Fluke 98 Automotive Dual Channel Scopemeter
$795.00
Availability:
Out of stock
SKU
10H07
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
Request a Quote for
- Fluke 98 Automotive Scopemeter (BC# 31849-L/T*)
- Fluke RPM90 Inductive Pickup
- Fluke Coax To BNC Cable
- Fluke Capacitive Secondary Pickup
- Automotive Electronics 10X Auto Probe
- Coax To Dual Clip Cable
- BNC To Dual Ground Lead Cable
- Fluke STL90 Test Lead Set Red
- (2) Fluke Voltage Proibe Test Leads
- (4) Fluke Alligator Clips
- (2) Ground Leads
- Fluke Flexible Test Lead
- Accessory Case
- AC Adapter/Charger
- Hard Copy User Manual
- Carrying Case (G)
Fluke 98 Automotive Scopemeter
Your new Fluke Automotive ScopeMeter® test tool is a powerful instrument with a wide variety of capabilities.
Automated Sensor Tests
The Sensors menu gives direct access to a wide variety of sensor measurements. The best operating mode is automatically selected. A few of the sensors tested automatically include:
Continuous AutoRange
Hands-off signal probing. Continuously tracks input signals from 4 Hz to 5 MHz and automatically selects the proper time base, input range, trigger level, trigger slope, and trigger source.
40 ns Glitch detect
Sweep speeds 1 ms per division or slower
Cursor Measurements
Single input (INPUT A) cursor measurements:
Voltage at CURSOR 1.
Voltage at CURSOR 2.
Voltage difference (V) between the CURSOR 1 and CURSOR 2 positions.
Time difference (t) between the CURSOR 1 and CURSOR 2 positions.
Dual input cursor measurements:
Voltage at CURSOR 1 on the INPUT A signal waveform.
Voltage at CURSOR 1 on the INPUT B signal waveform.
Voltage at CURSOR 2 on the INPUT B signal waveform.
Voltage at CURSOR 2 on the INPUT A signal waveform.
Time difference (t) between the CURSOR 1 and CURSOR 2 positions
Meter Mode
Displays numeric reading and waveform of the signal on INPUT A.
Measurement readout: ............................... Absolute, relative (set zero function).
Record Capabilities
Plot Readings
Plots up to 4 readings over time simultaneously.
Min Max Trendplot
Logs minimum, maximum, and average readings to memory at full accuracy and displays all three as graphs. Uses automatic vertical scaling and horizontal time compression for hands-off recording from a minimum of 60 seconds to a maximum 32 days full screen. The horizontal time compression process records data until the screen is full. Then it selects the greater maximum and the lesser minimum between each pair of readings. These readings are then compressed to fill half the screen. The process then repeats itself until up to 32 days have passed.
Intermittent Record
Monitors and records signal continuously for a full 128 screens (single channel) or 64 screens (dual channel) of data. Intermittent recording is initiated on entry and is terminated at any time by pressing any key on the instrument (except ON/OFF).Time base ranges 20 ms per division and slower (> 20 ms/division).
Flight Record
Records up to 40 successive screen snapshots in memory. Preserves the last 40 screens in an endless loop fashion. Time base ranges 200 ms per division and faster (< 200 ms/division).
The Fluke 98 series including standard accessories, conforms with the EEC Directive 89/336 for EMI immunity, as defined by IEC 801-3, with the addition of the following tables (1 to 12)
Table 1
Table 2
Table 3
For conditions not specified in tables 1,2, and 3, a susceptibility effect of more than 10% is possible.
Multimeter Mode:
Table 4
Table 5
Table 6
Automated Oxygen Sensor Test:
Table 7
Table 8
Table 9
For conditions not specified in tables 7,8 , and 9, a susceptibility effect of more than 10% is possible.
Engine Test, ignition pattern: Secondary DIS:
Table 10
Table 11
Table 12
Safety
Designed to Category III per IEC 1010 approved for 600V measurements on industrial power distribution systems.
Your new Fluke Automotive ScopeMeter® test tool is a powerful instrument with a wide variety of capabilities.
- Its menu-driven interface has automatic configurations for most of your tests, so you will find that the test tool is easy to use.
- Continuous AUTO RANGE, an exclusive Fluke feature, constantly acquires and displays the best possible signal.
