Anritsu MS2090A 9 GHz Field Master Pro Handheld Spectrum Analyzer
Anritsu is proud to introduce the world’s most advanced handheld spectrum analyzer with real-time spectrum analysis capability. With frequency coverage up to 54 GHz, the new Field Master Pro™ MS2090A completely redefines the standards for portable handheld analyzers, setting another new industry benchmark for performance and accuracy. The new MS2090A is the culmination of over 60 years of microwave test and measurement equipment development, using the very latest technologies to deliver accuracy and precision in measurements previously reserved only for benchtop instruments.
Features:
- 5GNR FDD and TDD Analyzer
- Real-Time Spectrum Analyzer
- LTE FDD and TDD Analyzer
- WCDMA FDD Analyzer
- Spectrogram
- Zero Span IF Output
- Gated Sweep
- IQ Waveform Capture/Streaming
- Pulse Profile Measurements
- AM/FM Audio Demodulation
- Multi-language Support
- Electromagnetic Field (EMF) Measurements
- EIRP
- Field Strength
- Occupied Bandwidth
- Channel Power
- Adjacent Channel Power
- Spectral Emissions Mask
- Signal Strength and RSSI
- Carrier Aggregation
- Carrier-to-Interference
- Channel Scanner
Specifications:
| Frequency | Frequency: 9 kHz to 9 GHz Tuning Resolution: 1 Hz Span: 10 Hz to max frequency, Zero Span Frequency Reference: Internal, GNSS, External Internal Frequency Reference: Aging: ± 1.0 x 10 –6 per 10 years Accuracy: ±3.0 x 10–7 (–10 °C to 55 °C) plus aging External Frequency Reference: 10 MHz, -10 dBm to +10 dBm |
| Bandwidth | Analysis Bandwidth: 22 MHz (standard), 55 MHz (Option 103), 120 MHz
(Option 104), 150 MHz (Option 105) RTSA Bandwidth: 22 MHz (standard), 55 MHz (Option 103), 120 MHz (Option 104), 150 MHz (Option 105) Resolution Bandwidth (RBW): 1 Hz to 10 MHz (in RTSA, minimum RBW varies by span, max is 40 MHz), 1 Hz to 40 MHz in zero span RBW Selectivity: 4:1 nominal (–60 dB / –3 dB) Video Bandwidth (VBW): 0.1 Hz to 10 MHz, 1 Hz to 40 MHz in zero span CISPR Bandwidth: Resolution bandwidth when using Quasi-Peak marker function: 200 Hz, 9 kHz, and 120 kHz VBW/Average Type: Linear/Log |
| Sweep | Manual Sweep: Maximum sweep time is 3600 s (1 hour) Sweep Points: 10 to 10,001 (1001 in zero span) Sweep Rate (non-zero span): 40 GHz/s typical (full span, RBW = VBW = 3 MHz) |
| Zero Span | Sweep Time: 60 ns to 3600 s in zero span Sweep Time Accuracy: ±2 % in zero span |
| Spectral Purity - SSB Phase Noise | 10 kHz: –106 dBc/Hz 100 kHz: –110 dBc/Hz 1 MHz: –116 dBc/Hz 10 MHz: –129 dBc/Hz |
| Spurs | Manual Sweep: Maximum sweep time is 3600 s (1 hour) Sweep Points: 10 to 10,001 (1001 in zero span) Sweep Rate (non-zero span): 40 GHz/s typical (full span, RBW = VBW = 3 MHz) |
| Amplitude Ranges | Dynamic Range: >106 dB minimum at 2.4 GHz, 2/3
(TOI-DANL) in 1 Hz RBW Measurement Range: DANL to +30 dBm Display Range: 1 to 15 dB/div in 1 dB steps, ten divisions displayed Reference Level Range: –150 dBm to +30 dBm Attenuator Resolution: 0 to 65 dB, 5 dB steps Reference Level Offset: 99.9 dB external loss to 99.9 dB external gain Maximum Continuous Input: +30 dBm peak typical, ± 50 VDC (≥ 10 dB attenuation) +23 dBm peak typical, ± 50 VDC (< 10 dB attenuation) +10 dBm peak typical, ± 50 VDC (preamp = On) |
| Smart Measurements | Field Strength: Measures field strength (dBm/m
2 , dBW/m2, dBV/m, dBmV/m, dBμV/m, V/m, W/m2 , W/cm 2, A/m) with antenna
