The Model i400 Is an AC Current Clamp that outpus 1 mA/A via safety shrouded bana plugs; it is designed to extned the measuring capability of an ac current meter to 400 A
Instrument Compatibility
The i400 is compatible with any Fluke Multimeter or any other current measurement device that has the following features:
Specifications:
For full Fluke i400 product specifications, please click here: Fluke i400
The Model i400 Is an AC Current Clamp that outpus 1 mA/A via safety shrouded bana plugs; it is designed to extned the measuring capability of an ac current meter to 400 A
Instrument Compatibility
The i400 is compatible with any Fluke Multimeter or any other current measurement device that has the following features:
- 20 mA ac or greater current range
- Banana inputs
- Input accuracy of 2 % or better to take full advantage of the accuracy of the Current Clamp
- Input impedance of < 10 ?
Specifications:
Electrical Specifications | |
Reference Conditions: | 23 ± 5 °C, 20 to 75 % RH; conductor centered in jaw opening; no dc component; no adjacent conductor |
Measurement Range: | 1 A to 400 A ac rms |
Output | 1 mA/A |
Accuracy | 2 % + 0.06 A, 45 Hz to 400 Hz |
Typical Bandwidth: | 5 Hz to 20 kHz |
Working Voltage: | 1000 V ac rms, in compliance with EN61010 |
Common Mode Voltage: | 1000 V ac rms from earth ground, in compliance with EN61010 |
Load Impedance | < 10 ? |
Maximum Non-Destructive Current | 1000 A |
Duty Cycle: | 1 A to 400 A continuous |
Influence of Adjacent Conductor: | < 7.5 mA/A |
Influence of Conductor Position in Jaw Opening: ± | ± 1.0 % of reading + 0.05 A |
Safety Specifications | |
Category Rating: | CAT III 1000 V and CAT IV 600 V per EN61010-1, Pollution Degree 2 IEC 61010-02-032 |
EMC: | EN 61326-1, FCC for emission and immunity ): Tested to US and Canadian standards for compliance to UL61010-1 and CAN/CSA C22.2 No. 101.1:2004 P: IEC 61010-1 2nd Edition |
General Specifications | |
Output Cable Length: | 1.5M |
Maximum Conductor Size: | 32 mm |
Storage Temperature: - | e: -20 °C to 60 °C |
Operating Temperature: | 0 °C to 50 °C |
Relative Humidity: | 10 °C to 30 °C: 95 % 30 °C to 40 °C: 75 % 40 °C to 50 °C: 45 % |
Temperature Coefficient: | 0.01 X (specified accuracy)/ °C (< 18 °C or > 28 °C) |
Altitude: | Operating: 2000 m; Non-operating: 12000 m |
Dimensions: | 150 x 70 x 30 mm |
Weight: | 114 g |