- The secondary ignition pickup and automated ignition functions make it easy for you to analyze an ignition system malfunction.
- The Relative Compression mode helps you quickly find a low compression cylinder.
- The Secondary Ignition Single function displays the waveform along with the spark voltage, RPM, burn time and burn voltage.
- The Intermittent Record function can find and display such a problem. This record function can record up to 1280 divisions of continuous information.
- The Flight Record function records screen snapshots from 200ms per division up to full time base speed.
- The Plot Readings function allows you to plot up to four different readings of a signal over time with a single connection.
- Min/Max Trendplot continuously monitors the minimum, maximum, and average value of a signal's readings with time stamp
Engine Tests | |
RPM | 600 - 15,000 RPM, 1 RPM resolution <1000 RPM, 10 RPM resolution >1000 RPM |
Dwell Range | Degree: 0 to 360°, 1° resolution Milliseconds: 0 to 1,000 ms (1 ms resolution) Percentage: 0% - 100%, resolution 3 digits |
Timing Advance (TDC) | in degrees (°) crankshaft rotation |
Primary Voltage | 0 to 300V |
Secondary Voltage | 0 to 80 kV |
Burn Time | 0.6 ms to 5 ms |
Burn Voltage | 0 to 80 kV |
Relative Compression | 0 to -100% contribution |
Alternator Ripple Voltage | 0 to 300V |
Battery Condition Test | 0 to 40V |
Fuel Injection Pulse Width | 0 to 1800 ms |
Systems Automatically Tested: | Saturated Driver Conventional Throttle Body Injection Systems Current Controlled Peak And Hold Pulse Modulated |
IGNITION TYPE | PRIMARY | SECONDARY |
||
SINGLE | PARADE | PARADE | PARADE | |
Conventional | X | X | X | X |
DIS | X | X | ||
Coil on Plug | X |
Diesel Tests (with Optional DPS90 Diesel Probe Set) | |
Engine Speed | 400 to 10,000 RPM |
Advance (Diesel Pump Timing) | in ° of crankshaft rotation |
Injection Pulse | 10 µs to 1200 ms |
Automated Sensor Tests
The Sensors menu gives direct access to a wide variety of sensor measurements. The best operating mode is automatically selected. A few of the sensors tested automatically include:
- Mass Air Flow Sensor (MAF)
- Manifold Absolute Pressure (MAP)
- Oxygen Sensor (Zirconium and Titanium)
- Dual Oxygen Sensor
- Temperature Sensors
- Position Sensors
- Camshaft Position
- Exhaust Gas Recirculation (EGR)
- Ride Height Sensors
- Magnetic Sensors
- Speed Sensors
- Knock Sensors
- Distributor Triggering
- Mixture Control (Feedback)
- Frequency Control Valve (CIS E)
- Air Flow Meter
- Idle Air Compensation
- Exhaust Gas Recirculation (EGR)
- Battery Condition Test
- Charging
- Diode Test
- Field Control
- Ripple Voltage Measurement
- Cranking
- Voltage Reference And Ground
- Voltage Drop
- Clamping Diode
- Solenoid Tests
- Stepper Motor
Continuous AutoRange
Hands-off signal probing. Continuously tracks input signals from 4 Hz to 5 MHz and automatically selects the proper time base, input range, trigger level, trigger slope, and trigger source.
40 ns Glitch detect
Sweep speeds 1 ms per division or slower
Vertical | |
Frequency Response, -3 dB | DC to > 5 MHz with Filter Adapter DC to > 2.5 kHz |
AC coupled | <10 Hz direct |
Coupling | AC, DC |
Sensitivity | 5 mV to 100 V/div |
Modes | A, -A, B, -B |
Input Impedance | 1 MO//55 pF direct, 10 MO//4 pF with Filter Adapter |
Vertical Resolution | 8 bit (256 levels) |
Accuracy | ± 2% +1 pixel) |
Horizontal | |
Modes | Recurrent, Single Shot, Roll |
RANGES: | |
Recurrent | 20 µs to 1 s/div |
Dual input alternating | 1 µs to 20 µs/div |
Dual input chopped | 50 µs to 1 s/div |
Single Shot | 1 µs to 200 ms/div |
Roll | 500 ms to 60 s/div |
Dual input chopped | 20 µs to 60 s/div |
Accuracy | ±(0.1% + 1 pixel) |
Record Length | 512 samples (20 divisions) |
Trigger | |
Sources | A, B or TRIGGER (external) |
Sensitivity: A or B | <0.5 div to 1 MHz <1.5 div to 5.5 MHz |
Sensitivity: TRIGGER | +0.2V and 2.0V (TTL level compatible) |
External Input Impedance | 1.5 M//40 pF direct |
Delay Time | -1 div |
Cursor Measurements
Single input (INPUT A) cursor measurements:
Voltage at CURSOR 1.
