Tektronix THS3014 kit with accessories

Tektronix THS3014 100MHz Handheld Oscilloscope

Tektronix DSA72504D 25GHz Digital Oscilloscope w/ Opts 2XL/ASM/DJA/MTH/PCE3/PTH1

Tektronix DSA72504D 25GHz Digital Oscilloscope w/ Opts 2XL/ASM/DJA/MTH/PCE3/PTH1

Tektronix DSA72004C Digital Serial Analyzer Oscilloscope w/ Opts 2XL/ASM

$98,099.00
Availability: Out of stock
SKU
11H81

Condition: Refurbished / Calibrated

Warranty: 1 Year Warranty

Request a Quote for

Have Questions or doubts? Submit the following request and expect our detailed quote within 24 hours!

we are commited to win your business!

Tektronix DSA72004C Digital Serial Analyzer Oscilloscope

 

DPO/DSA70000 Series Data Sheet

Features & Benefits

On All Four Channels Simultaneously

20, 16, 12.5, 8, 6, and 4 GHz Bandwidth Models

Up to 50 GS/s Real-Time Sample Rate

Up to 200 Megasamples Record Length with MultiView Zoom™Feature for Quick Navigation

Fastest Waveform Capture Rate with >300,000 wfms/s Maximum perChannel

Digital Serial Analyzer Models with Dedicated Configuration for High-Speed Serial Design and Compliance Testing

Enhanced Bandwidth to the Probe Tip Extended to Support Multiple Bandwidth Steps for Advanced Signal Integrity.

Pinpoint® Triggering, with over 1400 Combinations to Address Virtually Any Triggering Situation

Unique Serial Pattern Triggering up to 3.125 Gbps and 8b/10b StandardProtocol Triggering for Isolation of Pattern Dependent Effects and NRZSerial Test Pattern Triggering up to 6.25 Gbps

Serial Data Analysis and Compliance for PCI Express, Serial ATA,FB-DIMM, SAS, Fiber Channel, IEEE1394b, RapidIO, XAUI, HDMI, DVI,Ethernet, USB 2.0

High-Speed Serial Data Link Analysis for Transmitter Channel Embed orDe-embed and Receiver Equalization Emulation

Most Popular Jitter, Timing, and Eye-Diagram Analysis Package

DDR Memory Bus Analysis

12.1-in. Largest XGA Touch-Screen Display in the Industry

Event Search and Mark to Facilitate the Comprehension of Event Relationships

MyScope® Custom Windows and Right Mouse Click Menus for Exceptional Efficiency

OpenChoice® Software with Microsoft Windows XP OS Enables Built-In Networking and Extended Analysis

 

Applications

Signal Integrity, Jitter, and Timing Analysis

Verification, Debug, and Characterization of Sophisticated Designs

Debugging and Compliance Testing of Serial Data Streams for Telecomand Datacom Industry Standards

Investigation of Transient Phenomena

Spectral Analysis

 

Unmatched Performance for Greater Insight Into Your Design to Get Your Work Done Faster

The DPO70000 and the DSA70000 Series are the new generation of real time digital phosphor oscilloscopes and are the industry’s best solution to the challenging signal integrity issues faced by designers verifying,characterizing, debugging, and testing sophisticated electronic designs.The specialized DSA70000 Series provides a complete and dedicated solution to address the challenges of high-speed serial designs.The family features exceptional performance in signal acquisition and analysis, operational simplicity, and unmatched debugging tools to accelerate your day-to-day tasks. The largest screen in the industry and the intuitive user interface provide easy access to the maximum amount of information.

 

Unmatched Acquisition Performance

Signal Fidelity of Tektronix Oscilloscopes EnsuresConfidence in Your Measurement Results

High bandwidth up to 20 GHz matched across 2, 3, or 4 channels and enabled by Tektronix proprietary DSP enhancement. The user-selectable DSP filter on each channel provides magnitude and phase correction plus bandwidth extension to 20 GHz for more accuratere presentation of extremely fast signals. The DSP filter on each channel can also be switched off to take advantage of true analog bandwidth for applications needed the highest available raw data capture.

Bandwidth Enhance to the probe tip, extended to support bandwidth steps, gives you an oscilloscope with bandwidth adjustable to capture transitions accurately without excess frequencies and noise.

