
  • User manual on Cd-ROM
  • Carrying Case (G)