Voltage at CURSOR 2.
Voltage difference (V) between the CURSOR 1 and CURSOR 2 positions.
Time difference (t) between the CURSOR 1 and CURSOR 2 positions.
Dual input cursor measurements:
Voltage at CURSOR 1 on the INPUT A signal waveform.
Voltage at CURSOR 1 on the INPUT B signal waveform.
Voltage at CURSOR 2 on the INPUT B signal waveform.
Voltage at CURSOR 2 on the INPUT A signal waveform.
Time difference (t) between the CURSOR 1 and CURSOR 2 positions
Meter Mode
Displays numeric reading and waveform of the signal on INPUT A.
Measurement readout: ............................... Absolute, relative (set zero function).
DC Voltage | |
Ranges | direct input with STL90 leads ..... 100 mV, 300 mV, 1V, 3V, 10V, 30V, 100V, 300V |
Accuracy | ±(0.5% +5 counts) |
Full Scale Reading | 1000 or 3000 counts |
Normal Mode Rejection | >50 dB at 50 or 60 Hz |
Common Mode Rejection | >100 dB at DC, 50, 60, or 400 Hz |
AC or AC+DC True RMS Voltage | |
Ranges direct input |
100 mV, 300 mV, 1V, 3V, 10V, 30V, 100V, 250V |
Accuracy (valid from 5% range) | 50 Hz to 60 Hz ±(1% +10 counts) 20 Hz to 20 kHz ±(2% +15 counts) 5 Hz to 1 MHz ±(3% +20 counts) |
Full Scale Reading | 1000 or 3000 counts |
Crest Factor | Automatic ranging on crest factor overload |
Common Mode Rejection Ratio | >60 dB, DC to 60 Hz |
Frequency | 1 Hz to 5 MHz |
Resolution | 4 digits |
Accuracy | ±(0.5% +2 counts) |
RPM | selectable: n pulses/720° |
Range | 600 RPM to 5,000 RPM |
Resolution | 4 digits |
Accuracy | ±(1% +5 counts) |
Duty Cycle positive or negative pulse | |
Range | 2.0% to 98.0% |
Accuracy (logic or pulse waveforms) | ±(0.5% +2 counts) |
Pulse Width positive or negative pulse | |
Range | 250 µs to 50 ms |
Resolution | 3 digits |
Accuracy | ±(0.5% +2 counts) |
°C / °F Temperature for optional temperature probes | |
TR90: Range | -50 °C to +200 °C (-58 to +392 °F) |
Accuracy | ±(1% +0.5 °C) |
Other: Scaling | 1 mV/degree |
Amperes for optional current probes | |
Scaling | 1 mV/A, 10 mV/A, 100 mV/A, 1 V/A (1 mV/mA) |
Coupling | DC, AC rms, or AC+DC rms |
Range | 2000A maximum |
Resistance | |
Ranges | 30O, 300O, 3 kO, 30 kO, 300 kO, 3 MO, 30 MO |
Accuracy (300O to 30 MO) | ±(0.5% +5 counts) |
Accuracy (30O) | ±(2.5% +25 counts) |
Full Scale Reading | 3000 counts |
Measurement Current | 500µA, 500 µA, 70 µA, 7 µA, 700 nA, 70 nA, 70 nA |
Open Circuit Voltage | <4V |
Full Scale Voltage | <250 mV to 3 MO, <2V to 30 MO |
Diode Test | |
Open Circuit Voltage | <4V |
Full Scale voltage | 2.800V |
Measuring Current | 0.5 mA |
Measurement Modifying Functions | |
SMOOTH | Moving average of readings up to last 8 seconds. |
Fast Update | Fast display update for IGNITION single cylinder test |
FREEZE (HOLD) | Holding of last stable reading on display |
SET ZERO | Zeros present reading as a reference value |
Record Capabilities
Plot Readings
Plots up to 4 readings over time simultaneously.
