AFL Noyes SMLP 4-4 SM MM Fiber Optic Loss Test Set (OLS4 / OPM4-2D)
Condition: Refurbished
Warranty: 1 YEAR WARRANTY
Shipping: USA & Worldwide
- AFL Noyes OLS 4 SM MM Fiber Optic Laser Source w/ Wave ID (BC# 42410-L/T*)
- SM Source:
- 1310nm
- 1550nm
- MM Source:
- 850nm
- 1300nm
- (2) ST Connectors For Source
- SM Source:
- AFL Noyes OPM 4-2D SM MM Power Meter (BC# 42411-L/T*)
- Power Meter:
- 850nm
- 1300nm
- 1310nm
- 1490nm
- 1550nm
- ST Connector For Power Meter
- Noyes 625 Mandrel
- Noyes 50um Mandrel
- OPM-OLS Quick Reference Guide
- (2) ST-ST SM Fiber Optic Cables
- (2) MM ST-ST Fiber Optic Cables
- Noyes Test Results Manager V1.3.34
- (4) Fiber Wipes
- User Manual On CD-ROM
- Carrying Case
The SMLP4-4 test kit combines the OPM4-2D optical power meter and OLS4 integrated LED and LASER light source and is ideally suited for testing fiber optic networks with hybrid (single-mode and multimode) cables.
The OLS4 features 850/1300 nm LED output from a multimode output port and 1310/1550 nm LASER output from a single-mode output port. Each wavelength may be transmitted individually at CW or with user selectable modulated Tone (SM output). Also, each wavelength may be transmitted with Wave ID. When transmitting with Wave ID, the OLS4 supports transmitting pairs of wavelengths in an alternating pattern. Associated with each operating condition, the designated LED indicator will illuminate to identify the currently enabled operating mode and emitted wavelength(s) along with battery charge status and external power presence. Both output ports are equipped with UCI based removable adapters to allow the output connectors to be inspected and cleaned.
The OPM4-2D features automatic wavelength identification and switching (Wave ID) when used with the OLS4, multiple test Tone detection for fiber identification, and stores optical references for each calibrated wavelength. A large dual-wavelength LCD display with backlight shows measured power [dBm or µW] or insertion loss [dB], calibrated wavelengths [nm], tone signal [Hz], wavelength ID, and estimated remaining battery life. The OPM4-2D optical input port accepts a variety of Noyes thread-on style adapter caps (ordered separately) to meet a wide range of testing requirements.
The OPM4-2D and OLS4 offer long battery life from common AA alkaline batteries. The SMLP4-4 test kit is fully N.I.S.T. traceable.
Features:
- Handheld, rugged, lightweight
- Wave ID (auto identification & switching)
- Dual or single Wave ID, CW, Tone
- 270 Hz, 330 Hz, 1 kHz, 2 kHz Tone
- Large LCD with backlight (OPM4-2D)
- Power measurements in dBm or µW; insertion loss in dB
- Reference power level storage
- Low battery indicator
- Long battery life with 2 x AA alkaline
- Free 50 µm and 62.5 µm mandrels
- Cost-effective, easy to use
- N.I.S.T traceable
Applications:
- Certify multimode and single-mode links per TIA/EIA standards
- Fiber identification prior to splicing
OLS4 Light Source specifications
Optical |
MM Optical Port |
SM Optical Port |
||
Wavelength |
850 ± 30 nm |
1300 -10/+50 nm |
1310 ± 20 nm |
1550 ± 20 nm |
Emitter type |
LED, Class I (IEC 60825 - 1) |
Laser, Class I (FDA 21 CFR 1040.10 and 1040.11, and IEC 60825-1) |
||
Spectral width |
40 nm (typ) |
120 nm (typ) |
5 nm (max) |
5 nm (max) |
Output power |
> - 20 dBm, 62.5 µm multimode |
0 dBm, 9 µm single-mode |
||
Output Stability |
± 0.1 dB over 8 hours |
± 0.05 dB over 1 hour (after 15 min. warm-up) |
||
General |
||||
Power |
2 x AA batteries, optional AC adapter |
|||
Battery life |
Typical 30 hours, minimum 20 hours |
Typical 72 hours, minimum 40 hours |
||
Available adapters |
SC FC, ST, LC |
|||
Operating temperature |
-10 to 50°C, 90% RH (non-condensing) |
|||
Storage temperature |
-30 to 60°C, 90% RH (non-condensing) |
|||
Size (H x W x D) |
14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in) |
|||
Weight |
0.29 kg (0.65 lb) |
OPM4-2D specifications
Optical |
OPM4-2D |
Calibrated wavelengths |
850, 1300,1310, 1550 nm |
Detector type |
Germanium (Ge) |
Measurement range |
+6 to -60 dBm |
Tone detect range |
+6 to -50 dBm +6 to -45 for 850 nm |
Wavelength ID range |
+6 to -50 dBm +6 to -45 dBm for 850 nm |
Accuracy* |
± 0.25 dB |
Resolution |
0.01 dB |
Measurement units |
dB, dBm, µW |
General |
|
Power |
2 x AA batteries |
Battery life |
300 hours |
Operating temperature |
-10 to 50°C, 90% RH (non-condensing) |
Storage temperature |
-30 to 60°C, 90% RH (non-condensing) |
Size (H x W x D) |
14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in) |
Weight |
0.26 kg (0.58 lb) |
For full Noyes SMLP 4-4 product specifications, please click here: Noyes SMLP 4-4