gain vs. frequency plot Channel Power: Measures the total power and power spectral density within a specified bandwidth Occupied Bandwidth: Measures the 99 % to 1 % power channel of a signal Adjacent Channel Power: Measures the power in two upper and two lower adjacent channels Spectral Emission Mask: Standards based limits for wireless emissions Carrier-to-Interference (C/I): Measures the ratio of power (dB) in an RF carrier to the interference power in the channel Burst Power Average: Measures average power between two time markers in zero span Total Harmonic Distortion (THD): Measures THD of seven harmonics relative to fundamental frequency |
| Setup Parameters | Frequency: Center/Start/Stop Frequency, Frequency Step, Frequency
Offset, Gestures Span: Span (Manual/Increment 1, 2, 5) Full Span, Last Span, Zero Span Amplitude: Reference Level (Manual/Auto and Offset), Scale/Division, Y-Axis Unit (dBm, dBW, dBV, dBmV, dBμV, dBA, V,W, A), Preamp (On/Off), Attenuation (Auto/Manual), Attenuation Level, Impedance (50 Ω, 75 Ω, other), Custom IMP Loss, Field Strength, Gestures Bandwidth: RBW/VBW (Auto/Manual), VBW Type (Linear/Logarithmic), RBW:VBW Ratio, SPAN:RBW Ratio Sweep: Continuous on/of, Restart, Sweep Once, Sweep to N, Auto/Manual Time, Gated Sweep |
| Spectrogram | Number of Lines: 142 Trace Time/Position Cursor: Up to Six Cursors (display historical trace data by trace position or time) Cursor State: Active, Hold/View, Blank Color Setup: Color Scale Top/Bottom Range, Reference Hue |
| Trace Functions | Traces: Up to Six Traces Trace Type: Clear/Write, Average (2 to 1000), Max Hold, Min Hold, Rolling Average, Rolling Max Hold, Rolling Min Hold Trace Math: T1-T2, T2-T1 (when T5 and T6 are selected) Trace Mode: Active, Hold/View, Blank Detector Type per Trace: Peak, RMS/Avg, Negative, Sample, Normal Trace Normalize: On/Off (defines a 0 dB reference trace) Trace Record: Record live samples with manual tagging to internal or external storage Trace Playback: Play recorded samples from internal or external storage; set playback interval CSV Logging: Record live or playback traces in CSV format for post processing |
| Trigger Functions | Trigger Input Sources (zero span only): Free Run, GNSS/Internal,
Video, External1/2 Trigger Output: Enables GPS 1 PPS output Settings: Timestamps (on/off), Level, Time Interval, Delay, Holdoff, Periodic, Slope (Rising/Falling), Hysteresis |
| Marker Functions | Markers: Up to 12 Markers Marker Measurements: Amplitude, Frequency (swept spectrum display) Amplitude, Time (Zero Span) Marker Mode: Normal, Delta, Fixed Delta Marker: Relative to any Normal or Fixed Marker Marker Function: None, Noise, Frequency Counter (1 Hz, 100 mHz, 10 mHz, 1 mHz resolutions), Quasi-Peak (per CISPR 16-1-1) Marker Trace: Assign Marker to any Trace Peak Search: Peak Search, Next Peak, Next Peak Left, Next Peak Right, Next Point Left, Next Point Right Peak Search Setup: Peak Threshold, Peak Excursion Marker: Mkr Center, Mkr Ref Level Marker Table: Up to 12 Markers Showing Marker, Mode, Function, Trace, Frequency, Amplitude, Delta Frequency & Offset |
| Limit Line Functions | Limit Setup: Upper/Lower, Limit On/Off, Limit Alarm On/Off, Set
Default Limit Line, Frequency Mode (Absolute/Relative) Amplitude Mode
(Absolute/Relative) Limit Line Edit: Frequency, Relative Frequency, Amplitude, Relative Amplitude, Add Point, Add Vertical, Add Gap, Delete Point, Next Point Left/Right Limit Line Move: Center, X-Offset (Hz), Left, Right, Y-Offset, Up, Down, To Marker 1, Marker 1 Offset (dB) Limit Line Envelope: Select Envelope (Upper/Lower), Set Envelope, Envelope Points (2-41), Amplitude Offset, Shape (Square/Slope) |