Min Max Trendplot
Logs minimum, maximum, and average readings to memory at full accuracy and displays all three as graphs. Uses automatic vertical scaling and horizontal time compression for hands-off recording from a minimum of 60 seconds to a maximum 32 days full screen. The horizontal time compression process records data until the screen is full. Then it selects the greater maximum and the lesser minimum between each pair of readings. These readings are then compressed to fill half the screen. The process then repeats itself until up to 32 days have passed.
Intermittent Record
Monitors and records signal continuously for a full 128 screens (single channel) or 64 screens (dual channel) of data. Intermittent recording is initiated on entry and is terminated at any time by pressing any key on the instrument (except ON/OFF).Time base ranges 20 ms per division and slower (> 20 ms/division).
Flight Record
Records up to 40 successive screen snapshots in memory. Preserves the last 40 screens in an endless loop fashion. Time base ranges 200 ms per division and faster (< 200 ms/division).
Screen Memories (Save or Recall) | |
Memory | 15 complete display screens including setup |
Test Lead Calibration | DC adjustment for 10:1 test leads only |
General Specifications | |
Functional on These Engine Types: | |
Number of Cylinders | 1, 2, 3, 4, 5, 6, 8 |
Engine Stroke | 2 or 4 stroke |
Fuel Types | Gasoline, Diesel |
Ignition Systems | Conventional, DIS, Coil-on-Plug |
Electrical System Voltages | 6, 12, 24V (Use gasoline settings for alternative fuel tests) |
The accuracy of all measurements are within +(% of reading + number of counts) from 18 °C to 28 °C. Add 0.1 x (specific accuracy) for each °C <18 °C or >28 °C. |
|
Display | |
Type | Foil Compensated Super Twisted Liquid Crystal |
Size | 84 x 84 mm (4.7" diagonal) |
Resolution | 240 x 240 pixels |
Contrast | User adjustable |
Backlight | Cold Cathode Fluorescent (CCFL) Tube |
High Brightness | 50 cd/m |
External Power Requirements | |
Internal Battery Pack | NiCad 4.8V nominal |
Operating Time | Typically 4 hours |
Power Adapter/Battery Charger | |
Charging Time | Typically 16 hours |
Alternate battery | 4 Alkaline C cells (non-rechargeable) |
External Supply | 8 to 20V DC, 5 W typical via 5 mm jack |
Environmental | |
Temperature Operating |
0 °C to 50 °C |
Storage | -20 °C to 70 °C |
Humidity | |
Operating | 20 °C to 30 °C, 90% RH noncondensing 30 °C to 50 °C, 70% RH noncondensing |
Storage | 95% RH |
Altitude | |
Operating | 3 km (10,000ft) |
Storage | 12 km (40,000ft) |
Shock and Vibration | per MIL-T-28800 for Class 3 |
The Fluke 98 series including standard accessories, conforms with the EEC Directive 89/336 for EMI immunity, as defined by IEC 801-3, with the addition of the following tables (1 to 12)
Table 1
Susceptibility: no visible disturbance | |||
Frequency range: 10 kHz - 25 MHz |
E = < 0.1 V/m | E = 1 V/m | E = 3 V/m |
Stand alone / with STL90 |
5 mV/div - 100 V/div | 5 mV/div - 100 V/div | 5 mV/div - 100 V/div |
Table 2
Susceptibility: no visible disturbance | |||
Frequency range: 25 MHz ... 1 GHz |
E = < 0.1 V/m | E = 1 V/m | E = 3 V/m |
Stand alone | 5 mV/div - 100 V/div | 5 mV/div - 100 V/div | 5 mV/div - 100 V/div |
With STL90 | 5 mV/div - 100 V/div | 200 mV/div - 100 V/div | 500 mV/div-100 V/div |
Table 3
Susceptibility: disturbance less than 10% of full scale | |||
Frequency range: 25 MHz ... 1 GHz |
E = < 0.1 V/m | E = 1 V/m | E = 3 V/m |
Stand alone | N/A | N/A | N/A |
With STL90 | N/A | 50 mV/div - 100mV/div | 100 mV/div - 200 mV/div |
For conditions not specified in tables 1,2, and 3, a susceptibility effect of more than 10% is possible.
