Fluke Ti200 9Hz 200 x 150 Infrared Thermal Imager
$0.00
Availability:
Out of stock
SKU
Ti56
Condition: Refurbished / Calibrated
Warranty: 90 Day Exchange
Shipping: USA Only
Request a Quote for
- Fluke Ti200 Thermal Imager (BC# 21844)
- Fluke TiSBC3B Smart Battery Charger 3B
- HDMI Cable
- Kingston Micro SD Adapter
- Kingston 4GB Micro SD Card
- (2) Battery Packs
- AC Adapter/Charger w/ (3) International Adapters
- USB PC Interface Cable
- User Manual On CD-ROM
- Carrying Case w/ Strap
Due to strict commerce control regulations, AAATesters does not ship or export Thermal Imagers to any countries outside of the United States. |
International customers, please note that we cannot complete any order that includes a Thermal Imager product. AAATesters cannot complete any sale where the intent may be that a Thermal Imager product may be exported internationally by the end user. |
All customers that are purchasing Thermal Imager products from AAATesters will be required to complete a BIS-711 end use agreement form to ensure that the Thermal Imager product will not be exported internationally. |
Fluke Ti200 Infrared Thermal Imaging Camera
- Get an in-focus image like never before with a touch of a button. LaserSharp® Auto Focus, exclusive to Fluke, uses a built-in laser distance meter that calculates and displays the distance from your designated target with pinpoint accuracy
- Save Reporting Time. Make better decisions faster than before. Organize your measurements by asset in one location with EquipmentLogTM history
- Brilliantly detailed quality images. Pixel for pixel the best spatial resolution available1
- Precisely blended visual and infrared images with crucial details to assist in identifying potential problemsラIR-Fusion® technology with AutoBlendTM mode
- Standard and radiometric video recording and video streaming
- Text and voice recording/annotation allows you to save additional details to image files
- See the details you need with interchangeable smart lensesラ2x and 4x telephoto and wide angleラno calibration required
LaserSharp® Auto Focus, uses a built-in laser distance meter that calculates the distance to your designated target with pinpoint accuracy.
Specifications:
Key features | |
IFOV with standard lens (spatial resolution) | 2.09 mRad, D:S 477:1 |
Detector resolution | 200 x 150 (30,000 pixels) |
Field of view | 24 °H x 17 °V |
Minimum focus distance | 15 cm (approx. 6 in) |
Wireless connectivity | Yes, to PC, iPhone® and iPad® (iOS 4s and later), Androidル 4.3 and up, and WiFi to LAN (where available) |
Fluke ConnectTM app compatible | Yes (where available) |
CNXTM Wireless System | Yes (where available) |
IR-Fusion® technology | Yes |
AutoBlendTM mode | Yes |
Picture-In-Picture (PIP) | Yes |
Ruggedized touchscreen display (capacitive) | 8.9 cm (3.5 in) diagonal landscape color VGA (640 x 480) LCD with backlight |
Rugged, ergonomic design for one-handed use | Yes |
Thermal sensitivity (NETD) | = 0.075 °C at 30 °C target temp (75 mK) |
Level and span | Smooth auto and manual scaling |
Fast auto toggle between manual and auto modes | Yes |
Fast auto-rescale in manual mode | Yes |
Minimum span (in manual mode) | 2.0 °C (3.6 °F) |
Minimum span (in auto mode) | 3.0 °C (5.4 °F) |
Built-in digital camera (visible light) | 5 megapixel industrial performance |
Frame rate | 60 Hz or 9 Hz versions |
Laser pointer | Yes |
LED light (torch) | Yes |
Data storage and image capture | |
Extensive memory options | Removable micro SD memory card, on-board flash memory, save-to-USB flash drive capability, direct download via USB-to-PC connection |
Image capture, review, save mechanism | One-handed image capture, review, and save capability |
File formats | Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); no analysis software required for non-radiometric (.bmp, .jpg and .avi) files |
Memory review | Thumbnail view navigation and review selection |
Software | SmartView® software and Fluke ConnectTMラfull analysis and reporting software |
Export file formats with SmartView® software | BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF |
Voice annotation | 60 seconds maximum recording time per image; reviewable playback on camera |
IR-PhotoNotesTM | Yes |
Video recording | Standard and radiometric |
File formats video | Non-radiometric (MPEG - encoded .AVI) and fully-radiometric (.IS3) |
Streaming video (remote display) | Via HDMI |
Auto capture (temperature and interval) | Yes |
Battery | |
Batteries (field-replaceable, rechargeable) | Two lithium ion smart battery packs with five-segment LED display to show charge level |
Battery life | Four+ hours continuous use per battery pack |
Battery charge time | 2.5 hours to full charge |
Battery charging system | Two-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter |
AC operation | AC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz) |
Power saving | User selectable sleep and power off modes |
Temperature measurement | |
Temperature measurement range (not calibrated below -10 °C) | -20 °C to +650 °C (-4 °F to +1202 °F) |
Accuracy | ± 2 °C or 2 % (at 25 °C nominal, whichever is greater) |
On-screen emissivity correction | Yes (both value and table) |
On-screen reflected background temperature compensation | Yes |
On-screen transmission correction | Yes |
Color palettes | |
Standard palettes | 8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted |
Ultra ContrastTM palettes | 8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra |
General specifications | |
Color alarms (temperature alarms) | High-temperature and low-temperature |
Infrared spectral band | 7.5 µm to 14 µm (long wave) |
Operating temperature | -10 °C to +50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to +50 °C (-4 °F to 122 °F) without batteries |
Relative humidity | 10 % to 95 % non-condensing |
Center-point temperature measurement | Yes |
Spot temperature | Hot and cold spot markers |
User-definable spot markers | 3 user-definable spot markers |
Center box | Expandable-contractible measurement box with MIN-MAX-AVG temp |
Safety | IEC 61010-1: Overvoltage category II, Pollution Degree 2 |
Electromagnetic compatibility | IEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A |
Australian RCM | IEC 61326-1 |
US FCC | CFR 47, Part 15 Subpart B |
Vibration | 0.03 g2/Hz (3.8 g), 2.5 g IEC 68-2-6 |
Shock | 25 g, IEC 68-2-29 |
Drop | Engineered to withstand 2 meter (6.5 feet) drop with standard lens |
Size (H x W x L) | 27.7 cm x 12.2 cm x 16.7 cm (10.9 in x 4.8 in x 6.5 in) |
Weight (battery included) | 1.04 kg (2.3 lb) |
Enclosure rating | IEC 60529: IP54 (protected against dust, limited ingress; protection against water spray from all directions) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
For full FLuke Ti200 specifications, please click here: Fluke TI200