Fluke 189 II True RMS Digital Multimeter
$799.00
Availability:
In stock
SKU
10H12
Condition: Refurbished
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- Fluke 189 II True RMS Digital Multimeter (BC# 29352-L/T*)
- (2) Fluke 1000V Hard Point Test Leads
- User Manual On Cd-ROM
- Carrying Case (G)
Request a Quote for
Fluke 189-II True RMS Multimeter
The 189II has more measurement functionality and troubleshooting features to solve more problems in electronics, plant automation, and electro-mechanical equipment. The 189II is the next generation high performance multimeter with more problem solving power, accuracy, safety, and convenience in a handheld multimeter than ever before.
Equipped with new functionality and accuracy, now all included in one handheld test tool such as:
Specifications:
For full FLuke 189 II specifications, please click here: Fluke 189 II
The 189II has more measurement functionality and troubleshooting features to solve more problems in electronics, plant automation, and electro-mechanical equipment. The 189II is the next generation high performance multimeter with more problem solving power, accuracy, safety, and convenience in a handheld multimeter than ever before.
Equipped with new functionality and accuracy, now all included in one handheld test tool such as:
- Large 50,000 count, 320 x 240 Dot matrix LCD display with white backlight. Multiple sets of measurement information are now available in this easy to read display
- 0.025% Basic DC accuracy
- Logging function with TrendCapture. Useful for characterizing the performance of a design or process or for unattended monitoring while in the field. Using on-board TrendCapture users can then graphically view logged readings without needing a pc. Multiple recording sessions are possible before downloading is necessary. Let the 189II become the key component for documenting the performance of your designs, processes or systems while you work on other projects.
- Real time clock for automatic time stamping of saved readings
- True-rms ac voltage and current for accurate measurements on complex signals or non linear loads. AC bandwidth specified to 100 kHz.
- Measure up to 1000Vdc and 1000Vac.
- Measure up to 10 A (20 A for 30 seconds)
- 100 mF capacitance range
- Temperature function
- Peak capture to record transients as fast as 250 µs
- Dual rated CAT IV 600V-CAT III 1000V.
Specifications:
Voltage DC | |
Accuracy | 0.025 % |
Range and Resolution | 50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V |
Voltage AC | |
Accuracy | 0.4 %(true-rms) |
Range and Resolution | 50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V |
Current DC | |
Accuracy | 0.06 % |
Range and Resolution | 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
Current AC | |
Accuracy | 0.6%(true-rms) |
Range and Resolution | 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
Temperature (excluding probe) | |
Accuracy | 1.0 % |
Range and Resolution | -200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F) |
Resistance | |
Accuracy | 0.05 % |
Range and Resolution | 500.00 ?, 5.0000 k?, 50.000 k?, 500.00 k?, 5.0000 M?, 50.00 M?, 500.0 M? |
Capacitance | |
Accuracy | 1.0 % |
Range and Resolution | 1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100.00 mF |
Frequency | |
Accuracy | 0.005% + 5 |
Range and Resolution | 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
Additional functions/features | Multiple on-screen displays: Yes True-rms AC bandwidth: 100 kHz DBV/dBm: Yes Conductance: 50.00nS Continuity beeper: Yes Battery/Fuse access: Battery / Fuse Peak: 250 µS Elapse time clock: Yes Time of day clock: Yes Min-Max-Avg: Yes Duty Cycle: 0.01 % to 99.99 % Pulse Width: 0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms Hold: Yes Isolated Optical Interface: Yes Auto/Touch Hold: Yes Reading memory: Yes Log to PC: Yes Interval/Event Logging: Yes Logging Memory: Up to 10,000 readings |
Environmental Specifications | |
Operating Temperature | -20 °C to +55 °C |
Storage Temperature | -40 °C to +60 °C |
Relative Humidity | 0% to 90% (0 °C - 37 °C) 0% to 65% (37 °C - 45 °C), 0 to 45 % (45 °C - 55 °C |
Electromagnetic Compatability | EMC EN6 1326-1 |
Vibration | Random vibration per MIL-PRF-28800f Class 2 |
Shock | 1 meter drop per IEC/EN 61010-1 2nd edition |
Safety Specifications | |
Overvoltage category | CAT III 1000 V / CAT IV 600 V safety rated |
Agency Approvals | CSA, UL, TÜV, CE |
Mechanical & General Specifications | |
Maximum voltage between any terminal and earth ground | 1000V |
Size | (HxWxL 22.2 cm x 10.2 cm x 6 cm (8.75 in x 4.03 in x 2.38 in) |
Weight | 870.9 g (28 oz) |
Battery Life | 100 minimum, 200 hours in logging mode |
Battery type | 6 AA alkaline batteries, NEDA 15A IEC LR6 |
For full FLuke 189 II specifications, please click here: Fluke 189 II