High sample rate on all models, on all channels, to capture more signal details (transients, imperfections, fast edges)50 GS/s on all four channels for the 12.5, 16, and 20 GHz models25 GS/s on all four channels for the 4, 6, and 8 GHz models

Lowest jitter noisefloor and vertical accuracy for very accurate measurements

Longest acquisition of the industry to provide more resolution and longer time sequence

Standard 10 M samples per channel on the DPO70000 Series and 20M on the DSA70000 Series

Optional up to 100 M samples on all four channels for the 4, 6, and 8GHz models

Optional up to 200 M samples on all four channels for the 12.5, 16,and 20 GHz models

Easily manage this deep record length, provide detailed comparison and analysis of multiple waveform segments with the MultiView Zoom™ feature. Automatically scroll through deep records visually, orcreate a math expression to instantly highlight differences

Highest-performance probing solutions with bandwidth enhanced tothe probe tip for differential and single-ended voltage signals, because accurate design verification depends on high-bandwidth access tocritical signals and high-fidelity signal capture

 

Characteristics  
   
DPO/DSA Model 72004  
   
Input Channels 4
Bandwidth (user selectable DSP enhance) 2 settings: 20 GHzand 18 GHz
Rise Time 10% to 90% (typical) 22.5 ps
Rise Time 20% to 80% (typical) 17 ps
Hardware Analog Bandwidth (-3 dB) 16 GHz (typical
DC Gain Accuracy ±2% (of reading)
Bandwidth Limits Depending on instrument model: 19 GHz, 18 GHz, 17 GHz, 16 GHz, 15 GHz, 14 GHz, 13 GHz, 12 GHz, 11 GHz, 10 GHz, 9GHz, 8GHz, 7GHz, 6GHz, 5GHz, 4GHz, 3GHz, 2GHz, 1GHz, or 500MHz
Input coupling DC (50Ω), GND
Input impedence 50Ω±1.5%, 1 MΩwith TCA-1MEG adapter
Input Sensitivity
18 GHz and below
20 GHz and 19 GHz
10 mV/div to 1 V/div (100 mV to 10 V full scale) 20 to 99.5 mV/div and 200 mV/div to 1 V/div
Vertical Resolution 8 bit (11 bit with averaging)
Max Input Voltage, 50Ω <5.5V RMS for≥1 V full scale; also determined by TekConnect accessory
Position range ±5 div
Offset range 10 mV/div: ±450 mV
20 mV/div: ±400 mV
50 mV/div: ±250 mV
100 mV/div: ±4.5 V
200 mV/div: ±4.0 V
500 mV/div: ±2.5 V
1.0 V/div: 0
Offset accuracy 10 mV/div – 99.5 mV/div. ± (0.35% (offset value-position) + 1.5 mV + 1% of full scale)100 mV/div – 1 V/div . ± (0.35% (offset value-position) + 15 mV + 1% of full scale)
 Delay between any two channels (typical) ≤100 ps for any two channels with equal V/div and coupling settings
≤50 ps with BW enhance enabled (BW+)
Channel-to-channel Isolation (Any Two Channels at Equal Vertical Scale Settings) ≥120:1 (for input frequency 0 to 10 GHz)
≥80:1 (for input frequency >10 GHz to 12 GHz.
≥50:1 (for input frequency >12 GHz to 15 GHz)
≥25:1 (for input frequency >15 GHz)
   
Time Base System  
   
DPO/DSA Model 72004  
   
Time Base Range 10 ps/div to 1000 s/div
Time Resolution (in ET/IT mode) 100 fs
Time Base Delay Time Range -5.0 ks to 1.0 ks
Channel-to-channel Deskew Range ±75 ns
Delta Time Measurement Accuracy (typical) Over <100 ns duration; single shot; with signal rise time = 1.2X scope rise time 525fs
Trigger Jitter (RMS) 1ps RMS (typical) with enhanced triggering OFF <100 fsRMS with enhanced triggering ON
Jitter Noise Floor (typical) (With BW+ bandwidth enhance enabled) 400 fs
Time Base Accuracy ±1.5 ppm initial accuracy, aging <1 ppm per year
   
DPO/DSA Model 72004  
   
Sample rates  
   
Real-time mode 1, 2, 3, or 4 channel (max) 50 GS/s
ET/IT Mode (max) 10 TS/s
   
Maximum Record Length per Channel  
   
With Standard Configuration 10 M on all four channels (DPO70000 Series only)
20 M on all four channels (DSA70000 Series only)
With Record Length Opt. 2XL 20 M on all four channels (DPO70000 Series only)
With Record Length Opt. 5XL 50 M on all four channels
With Record Length Opt. 10XL 100 M on all four channel
With Record Length Opt. 20XL 200 M on all four channels
   
