Fluke ESA601 110 VAC Electrical Safety Analyzer
Condition: Refurbished
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- Fluke ESA601 Electrical Safety Analyzer (BC# 40128-L/T*)
- (2) Fluke 1000V Hard Point Test Leads
- Power Cord
- RS232 PC Interface Cable
- Hard Copy User Manual
- Carrying Case (G)
Fluke ESA601 Electrical Safety Analyzer
ESA601 Electrical Safety Analyzer tests medical equipment to both US and international standards. Users simply flip a switch to change between AAMI or IEC electrical safety testing load. The US version includes overlays in AAMI or IEC nomenclature so technicians use the terms that are most familiar to them. Multiple language overlays, outlets, and power cords are available for convenient use in many countries.
Ten applied part connections allow for lead-toground (patient), lead-to-lead (patient auxiliary), and lead isolation (mains on applied part) leakage testing of equipment with multiple applied parts. Designed for on-the-go testing, the portable analyzer is lightweight and compact and comes with a sturdy handle for easy carrying.
Key features
- Selectable AAMI or IEC test loads
- Ten applied parts-lead connectors
- 90 V (min) to 264 V (max) autoswitching power supply
- Dual-lead leakage and dual-lead voltage tests
- Easy-to-read display
- Compact and portable
- Ansur plug-in software available to automate testing and document results
- Multiple outlets and power cords for compatibility in multiple countries
- Overlays in English, German, French, and Italian
- Overlay for USA version with either IEC or AAMI nomenclature
- RS-232 serial port for PC control and printing
Specifications:
Power | |
Mains power operating range | 90 min to 264 max V ac (47 Hz to 63 Hz), autoswitching |
Power ratings | 16 A at 264 V max |
Mains inlet | The instrument uses a standard IEC 60320-1/C20 mains inlet rated at 16 A and 250 V for class-1 equipment in cold conditions |
Voltage measurements | |
Voltage measurements | Yes |
Display units | V |
Display resolution | 1 V |
Range (mains voltage) | 90 V to 264 V true RMS |
Range (accessible voltage) | 0 V to 264 V true RMS |
Accuracy | ± 2 % of reading ± 2 V |
Frequency response | DC to 1000 Hz (-3 dB point) |
Crest factor | < 3 |
DC input impedance | 1 MΩ |
Earth-resistance measurements | |
Autoranging | Yes |
Display units | Ω |
Display resolution | 0.001 Ω |
Range | 0 Ω to 1.999 Ω |
Accuracy | ± 2 % of reading ± 5 MΩ |
Current source amplitude | 1 A DC (± 10 %) |
Insulation measurements | |
Autoranging | Yes |
Display units | MΩ |
Display resolution | 0.1 MΩ |
Range | 0.5 M to 100 MΩ |
Accuracy | 0.5 MΩ to 20 MΩ, ± 2 % of reading, ± 200 kΩ; above 20 MΩ, ± 5 % of reading, ± 200 kΩ |
Voltage source amplitude | 500 VDC (± 10 %) |
VDE differential current | |
Autoranging | Yes |
Display units | µA |
Display resolution | 10 µA |
Range | 10 µA to 10000 µA |
Accuracy | ± 2 % of full scale |
Leakage-current measure- ments | |
Autoranging | Yes |
Display units | µA |
Display resolution | 1 µA |
Configuration | RMS current flowing through the ANSI/AAMI ES1 1993 or IEC60601-1 test load |
Measurement range | 0 µA to 8000 µA true RMS |
Accuracy | ± 1 % of reading ( ± 2 µA) @ dc and 25 Hz to 1000 Hz*; ± 2.5 % of reading (± 2 µA) 1 kHz to 200 kHz* |
Measururing instrument frequency response | DC to 1 MHz (-3 dB) |
Crest factor | < 3 |
Input impedance | Per figure 15 of IEC601-1 or AAMI ES 1 |
Temperature | |
Operating | 10 °C to 40 °C (50 °F to 104 °F) |
Storage | -25 °C to 50 °C (-13 °F to 122 °F) |
Maximum Humidity | 80 % relative humidity up to 31 °C (88 °F), decreasing linearly to 50 % relative humidity at 40 °C (104 °F) |
Dimensions (WxDxH) | 21.1 cm 24 cm x 7.6 cm (8.2 in x 9.8 in x 3 in) |
Weight | 2.4 kg (5.2 lb) |
For full Fluke ESA601 product specifications, please click here: Fluke ESA601