Multimeter Mode:
Table 4
Susceptibility: no visible disturbance | |||
Frequency range: 10 kHz ... 25 MHz |
E = < 0.1 V/m | E = 1 V/m | E = 3 V/m |
Stand alone / with STL90 |
100 mV - 300V | 100 mV - 300V | 300 mV - 300V |
Table 5
Susceptibility: no visible disturbance | |||
Frequency range: 25 MHz ... 1 GHz |
E = < 0.1 V/m | E = 1 V/m | E = 3 V/m |
Stand alone | 100 mV - 300V | 100 mV - 300V | 100 mV - 300V |
With STL90 | 100 mV - 300V | 100 mV - 300V | 300 mV - 300V |
Table 6
Susceptibility: disturbance less than 10% of full scale | |||
Frequency range: 25 MHz ... 1 GHz |
E = < 0.1 V/m | E = 1 V/m | E = 3 V/m |
Stand alone | N/A | N/A | N/A |
With STL90 | N/A | N/A | 100 mV |
Automated Oxygen Sensor Test:
Table 7
Susceptibility: no visible disturbance | |||
Frequency range: 10 kHz ... 25 MHz |
E = < 0.1 V/m | E = 1 V/m | E = 3 V/m |
Stand alone / with STL90 + filter adapter |
50 mV/div - 10 V/div | 50 mV/div - 10 V/div | 50 mV/div - 10 V/div |
Table 8
Susceptibility: no visible disturbance | |||
Frequency range: 25 MHz ... 1 GHz |
E = < 0.1 V/m | E = 1 V/m | E = 3 V/m |
Stand alone | 50 mV/div - 10 V/div | 50 mV/div - 10 V/div | 50 mV/div - 10 V/div |
With STL90 + filter adapter |
50 mV/div - 10 V/div | 100 mV/div - 10 V/div | 200 mV/div - 10 V/div |
Table 9
Susceptibility: disturbance less than 10% of full scale | |||
Frequency range: 25 MHz ... 1 GHz |
E = < 0.1 V/m | E = 1 V/m | E = 3 V/m |
Stand alone | N/A | N/A | N/A |
With STL90 | N/A | 50 mV/div | 100 mV/div |
For conditions not specified in tables 7,8 , and 9, a susceptibility effect of more than 10% is possible.
Engine Test, ignition pattern: Secondary DIS:
Table 10
Susceptibility: no visible disturbance | |||
Frequency range: 10 kHz ... 25 MHz |
E = < 0.1 V/m | E = 1 V/m | E = 3 V/m |
Stand alone / with PM9096/101 |
500 V/div - 20 kV/div | 500 V/div - 20 kV/div | 500 V/div - 20 kV/div |
Table 11
Susceptibility: no visible disturbance | |||
Frequency range: 25 MHz ... 1 GHz |
E = < 0.1 V/m | E = 1 V/m | E = 3 V/m |
Stand alone | 500 V/div - 20 kV/div | 500 V/div - 20 kV/div | 500 V/div - 20 kV/div |
With PM9096/101 | 500 V/div - 20 kV/div | 500 V/div - 20 kV/div | 1 kV/div - 20 kV/div |
Table 12
Susceptibility: disturbance less than 10% of full scale | |||
Frequency range: 25 MHz ... 1 GHz |
E = < 0.1 V/m | E = 1 V/m | E = 3 V/m |
Stand alone | N/A | N/A | N/A |
With STL90 | N/A | N/A | 500 V/div |
Mechanical | |
Size exclusive holster | 60 x 130m x 260 mm (2.4 x 5.1 x 10.2 inches) |
Size inclusive holster | 65 x 140 x 275 mm (2.5 x 5.5 x 10.8 inches) |
Weight exclusive holster | 1.5 kg (3.3 lbs) |
Weight inclusive holster | 1.8 kg (4.0 lbs) |
Safety
Designed to Category III per IEC 1010 approved for 600V measurements on industrial power distribution systems.
Overload protection on INPUT A or INPUT B | 300 Vrms |
Overload protection on EXTernal input | 300 Vrms |
Surge Protection | 4 kV per IEC 664 and ANSI/IEEE C62.41 test method |
Maximum Isolation to Earth | 600 Vrms from any terminal |
Optical Interface | Optically Isolated to 600 Vrms |