Maximum Duration at Highest Real-Time Resolution  
   
DPO/DSA Model 72004  
   
Resolution 20 ps (50 GS/s
Max Duration with Standard Memory .2 ms DPO70000 Series; 0.4 ms for DSA70000 Series
Max Duration with Opt. 2XL 0.4 ms (DPO70000 Series only)
Max Duration with Opt. 5XL 1.0 ms
Max Duration with Opt. 10XL 2.0 ms
Max Duration with Opt. 20XL 4.0 ms
   
Acquisition Modes  
   
Mode  
   
FastAcq Acquisition Mode FastAcq optimizes the instrument for analysis of dynamic signals and capture of infrequent events
Maximum FastAcq Waveform Capture Rate >300,000 wfms/s on all 4 channels simultaneously
Waveform Database Accumulate waveform database providing three-dimensional array of amplitude, time, and counts
Sample Acquire sampled values
Peak Detect Captures narrow glitches at all real-time sampling rates: 1 ns at≤125 MS/s; 1/sample rate at≥250 MS/s
Averaging From 2 to 10,000 waveforms included in average
Envelope From 1 to 2×109waveforms included in min-max envelope
Hi-Res Real-time boxcar averaging reduces random noise and increases resolution
FastFrame™ Acquisition Acquisition memory divided into segments; maximum trigger rate >310,000 waveforms per second. Time of arrival recorded with each event. Frame finder tool helps to visually identify transients.
Roll Mode Up to 10 MS/s with a maximum record length of 40 M
   
   
Pinpoint® Trigger System  
   
DSA Models 70404 / 70604 / 70804 / 71254 / 71604 / 72004  
   
Sensitivity  
Internal DC Coupled 4% of full scale from DC to 50MHz
10% of full scale at 4 GHz
20% of full scale at 8 GHz
50% of full scale at 11 GHz
External (Auxiliary Input) 50Ω 250 mV from DC to 50 MHz, increasing to 350 mV at 1.0 GHz
   
Trigger Characteristics  
   
A Event and Delayed B Event Trigger Types Edge, Glitch, Runt, Width, Transition Time, Time-out, Pattern, State, Setup/Hold, Window—all except Edge, Pattern, and State can be Logic State qualified by up to two channels
Main Trigger Modes Auto, Normal, and Single
Enhanced Triggering User-selectable; it corrects the difference in timing between the trigger path and the acquired data path (it supportsall Pinpoint trigger types on both A- and B-Events except pattern trigger and not available in FastAcq).
Trigger Sequences Main, Delayed by Time, Delayed by Events, Reset by Time, Reset by State, Reset by Transition. All sequences can include separate horizontal delay after the trigger event to position the acquisition window in time.
Communications-related Triggers Support for AMI, HDB3, BnZS, CMI, MLT3 and NRZ encoded communications signals. Select among isolated positive or negative one, zero pulse form or eye patterns as applicable to the standard.
Serial Pattern Trigger Up to 64 bit serial word recognizer, bits specified in binary (high, low, don’t care) or hex format.Trigger on NRZ-encoded data up to 1.25 GBaud.
Serial Pattern TriggerTrigger on 8b/10b-encoded data from 1.25 to 3.125 GBaud (40 bits)
Clock Recovery System  
   
Clock Recovery Phase Locked Loop Bandwidth Fixed at FBaud/1600
Frequency Range 1.5 MBaud to 3.125 GBaud
Clock Recovery Jitter  (RMS)<0.25% bit period + 2 psRMSfor PRBS data patterns
<0.25% bit period + 1.5 psRMSfor repeating "0011” data pattern
 Tracking/Acquisition Range ±2% of requested baud
Minimum Signal Amplitude needed for Clock Recovery 1 divp-pup to 1.25 Gbaud
1.5 divp-pabove 1.25 Gbaud
Trigger Level Range Internal ±120% of full scale from center of screen
AUX Trigger TekConnect interface: ±5 V
Line Fixed at 0 V
Trigger Coupling DC, AC (attenuates <100 Hz)
HF Rej (attenuates >20 kHz)
LF Rej (attenuates <200 kHz)
Noise Reject (reduces sensitivity)
Trigger Holdoff Range 250 ns min to 12 s max
   
