Anritsu MW9076B1 front

Anritsu MW9076B1 SM Fiber Module For MU250000A

Anritsu MW9076B4 module with accessories

Anritsu MW9076B4 SM Fiber Long Haul OTDR Module

Anritsu MW9076C SM Long Haul Fiber OTDR Module

$0.00
Availability: Out of stock
SKU
3C11

Condition: Refurbished / Calibrated

Warranty: 90 Day Exchange

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

 Anritsu MW9076C SM OTDR Module
High performance three wavelength OTDR for testing at both the two standard SM window, but also the 1625 nm window used for fiber monitoring.


Specifications:
Wavelength 1310/1550/1625 nm +25 nm
Measurable optical fiber 10/125 µm single-mode optical fiber (ITU-T G.652)
Optical connector FC, SC, DIN, HMS-10/A, ST (replaceable, PC type)
Distance range 1, 2.5, 5, 10, 25, 50, 100, 200, 250, 400 km
Pulse width 10, 20, 50, 100, 500, 1000, 2000, 4000, 10000, 20000 ns
Dynamic Range 41.5 dB (1.31 µm)
39.5 dB (1.55 µm)
37 dB (1.625 µm)
Dead Zone
(back-scattered light)
=8 m (1.31 µm)
=9 m (1.55 µm)
=12 m (1.625 µm)
Dead zone (Fresnel reflection) =1.6 m
Marker resolution 0.05 to 800 m
Sampling resolution 0.05 to 80 m
Sampling points Quick mode: 5001, 6251
Normal mode: 20001, 25001
High mode: 40001, 50001
Y-axis scale  0.25, 0.5, 1, 2.5, 5, 10, 15 dB/div (15 dB/div is indicated only at Auto and Full Auto measurement.)
IOR settings 1.400000 to 1.699999 (0.000001 steps)
Distance measurement accuracy ±1 m ±3 x measurement distance x 10ヨ5 ±marker resolution (excluding uncertainty caused by fiber IOR)
Loss measurement accuracy (linearity) ±0.05 dB/dB or ±0.1 dB (whichever is greater)
Return loss measurement accuracy ±2 dB
Automatic measurement Measurement items:
Total loss, total return loss. Each event distance, connection loss, return loss, or reflection amount (displays in table format)
Threshold values
Connection loss: 0.01 to 9.99 dB (in 0.01 dB steps), Return loss: 20 to 60 dB (in 0.1 dB steps),
Fiber-end: 1 to 99 dB (in 1 dB steps)
Warning values
Splice connection loss: 0.1 to 10 dB (in 0.01 dB steps), Connector connection loss: 0.1 to 10 dB (in 0.01 dB steps),
8 Return loss: 10 to 50 dB (in 0.1 dB steps), Fiber loss: 0.01 to 10 dB (in 0.01 dB steps),
Total loss: 0.1 to 60 dB (in 0.1 dB steps), Total return loss: 10 to 50 dB (in 0.1 dB steps),
Average loss: 0.01 to 10 dB (in 0.01 dB steps)
Number of detected events: Up to 99
Automatic setting: Distance range, pulse width, averaging count (time)
Measurement time: =60 s (in full automatic measurement mode)
Connection check: Automatic check of front panel connector connection quality
Communication light check: Check for presence of communication light in optical fiber to be measured
Manual measurement Measurement items:
Transmission loss and distance between 2 points, loss per unit length between 2 points, connection loss, return loss/reflection amount, total return loss, average loss
Real-time sweep: 0.1 to 0.2 second or less
Optical loss measurement light source function Applicable optical fibers:
SM optical fiber (ITU-T G.652)
Optical connectors:
Shared with OTDR (same port)
Light-emitting elements: FP-LD
Center wavelength:
1310/1550 ±25 nm (MW9076B, CW, 25°C)
1310/1550/1625 ±25 nm (MW9076C, CW, 25°C)
Spectrum width:
=5/10 nm (MW9076B, CW, 25°C)
=5/10/10 nm (MW9076C, CW, 25°C)
Output level accuracy:
ヨ3 ±1.5 dBm (CW, 25°C, SM optical fiber: 2 m)
Optical output short term stability:
=0.1 dB [CW, at one point from ヨ10° to +40°C (±1°C), Difference between maximum and minimum values in one min, SM optical fiber cable: 2 m]
Output waveform
CW, 270 Hz, 1 kHz, 2 kHz (Modulated waves are square waves.)
Modulation frequency: 270 Hz/1 kHz/2 kHz ±1.5%
Laser safety specification:
21CFR Class 1, IEC 60825-1 Class 1
Laser safety specification 21CFR Class 1, IEC 60825-1 Class 1
Power =35 W max. (at charging), 4 W (in standard state, MU250000A power consumption included.)
Battery Continuous operation: 6 h (typical value)
Dimensions and mass 290 (W) × 194 (H) × 30 (D) mm (MW9076B/B1/C/J/K main frame)
290 (W) × 194 (H) × 75 (D) mm (MU250000A Display Unit included)
=1.4 kg
=4.0 kg (MU250000A display unit and battery pack included)
Environmental condition Operating temperature and humidity: ヨ10° to 40°C, = 85% (no condensation)
Storage temperature and humidity: ヨ20° to 60°C, = 85%
Vibration: Conforming to MIL-T-28800E Class 3 Shock: 76 cm height, 6 surfaces, 8 corners*12
Dust-proofing: MIL-T-28800E
Drip-proofing: MIL-T-28800E
EMC EN61326: 1997/A2: 2001 (Class A)
EN61000-3-2: 2000 (Class A)
EN61326: 1997/A2: 2001 (Annex A)
LVD EN61010-1: 2001 (Pollution Degree 2)

Anritsu MW9076C SingleMode Long Haul 1310 / 1550 / 1625nm Fiber OTDR Module

Please Note That The Battery Pack For This Module Is Not Included In This Sale

This Sale Is For The MW9076C OTDR Module Only!

Dynamic Range:
1310 / 1550 / 1625 nm : 41.5 / 39.5 / 37 dB

MW9076 MU250000A

Anritsu MW9076C MW-9076C OTDR Module Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 15559

  • Anritsu MW9076C Singlemode Long Haul OTDR Module (Battery Pack Not Included) (BC# 15559) 
    • OTDR Source:
      • 1310nm
      • 1550nm
      • 1625nm
  • (2) SM FC-FC Fiber Cables