Fluke 41 Power Harmonics Analyzer

$695.00
Availability: In stock
SKU
PH02

Condition: Refurbished / Calibrated

Warranty: 1 YEAR WARRANTY

 Fluke 41 Power Harmonics Analyzer
You can use the Tester to measure voltage and current inputs at power line and harmonic frequencies. Using these inputs, the Tester automatically calculates power and a wide range of other measurements useful in determining harmonic distortion levels and sources.

These capabilities allow you to monitor power quality before and after an installation, troubleshoot a power distribution system, and print out or download data for additional analysis.

The Tester is both a harmonics measurement tool and a power meter or digital multimeter. You can use the Tester to measure voltage events (undervoltage, overvoltage, line outages, and neutral to ground levels), current levels, or to measure power levels. Fundamental frequency measurements (to 100 Hz) and harmonic frequency measurements (to about 2 kHz) are also possible.

The Tester cannot measure frequencies above about 2 kHz.

Applications:
  • Plant Switch Gear
    • Measure current, load balance, total harmonic distortion.
  • Electronic Equipment Load Center
    • Measure for excessive current (tripping of circuit breakers) and other general measurement uses such as level of current flow in each circuit. Measure balance between phases, neutral current and frequency, harmonic distortion.
  • Generator Set
    • Measure for excessive current, proper frequency, and other general uses.
  • Adjustable Frequency Motor Drive
    • Measure input and output frequency and input and output current. The Tester measures the output current frequency of the drive. Input power and harmonic currents can also be measured.

Specifications:
Minimum input levels 5V rms (Using V reference)
or 1A rms (Using A reference)
VOLTS Measurements (True RMS)
Input Range: 0.0V to 600V rms (ac + dc)
0.0V to +/- 933V peak
Basic Accuracy (Fundamental 5 - 65 Hz, dc)
rms:
peak, dc:

+/-(0.5% + 2 digits)
+/-(2% + 3 digits)
Input Impedance: 1 MO, balanced
Crest factor: > 3.0 below 300V, 1.56 @ 600V
AMPS Measurements (TRUE RMS)
(1 mV/A) Isolated Input
Input Range: 1.00 mV (A) to 1000 mV rms (A) (ac + dc)
1.0 mV (A) to +/- 2000 mV (A) peak
Basic Accuracy (Fundamental 5 Hz - 65 Hz, dc)
rms:
peak, dc:

+/-(0.5% + 3 digits) + probe specs.
+/-(2% + 4 digits) + probe specs.
Input impedance: 1 MO II 47 pF
Crest factor: > 3.0 below 600 mV, 2.0 @ 1000 mV
WATTS MEASUREMENTS (VOLT-AMPS)
(1 mV/A) Isolated Input
Range: 0 W (VA) to 600 kW (kVA) average
0 W (VA) to 2000 kW (kVA) peak
Accuracy
Active (average) W (VA):
(Fundamental 5 Hz - 65 Hz, dc)
(1% + 4 digits) + probe specs
HARMONICS MEASUREMENT ACCURACY (CURSOR DATA)
Volts:
Fundamental to 13th harmonic
Volts:
Phase:

+/- (2% + 2 digits)
+/- 2 degrees (harmonic > 5%)
13th to 31st Harmonic
Volts:
Phase:

13th (+/- (2% + 2 digits)) --- 31st (+/-(8% + 2 digits))
+/- 10 degrees (harmonic > 5%)
Amps & Watts
Fundamental to 13th harmonic
Amps or Watts:
Phase:

13th (+/- (3% + 3 digits) + Probe Specs) --- 31st (+/-(8% + 3 digits) + Probe Specs)
+/- 10 degrees + probe specs (harmonic > 5%)
FREQUENCY MEASUREMENT ACCURACY (Fundamental, 5.0 Hz - 99.9 Hz)
5.0 Hz - 99.9 Hz +/- 0.3 Hz
OTHER MEASUREMENT SPECIFICATIONS
Input Bandwidth: (-0.5 dB) DC, 5 Hz to 2.1 kHz
Crest Factor (CF) Range: 1.00 to 5.00
Power Factor (PF): 0.00 to 1.00
Displacement Power Factor (DPF): 0.00 to 1.00
Phase Measurement Range: -179 to 180 degrees
K-Factor (KF) Range: 1.00 to 30.00
GENERAL SPECIFICATIONS
Size: 9.2 x 3.9 x 2.5 inches (234 x 100 x 64 mm)
Weight: 2.0 lbs (1 kg)
Input connectors:
Voltage:
Current Probe:

2 shrouded banana jacks (4 mm)
1 shrouded BNC jack
Battery:
Type:
Operating Time:

4 Alkaline "C" Cells ANSI/NEDA-14A, IEC-LR14
24 hours, minimum (continuous, without backlight)
Alternate Battery: 4 NiCad Cells, customer supplied and externally charged. The tester prevents battery reversal by turning itself off if battery voltage drops below 4.0V dc
Temperature:
Operating
Storage:

0 to 50°C (32 to 122°F)
-20 to 60°C (-4 to 140°F)
Temperature Coefficient: 0.1 x Specified Accuracy per degree C
(0 to 18 degrees C, 28 to 50 degrees C)
Humidity (non-condensing):
Operating:


Storage:

0 - 30°C: 90%
30 - 40°C: 75%
40 - 50°C: 45%
90%
Altitude:
Operating:
Storage:

10,000 feet (3 km)
40,000 feet (12 km)
Shock & Vibration: per MIL-T 28800, class 3, sinusoidal, non-operating
Electro-Magnetic Interference:
RF Emissions:


RF Suscepitibility:

EN 50081-1 Commercial Limits,
FCC Part 15 Class B,
VFG 243-1991
EN 50082-2 Industrial Limits
Spray Proof and Dust Proof Case: per IEC 529, Section 3;
IP 52 Dust-Protected, Drip Proof
DISPLAY
Type: Super Twisted Liquid Crystal
Size: 3.0 inch diagonal (76 mm)
Resolution: 160 W x 128 H pixels
Contrast: User adjustable
Backlight: Yellow-green LED





For full Fluke 41 specifications, please click here: Fluke 41

Fluke 41 HandHeld Power Harmonics Analyzer

You can use the Tester to measure voltage events (undervoltage, overvoltage, line outages, and neutral to ground levels), current levels, or to measure power levels

Includes Fluke 80i-500s AC Current Probe, Hard Carrying Case & Accessories As Listed

41

Fluke 41 Fluke-41 Power Harmonics Analyzer Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

BC# 16706

  • Fluke 41 Power Harmonics Analyzer (BC# 16706-L/T*) 
  • (2) Fluke TP20 Industrial Test Probes (1-Red, 1-Black)
  • (2) Fluke Test Leads (1-Red, 1-Black)
  • Fluke 80i-500s AC Current Probe w/ Instructions
  • (2) Fluke AC20 Alligator Clips (1-Red, 1-Black)
  • (2) Fluke Test Pins (1-Red, 1-Black)
  • Fluke Accessories Guide
  • User Manual On CD-ROM
  • Hard Carrying Case
Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!