Trigger Modes  
   
Mode  
   
Edge Positive or negative slope on any channel or front panelauxiliary input. Coupling includes DC, AC, noise reject, HFreject, and LF reject.
Glitch Trigger on or reject glitches of positive, negative, or either polarity. Minimum glitch width is downto150ps (typical) with rearm time of 300 ps
Width Trigger on width of positive or negative pulse either within orout of selectable time limits (down to 150 ps).
Runt Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again. Event can be time or logic qualified.
Time-Out Trigger on an event which remains high, low, or either, for aspecified time period. Selectable from 300 ps.
Transition Trigger on pulse edge rates that are faster or slower thanspecified. Slope may be positive, negative, or either.
Setup/Hold Trigger on violations of both setup time and hold time between clock and data present on any two input channels.
Pattern Trigger when pattern goes false or stays true for specified period of time. Pattern (AND, OR, NAND, NOR) specified for four input channels defined as high, low, or don’t care.
State Any logical pattern of channels (1, 2, 3) clocked by edge on channel 4. Trigger on rising or falling clock edge.
Window Trigger on an event that enters or exits a window defined by two user-adjustable thresholds. Event can be time or logic qualified.
Trigger Delay by Time 3.2 ns to 3Ms
Trigger Delay by Events 1 to 2G events
Comm Standard feature on the DSA70000, provided as part of Opt.MTH on the DPO70000 Series. Support for AMI, HDB3,BnZS, CMI, MLT3 and NRZ encoded signals.
Serial Pattern Trigger on NRZ-encoded data up to 3.125 Gbaud; above 1.25 Gbaud requires 8b/10b encoded data. Extended with pattern lock triggering to capture repeated acquisitions of long serial test patterns up to 6.25Gbps.
   
Search and Mark Events  
   
Event  
   
Basic Mark any events and document waveforms. Search positive, negative slopes or both on any channels. Event table summarizes all found events. All events are time stamped in reference to trigger position. Users can choose to stop acquisitions when an event is found.
Advanced Search glitches or runts, as well as transition rate, pulse width, setup and hold, time-out, window violations, or find any logic or state pattern on any number of channels. Search DDR read or write bursts with Opt. DDRA.
   
Waveform Measurements  
   
Measurement  
   
AutomaticMeasurements 53, of which 8 can be displayed on screen at any one time; measurement statistics, user-definable reference levels, measurement within gates isolating the specific occurrence within an acquisition to take measurements on.
Amplitude Related  Amplitude, High, Low, Maximum, Minimum, Peak-to-Peak,Mean, Cycle Mean, RMS, Cycle RMS, Positive Overshoot,Negative Overshoot
Time Related Rise Time, Fall Time, Positive Width, Negative Width, Positive Duty Cycle, Negative Duty Cycle, Period, Frequency,Delay
Combination Area, Cycle Area, Phase, Burst Width
Histogram Related Waveform Count, Hits in Box, Peak Hits, Median, Maximum, Minimum, Peak-to-Peak, Mean (μ), Standard Deviation (sigma),μ+1sigma, μ+2sigma, μ+3sigma
Eye Pattern Related Extinction Ratio (absolute, %, dB), Eye Height, Eye Width, Eye Top, Eye Base, Crossing %, Jitter (p-p,RMS, 6sigma), Noise (p-p, RMS), Signal/Noise Ratio, Cycle Distortion, Q-Factor
   
Waveform Processing/Math  
   
Processing Type  
   
Arithmetic Add, Subtract, Multiply, Divide Waveforms and Scalars
AlgebraicExpressions Define extensive algebraic expressions including Waveforms, Scalars, User-adjustable Variables and Results of Parametric Measurements e.g. (Integral (CH.1–Mean (CH.1))×1.414×VAR1)
Math Functions Average, Invert, Integrate, Differentiate, Square Root,Exponential, Log10, Loge, Abs, Ceiling, Floor, Min, Max, Sin,Cos, Tan, ASin, ACos, ATan, Sinh, Cosh, Tanh
Relational Boolean result of comparison >, <,≥,≤,==,!=
Frequency Domain Functions Spectral Magnitude and Phase, Real and Imaginary Spectra
Vertical Units Magnitude: Linear, dB, dBm
Phase: Degrees, radians, group delay
IRE and mV units
Window Functions  Rectangular, Hamming, Hanning, Kaiser-Bessel, Blackman-Harris, Gaussian, Flattop2, Tek Exponential
Waveform Definition As an arbitrary math expression
Filtering Functions User-definable filters. Users specify a file containing the coefficients of the filter. Several filter files provided.
Mask Function A function that generates a Waveform Database pix map from a sample waveform. Sample count can be defined.
   
