Fluke 41 Power Harmonics Analyzer
$695.00
Availability:
In stock
SKU
PH02
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- Fluke 41 Power Harmonics Analyzer (BC# 16706-L/T*)
- (2) Fluke TP20 Industrial Test Probes (1-Red, 1-Black)
- (2) Fluke Test Leads (1-Red, 1-Black)
- Fluke 80i-500s AC Current Probe w/ Instructions
- (2) Fluke AC20 Alligator Clips (1-Red, 1-Black)
- (2) Fluke Test Pins (1-Red, 1-Black)
- Fluke Accessories Guide
- User Manual On CD-ROM
- Hard Carrying Case
Request a Quote for
Fluke 41 Power Harmonics Analyzer
You can use the Tester to measure voltage and current inputs at power line and harmonic frequencies. Using these inputs, the Tester automatically calculates power and a wide range of other measurements useful in determining harmonic distortion levels and sources.
These capabilities allow you to monitor power quality before and after an installation, troubleshoot a power distribution system, and print out or download data for additional analysis.
The Tester is both a harmonics measurement tool and a power meter or digital multimeter. You can use the Tester to measure voltage events (undervoltage, overvoltage, line outages, and neutral to ground levels), current levels, or to measure power levels. Fundamental frequency measurements (to 100 Hz) and harmonic frequency measurements (to about 2 kHz) are also possible.
The Tester cannot measure frequencies above about 2 kHz.
Applications:
Specifications:
For full Fluke 41 specifications, please click here: Fluke 41
You can use the Tester to measure voltage and current inputs at power line and harmonic frequencies. Using these inputs, the Tester automatically calculates power and a wide range of other measurements useful in determining harmonic distortion levels and sources.
These capabilities allow you to monitor power quality before and after an installation, troubleshoot a power distribution system, and print out or download data for additional analysis.
The Tester is both a harmonics measurement tool and a power meter or digital multimeter. You can use the Tester to measure voltage events (undervoltage, overvoltage, line outages, and neutral to ground levels), current levels, or to measure power levels. Fundamental frequency measurements (to 100 Hz) and harmonic frequency measurements (to about 2 kHz) are also possible.
The Tester cannot measure frequencies above about 2 kHz.
Applications:
- Plant Switch Gear
- Measure current, load balance, total harmonic distortion.
- Electronic Equipment Load Center
- Measure for excessive current (tripping of circuit breakers) and other general measurement uses such as level of current flow in each circuit. Measure balance between phases, neutral current and frequency, harmonic distortion.
- Generator Set
- Measure for excessive current, proper frequency, and other general uses.
- Adjustable Frequency Motor Drive
- Measure input and output frequency and input and output current. The Tester measures the output current frequency of the drive. Input power and harmonic currents can also be measured.
Specifications:
Minimum input levels | 5V rms (Using V reference) or 1A rms (Using A reference) |
VOLTS Measurements (True RMS) | |
Input Range: | 0.0V to 600V rms (ac + dc) 0.0V to +/- 933V peak |
Basic Accuracy (Fundamental 5 - 65 Hz, dc) rms: peak, dc: |
+/-(0.5% + 2 digits) +/-(2% + 3 digits) |
Input Impedance: | 1 MO, balanced |
Crest factor: | > 3.0 below 300V, 1.56 @ 600V |
AMPS Measurements (TRUE RMS) | |
(1 mV/A) Isolated Input | |
Input Range: | 1.00 mV (A) to 1000 mV rms (A) (ac + dc) 1.0 mV (A) to +/- 2000 mV (A) peak |
Basic Accuracy (Fundamental 5 Hz - 65 Hz, dc) rms: peak, dc: |
+/-(0.5% + 3 digits) + probe specs. +/-(2% + 4 digits) + probe specs. |
Input impedance: | 1 MO II 47 pF |
Crest factor: | > 3.0 below 600 mV, 2.0 @ 1000 mV |
WATTS MEASUREMENTS (VOLT-AMPS) | |
(1 mV/A) Isolated Input | |
Range: | 0 W (VA) to 600 kW (kVA) average 0 W (VA) to 2000 kW (kVA) peak |
Accuracy Active (average) W (VA): |
(Fundamental 5 Hz - 65 Hz, dc) (1% + 4 digits) + probe specs |
HARMONICS MEASUREMENT ACCURACY (CURSOR DATA) | |
Volts: | |
Fundamental to 13th harmonic Volts: Phase: |
+/- (2% + 2 digits) +/- 2 degrees (harmonic > 5%) |
13th to 31st Harmonic Volts: Phase: |
13th (+/- (2% + 2 digits)) --- 31st (+/-(8% + 2 digits)) +/- 10 degrees (harmonic > 5%) |
Amps & Watts | |
Fundamental to 13th harmonic Amps or Watts: Phase: |
13th (+/- (3% + 3 digits) + Probe Specs) --- 31st (+/-(8% + 3 digits) + Probe Specs) +/- 10 degrees + probe specs (harmonic > 5%) |
FREQUENCY MEASUREMENT ACCURACY (Fundamental, 5.0 Hz - 99.9 Hz) | |
5.0 Hz - 99.9 Hz | +/- 0.3 Hz |
OTHER MEASUREMENT SPECIFICATIONS | |
Input Bandwidth: (-0.5 dB) | DC, 5 Hz to 2.1 kHz |
Crest Factor (CF) Range: | 1.00 to 5.00 |
Power Factor (PF): | 0.00 to 1.00 |
Displacement Power Factor (DPF): | 0.00 to 1.00 |
Phase Measurement Range: | -179 to 180 degrees |
K-Factor (KF) Range: | 1.00 to 30.00 |
GENERAL SPECIFICATIONS | |
Size: | 9.2 x 3.9 x 2.5 inches (234 x 100 x 64 mm) |
Weight: | 2.0 lbs (1 kg) |
Input connectors: Voltage: Current Probe: |
2 shrouded banana jacks (4 mm) 1 shrouded BNC jack |
Battery: Type: Operating Time: |
4 Alkaline "C" Cells ANSI/NEDA-14A, IEC-LR14 24 hours, minimum (continuous, without backlight) |
Alternate Battery: | 4 NiCad Cells, customer supplied and externally charged. The tester prevents battery reversal by turning itself off if battery voltage drops below 4.0V dc |
Temperature: Operating Storage: |
0 to 50°C (32 to 122°F) -20 to 60°C (-4 to 140°F) |
Temperature Coefficient: | 0.1 x Specified Accuracy per degree C (0 to 18 degrees C, 28 to 50 degrees C) |
Humidity (non-condensing): Operating: Storage: |
0 - 30°C: 90% 30 - 40°C: 75% 40 - 50°C: 45% 90% |
Altitude: Operating: Storage: |
10,000 feet (3 km) 40,000 feet (12 km) |
Shock & Vibration: | per MIL-T 28800, class 3, sinusoidal, non-operating |
Electro-Magnetic Interference: RF Emissions: RF Suscepitibility: |
EN 50081-1 Commercial Limits, FCC Part 15 Class B, VFG 243-1991 EN 50082-2 Industrial Limits |
Spray Proof and Dust Proof Case: | per IEC 529, Section 3; IP 52 Dust-Protected, Drip Proof |
DISPLAY | |
Type: | Super Twisted Liquid Crystal |
Size: | 3.0 inch diagonal (76 mm) |
Resolution: | 160 W x 128 H pixels |
Contrast: | User adjustable |
Backlight: | Yellow-green LED |
For full Fluke 41 specifications, please click here: Fluke 41