Fluke Biomedical 451P-RYR Radiation Meter
Condition: Refurbished / Calibrated
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- Fluke Biomedical 451P-RYR Radiation Meter (BC# 43342-L/T*)
- User Manual On CD-ROM
- Carrying Case (G)
Fluke Biomedical 451P-RYR Ion Chamber Survey Meter
Pressurized µR Ion Chamber Survey Meter
The 451P state-of-the-art ion chamber survey meter is a handheld battery operated unit designed for use in both rugged and normal environments. The 451P is a pressurized ion chamber for μR resolution. The 451P auto-ranges and measures radiation rate and accumulated dose from various radiation sources (beta, x-ray and gamma). The ion chamber detector allows for a fast response time to radiation from leakage, scatter beams, and pinholes. Additionally, the low-noise chamber bias supply provides for fast background-settling time.
The digital display features an analog bar graph, 2.5 digit readout, low battery indicator, freeze (peak hold) mode indicator and an automatic backlight function. User controls consist of an ON/OFF button and a MODE button. The case is constructed of lightweight, high strength materials and is sealed against moisture.
The RS-232 interface can be connected directly to a computer for use with the Excel add-in for Windows (451EXL), enhancing the functionality of the instrument. This software allows for data retrieval, user parameter selection and provides a virtual instrument display with audible and visual alarm indication.
Features:
- High µR sensitivity measurement of rate and dose simultaneously
- Records peak rate using “Freeze Mode”
- Auto-ranging and auto-zeroing
- RS-232 communications interface with optional Windows-based Excel add-in for data logging
- Ergonomic, anti-fatigue handle with replaceable grip, wrist strap and tripod mount
- Easily-accessible battery door (operated by two 9-volt alkaline batteries) on the outside of the bottom case
- Programmable flashing LCD display
Specifications:
Radiation detected | Beta: > 1 MeV Gamma: > 25 keV |
Operating ranges, response time | 0 μR/h to 500 μR/h (5 sec) 0 mR/h to 5 mR/h (2 sec) 0 mR/h to 50 mR/h (1.8 sec) 0 mR/h to 500 mR/h (1.8 sec) 0 R/h to 5 R/h (1.8 sec) |
Accuracy | Within 10 % of readings between 10 % and 100 % of full scale indication on any range, exclusive of energy response |
Detector | Chamber: 230 CC Pressurized ionization chamber to 8 atmospheres or
125 psi Controls: ON/OFF and MODE |
Automatic features | Auto-zeroing, auto-ranging, and auto-backlight |
Warm-up time | Less than one minute for initial operation when the instrument is in temperature equilibrium with the surrounding area, typical. (About four minutes for readings if less than 20 μR/h in a 10 μR/h or less background) |
Display LCD analog/ digital with backlight | Analog: 100 element bar graph 6.4 cm long. Bar graph is divided into
5 major segments, each labeled with the appropriate value for the range
of the instrument Digital: 2.5 digit display is followed by a significant zero digit depending on the operating range of the instrument. The units of measurement are indicated on the display at all times. Digits are 6.4 mm (0.25 in) high. Low battery and freeze indicators are also provided on the display |
Modes | Integrate mode: Operates continuously 30 seconds after the
instrument has been turned on. Integration is performed even if the
instrument is displaying in mR/h or R/h Freeze mode: Will place a tick mark on the bar graph display to hold on the peak displayed value. The unit will continue to read and display current radiation values |
Environmental | Temperature range: Relative Humidity: Geotropism: |
Typical energy dependence | Nitrogen gamma rays are 110 % to 120 % of indicated readings as determined at the University of Lowell |
Power requirements | Two 9 V alkaline, 200 hours operation |
Dimensions (WxDxH) | 10 cm x 20 cm x 15 cm (4 in x 8 in x 6 in) |
Weight | 1.07 kg (2.4 lb) |