Display Characteristics  
   
Characteristic  
   
Display Type Liquid crystal active-matrix color display
Display Size Diagonal: 307.3 mm (12.1 in.)
Display Resolution XGA 1024 horizontal × 768 vertical pixels
Waveform Styles Vectors, Dots, Variable Persistence, Infinite Persistence
Color Palettes Normal, Green, Gray, Temperature, Spectral, and User-defined
Display Format YT, XY
   
Computer System and Peripherals  
   
Item  
   
Operating System Windows XP 
CPU Intel Pentium 4, 3.4-GHz processor
PC System Memory 2 GB 
Hard Disk Drive Rear-panel, removable hard disk drive, 80 GB capacity
CD-R/W Drive Front-panel CD-R/W drive with CD creation software application
DVD Drive Read Only
Mouse Optical wheel mouse, USB interface
Keyboard USB Interface
   
Input/Output Ports  
   
Front Panel Port  
   
Aux Triggered Input See trigger specifications
Recovered Clock SMA connector, ≤1.25 Gbps, Output swing ≥130 mVp-pinto 50Ω at 1.25 Gbps. Requires Opt. PTH or Opt. MTH toenable on DPO70000, standard on DSA70000.
Recovered Data SMA connector, ≤1.25 Gbps, Output swing of 1010 repeating pattern 200 mV into 50Ωat 1.25 Gbps. Requires Opt.PTH or Opt. MTH to enable on DPO70000, standard on DSA70000.
DC Probe Calibration Output BNC connector, ±10 V DC for DC probe calibration. (Signal available only during probe calibration.)
Fast Edge Output SMA connector provides fast edge signal. 1 kHz ±20%;810 mV (base to top) ±20% into ≥10 kΩ load; 440 mV ±20% into a 50Ω load.
Aux Trigger Output BNC connector, provides a TTL-compatible, polarity-switchable pulse when the oscilloscope triggers.
USB 2.0 Port One in front, four on back. Allows connection ordisconnection of USB keyboard, mouse, or storage devicewhile oscilloscope is on.
   
Rear Panel Port  
   
External Time BaseReference  . In BNC connector; allows timebase system to phase lock to external 10/100 MHz reference. Optimized (by using asoftware switch) for either a highly stable clock or tracking mode
Time BaseReference Out BNC connector; provides TTL-compatible output of internal 10 MHz reference oscillator
AUX Trigger Output  BNC connector, 0 to 3 V; default output is A-Event Trigger low true
Parallel Port IEEE 1284, DB-25 connector
Audio Ports Miniature phone jacks for stereo microphone input and stereoline output.
USB 2.0 Ports Four in back. Allow connection or disconnection of USB keyboard, mouse, or storage device while oscilloscope power is on.
Keyboard Port PS/2 compatible
Mouse PS/2 compatible
LAN Port RJ-45 connector, supports 10Base-T, 100Base-T, and 1000Base-T
Serial Port DB-9 COM1 port
Windows Video Port  15 pin D-sub connector on the rear panel; connects a second monitor to use dual-monitor display mode allowing analysis results and plots to be viewed along with the oscilloscope display. Video is DDC2B compliant.
GPIB Port IEEE 488.2 standard
Scope XGA VideoPort 15 pin D-sub connector on the rear panel, video is IBM XGA compatible. Connects to show the oscilloscope display, including live waveforms on an external monitor or projector.The primary Windows desktop can also be displayed on an external monitor using this port.
TekLink™ Proprietary interface for connecting multiple Tektronix instruments
Power 100 to 240VRMS, ±10%, 50/60 Hz; 115 VRMS ±10%, <870 Watts, 400 Hz; CAT II, <1100 VA typical
For full Tektronix DSA72004C Oscilloscope product specifications, please click here: DSA72004C

Tektronix DSA72004C Digital Serial Analyzer Oscilloscope

Installed Options:
- 2XL: 20M Samples/ch
- ASM: Advanced Event Search and Mark

Includes Accessories As Listed!

BC# -L/T*

Tektronix DSA72004C DSA-72004C Oscilloscope Models On Sale Warranty Calibration Backed by The Best Service and Lowest Prices in the Industry.

  • Tektronix DSA72004C Digital Serial Analyzer Oscilloscope w/ Options: (BC# -L/T* )
    • Installed Options:
      • 2XL: 20M Samples/ch
      • ASM: Advanced Event Search and Mark
  • Power Cord
  • User Manual on CD